REMOVAL AND REPLACEMENT OF PARTS
Service Manual Cold Deli CD3/4/5 form 9123583 rev.4/2015
Page 11
1. Remove the blower plate according to
prior procedure.
2. Remove the four screws that secure the
evaporator plate and remove the plate.
3. Remove the sensor from the evaporator
by gently folding back the metal blades of
the evaporator.
4. Remove the rear panels according prior
procedure.
5. Disconnect the wiring of the sensor on
the thermostat and remove the sensor.
6. Reverse the procedure to install
Note 1
: When removing the evaporator plate
both rear corners of the plate may get stuck
in the corners of the unit, some maneuvering
and guiding by hand should solve this.
Note 2:
The sensor will pass through the
polyurethane foam (also known as PUR or
Greatstuff foam), when installing the new
sensor some extra sealant should be applied
to recreate a watertight fit.
Note 3:
When refitting the sensor it is easiest
to guide the wiring of the sensor through
the opening starting in the product area.
DEFROST SENSOR
Summary of Contents for COLD DELI CD 3 Self
Page 2: ...Page 2 Service Manual Cold Deli CD3 4 5 form 9123583 rev 4 2015...
Page 31: ...EXPLODED VIEWS AND PARTLISTS Page 31 Service Manual Cold Deli CD3 4 5 form 9123583 rev 4 2015...
Page 41: ...EXPLODED VIEWS AND PARTLISTS Page 41 Service Manual Cold Deli CD3 4 5 form 9123583 rev 4 2015...
Page 47: ...EXPLODED VIEWS AND PARTLISTS Page 47 Service Manual Cold Deli CD3 4 5 form 9123583 rev 4 2015...
Page 57: ...EXPLODED VIEWS AND PARTLISTS Page 57 Service Manual Cold Deli CD3 4 5 form 9123583 rev 4 2015...
Page 66: ...Page 66 Service Manual Cold Deli CD3 4 5 form 9123583 rev 4 2015...
Page 67: ...Page 67 Service Manual Cold Deli CD3 4 5 form 9123583 rev 4 2015...