REMOVAL AND REPLACEMENT OF PARTS
Service Manual Cold Deli CD3/4/5 form 9123583 rev.4/2015
Page 10
TEMPERATURE SENSOR
1. Remove the blower plate according to
prior procedure.
2. Loosen the nut securing the sensor and
remove the sensor.
3. Remove the rear panels according prior
procedure.
4. Disconnect the wiring of the sensor on
the thermostat and remove the sensor.
5. Reverse the procedure to install
Note 1
: The sensor wiring will pass through
the polyurethane foam (also known as PUR
or Great Stuff foam), when installing the new
sensor some extra sealant should be applied
to recreate a watertight fit.
Note 2:
when refitting the sensor it is easiest
to guide the wiring of the sensor through
the hole starting in the product area.