PROGRAMMING INSTRUCTIONS
Page 10
Service Manual Bake Basic form 9123763 rev. 03/2017
These models can be recognized at the presence of a
key.)
Service access is achieved by the code
. The keys have to be pushed simultaniously
from the “oven OFF” position.
Choose the desired parameter with the
arrows.
Push to view the setting.
Change the setting with the
arrows.
Push to confirm the setting.
Push for 3 seconds to exit the service menu.
Parameter list for models untill december 2008 (with key)
Nr. Mo-
del
De-
fault
min.
max.
unit
Description
S01 E/P
-
0
1.00.2 -
Software version (not adjustable)
S02 E/P
°C
°C
°F
-
Temperature unit
S03 E/P
24
12
24
hour Clock notation, 12 or 24 hours.
S04 E/P
3
1
10
-
Number of repeating buzzer “beeps”
S05 E/P
2
0
10
sec
Time between the repeating buzzer “beeps”.
S06 E/P
60
0
300
sec
Maximum door open time during loading product.
S07 E/P
10
0
300
sec
Maximum door open time during baking.
S08 E/P
30
0
50
°C
Preheat delta.
S09 E/P
2
0
10
°C
Hystereses temperature controller
S10 E/P
120
0
180
sec
Blower left and right run time.
S11 E/P
12
0
20
sec
Blower pause between switching direction.
S12 E/P
No
No
Yes
-
Demo mode (no heating )
S13 P
Yes
No
Yes
-
Switch off the light when opening the door.
S14 E/P
120
0
240
min
Automatic switch OFF timer when no action.
S15 E/P
No
No
Yes
-
Stay on temperature after bake program finished.
S16 E/P
50
30
260
°C
Cooling down temperature when switching OFF
S17 E/P
No
No
Yes
-
All settings back to factory defaults.
S18 E/P
No
No
Yes
-
Store settings as defaults.
S19 E/P
None None Test
-
Function test I/O.
1=Blower, 2=heating, 3=doorswitch, 4=watervalve
S20 P
No
No
Yes
-
Preheat yes or no
S21 P
0
0
25
-
Number of locked programs.
S22 P
No
No
Yes
-
Erase all baking programs.
S23 P
0.1
0.1
0.4
sec
Steam pulse time.
S24 P
3
0
10
sec
Time between steam pulses.
S25 P
30
0
60
sec
Blower stops after last steampulse (only mode 0)
SERVICE MENU AND SETTINGS -E- AND -P- MODEL 2008