MCC
–
Cold / Ambient
US
12/40
3.1.1 Unpacking the front doors (optional)
The front door(s) (1-3) and fixings are placed in a crate during transport.
3.2
Installation and positioning
WARNING
Self-contained Cold units:
Propane refrigerant is highly flammable
. All safety
precautions must be followed.
WARNING
Electric chock
hazard
. Grounding instructions: only connect the appliance to an
alternating current provided by a grounded wall socket, with a mains voltage in
accordance with the information indicated on the data plate of the appliance.
It is the consumer's responsibility to make sure the electrical installation conforms
with current national and local codes and wiring regulations.
Do not use a multi plug or extension cord. Such can result in fire, electrical shock, or
other personal injury.
Failure to follow these instructions can result in death or serious injury.
WARNING
Position the unit on a flat and horizontal surface. A temporally inclined plane of
maximum 5° is allowed.
•
Place the unit level on a sufficiently sturdy floor. Keep the weight of the unit in mind. Use a
levelling instrument to level the unit by
adjusting the unit’s legs.
•
Be sure that the personnel have sufficient room to work with the unit.
•
Keep a distance of at least 6 inch between the back wall and the unit.
•
While positioning, keep the unit out of children’s reach.
•
The unit has a mains plug, and must be connected to a wall socket with the proper mains
voltage. The wall socket must be mounted by a certified electrician.
Cold Units:
•
Do not position a unit near a doorway, a ventilation device or a refrigerator in order to avoid
any
negative effects on the unit’s operation by a cold airflow. The unit is designed for a
maximum draft of 0.65 ft./sec.
•
Do not place into direct sunlight.
•
Be sure that for SS models the ambient temperature remains between 55ºF - 75ºF and that
the relative air humidity remains below 55%. These units have been designed to operate at
climate class Type I.
•
Be sure that for FS models the ambient temperature remains between 55ºF - 80ºF and that
the relative air humidity remains below 60%. These units have been designed to operate at
climate class Type II.
•
Keep the plinth free from any obstacles to ensure ventilation.
•
Remote units: The system must be installed by qualified persons only. Refer to section 1.4.3.
•
Remote units: Fixate the unit to the floor.
Fixings