This appliance does not need an earth connection as it is double insulated. (Class II)

CONNECT THE LIVE SUPPLY TO 

L

 TERMINAL

CONNECT THE NEUTRAL TO ONE OF THE 

N

 TERMINALS - SEE BELOW:

TF200

Connect Mains Neutral to:

N3

 for High Speed

N2

 for Medium Speed

N1 

for Low Speed

Maintenance and service

Switch off mains supply before making any 

electrical connections. If in any doubt contact 

a qualified electrician.

For any maintenance operation which is not simply 

cleaning the exterior of the extractor fan, the casing 

assembly must be taken out of its housing as indicated 

in point 1 of the installation instructions. Then the two 

reducer tubes (V) must be removed. (see Fig.14)

To remove casing assembly:

1. Loosen 8 screws (X)

2. Gently separate reduce cones (V) 

  from chassis.

The motor, fan and all the components must be 

regularly inspected to ensure that they are not dirty 

nor have suffered any damage. The frequency will 

depend on its operating conditions.

During the maintenance sessions remove any dirt 

collected on the fan blades and the internal parts of 

the frame to avoid any imbalance in operation which 

would lead to a reduction of the aerodynamic qualities 

and possible damage to the motor.

Never submerge the appliance in water or in any 

liquid. Do not use solvents to clean the appliance 

The motor bearings need no maintenance.

X

V

X

V

X

Fig.14

RATING/ SPECIFICATIONS

For all electrical power and IP ratings refer to the fan 

rating and wiring label.

IMPORTANT

Switch off mains supply before making any 

electrical connections. If in any doubt contact a 

qualified electrician. The appliance is not intended 

for use by young children or infirm persons without

supervision.

Young children should be supervised to ensure that 

they do not play with the appliance.

Precautions must be taken to avoid the backflow

of gases into the room from the open

flue of gas or other open-fire appliances

when mounted in outside windows or walls.

N2

N1

N2

N1

N2

N1

L

N

L

L

L

L

L

L

N

N

N

N3 Speed 3 MF200S only 

N2 Speed 2
N1 Speed 1
Live
DO NOT USE
DO NOT USE

....

....

....

N3

N2
N1

L

DO NOT

USE

DO NOT

USE

TF100/ 125/ 150 mm

Summary of Contents for TF100

Page 1: ...tion electrical connections and adjustments must be performed according to the local regulations by a qualified person Failure to comply with these instructions will void the warranty In the event of incorrect installation the Manufacturer will not accept responsibility for the material or personal damage which may occur Before beginning the installation check that The fan is not distorted or dama...

Page 2: ...ble insulated appliance The extractor must be connected permanently to by a fixed installation cable secured in fixed channeling Flex of two conductor wires of minimum section 1mmÇ and maximum 1 5mmÇ The 100 125 150mm fans have a two speed motor the 200mm fans have a three speed motor To make the Electrical Connection 1 Loosen the 4 screws 1 K and take off the connection cover M Fig 2 2 Perforate ...

Page 3: ...s During the maintenance sessions remove any dirt collected on the fan blades and the internal parts of the frame to avoid any imbalance in operation which would lead to a reduction of the aerodynamic qualities and possible damage to the motor Never submerge the appliance in water or in any liquid Do not use solvents to clean the appliance The motor bearings need no maintenance X V X V X Fig 14 RA...

Page 4: ...l Art no Fresh TF100 Inline fan 430102 Fresh TF125 Inline fan 430112 Fresh TF150 Inline fan 430122 Fresh TF200 Inline fan 430132 Dimensions mm Size 100 125 150 200 AØ 97 122 147 199 5 BØ 178 178 200 223 C 124 124 138 146 D 298 259 350 300 E 96 96 118 130 F 168 168 192 195 G 120 120 162 100 H 153 5 153 5 178 180 G D A B F H C E ...

Reviews: