THE PARAMETER MENU
Page 7
Service Manual Bake Star 3-5-8-10 intelligent form 9123665 rev. 03/2006
SERVICE PARAMETERS
Parameter Function
Description
0
Clear bake programs
Press “+” and confirm with “Yes” to delete all bakingprograms
1
Clear score tap
Erase the score table (not in use)
2
Reset all parameters
Revert all setting to factory default
3
Contrast calibration
Set the contrast
4
Fan time Left
Time in seconds the lower left fan turns to the left
5
Fan time Right
Time in seconds the lower left fan turns to the right
6
Fan 1-time Left
Time in seconds the lower left fan turns to the left in the first bake step
7
Fan 1-time Right
Time in seconds the lower left fan turns to the right in the first bake step
8
Fan S-time Left
In S-mode: running time left
9
Fan S-time Right
In S-mode: running time right
10
Fan S pause
In S-mode: pause between left and right turn
11
Fan S max temp
In S-mode: maximum oven temperature
12
Fan S speed
In S-mode: start up speed
13
Fan off-time
Time in 0.1 sec the fan is powerless during changing of direction
14
Max poweroff temp
Maximum temperature for power-off during cooling down
15
Steam PW
Steam pulse width in milliseconds. Allways in steps of 10ms minus 5ms for 50Hz
systems
16
Steam pause
Pauze in 0.1 sec between steam pulses
17
Stm2 start delay
Steam mode 2 parameters. Time between the closing of the door and the first steam
pulse.
18
Stm2 pulse length
Steam mode 2 parameters. Length of the first pulse.
19
Exh Open time
Exhaust valve openingstime in sec at the end of the bakingstep
20
Cool Stm pls
Cooling down parameters for fast cooling procedure with water
21
Cool Stm tmp
Cooling down parameters for fast cooling procedure with water
22
Cool door tm
Cooling down parameters for fast cooling procedure with water
23
Door open delay
Delay for automatically opening of the door after bakingprocess, also the length of
the beeper
24
Heater TMIN
Half of a heater on/off cycle
25
Heater PMIN
Minimum on or off time for the heating elements in seconds
26
HOG start
No longer active
27
HOG stop
No longer active
28
Preheat cool
Temperature difference when cooling down during the preheat step
29
Temp P
P action of temperature controller
30
Temp I
I action of temperature controller
31
Temp D
D action of temperature controller
Access to the service parameters is achieved in the following way:
From the “OFF” position, enter the code “0440”. Than push “ext. menu”. This is key “5”.
In case the password has been changed and lost, you can use the password 6705167401. This over-
rules the other one
Choose the desired parameter with the “arrow” keys and change with “+” or “-“.
With the key “Clear UPass” it is possible to put the user password back to the default “0000”.
With the key “Chng SPass”, it is possible to change the service password.