ELECTRICAL TESTS AND SERVICE PROCEDURES
Parameters
CD 3-4
Full Service
CD 5
Full Service
CD 3-4
Self Service
CD 5
Self Service
Standard
value from
supplier
Codes Function
Normal Operation
-
Temperature (set point)
1,5°C
0,5
2°C
0,5C
2°C
Thermostat
r01
Differential
2 K
2 K
2 K
2 K
2 K
r02
Higher setpoint limit
5°C
5°C
6°C
6°C
50°C
r03
Lower setpoint limit
-2,5°C
-2,5°C
-3°C
-3°C
-50°C
r04
Off-set temperature indication
0 K
0 K
0 K
0 K
0 K
r05
Temperature unit (°C/°F)
°C
°C
°C
°C
°C
r09
Correction of the signal from air output
0 K
0 K
0 K
0 K
0 K
r12
start/stop regulation (1/0)
1
1
1
1
1
r13
Night setback value
0 K
0 K
0 K
0 K
0 K
Alarm
A03
Delay temperature alarm
30 min
30 min
30 min
30 min
30 min
A04
Delay door alarm
60 min
60 min
60 min
60 min
60 min
A12
Delay temperature alarm after defrost
90 min
90 min
90 min
90 min
90 min
A13
High alarm limit
10°C
10°C
10°C
10°C
10°C
A14
Low alarm limit
-30°C
-30°C
-30°C
-30°C
-30°C
A37
High alarm limit for condenser
50°C
50°C
50°C
50°C
50°C
Compressor
c01
Min. ON-time compressor
0 min
0 min
0 min
0 min
0 min
c02
Min. OFF-time compressor
3 min
3 min
3 min
3 min
0 min
c05
Time delay second compressor
5 sec
5 sec
5 sec
5 sec
5 sec
c30
Reversed function compressor relay
OFF
OFF
OFF
OFF
OFF
Defrost
d01
Defrost method (0=none / 1=natural)
1
1
1
1
1
d02
Defrost end temperature
4°C
4°C
4°C
4°C
6°C
d03
Defrost interval
4 hours
4 hours
3 hours
3 hours
8 hours
d04
Maximal defrost duration
45 min
45 min
45 min
45 min
45 min
d05
Time delay defrost at start-up
0 min
0 min
0 min
0 min
0 min
d10
Defrost sensor (1=S5, 2=Sair)
1
1
1
1
0
d13
Defrost at start-up
no
no
no
no
no
d18
Max. refrigeration time between two defrosts
4 hours
4 hours
3 hours
3 hours
8 hours
d19
Defrost on demand (20=off)
20 K
20 K
20 K
20 K
2 K
Miscellaneous
o01
Delay of output signals after start-up
5s
5s
5s
5s
5s
o02
Digital input signal (0=not used)
0
0
0
0
0
o05
Access code 1 (0 = not used)
0
0
0
0
0
o06
Sensor type (Pt /PTC/NTC)
PTC
PTC
PTC
PTC
Pt
o15
Display step (yes= 0.5 / no= 0.1)
no
no
no
no
no
o64
Access code (0= not used)
0
0
0
0
0
o65
Copy parameter settings (0 = not used)
0
0
0
0
0
o66
Loading paramater settings
0
0
0
0
0
o67
Replacing factory settings with the present
settings
OFF
OFF
OFF
OFF
OFF
o69
Function Saux sensor (0=not used)
0
0
0
0
0
o70
Function S5 sensor (0=defrost, 1= product)
0
0
0
0
0
o71
Function relay 2 (1=compr./defrost, 2 = alarm
relay)
1
1
1
1
1
Page 25
Service Manual Cold Deli CD3/4/5 form 9123583 rev.4/2015
DANFOSS EKC 102C SETTINGS (PART 1)
Summary of Contents for COLD DELI CD 3 Self
Page 2: ...Page 2 Service Manual Cold Deli CD3 4 5 form 9123583 rev 4 2015...
Page 31: ...EXPLODED VIEWS AND PARTLISTS Page 31 Service Manual Cold Deli CD3 4 5 form 9123583 rev 4 2015...
Page 41: ...EXPLODED VIEWS AND PARTLISTS Page 41 Service Manual Cold Deli CD3 4 5 form 9123583 rev 4 2015...
Page 47: ...EXPLODED VIEWS AND PARTLISTS Page 47 Service Manual Cold Deli CD3 4 5 form 9123583 rev 4 2015...
Page 57: ...EXPLODED VIEWS AND PARTLISTS Page 57 Service Manual Cold Deli CD3 4 5 form 9123583 rev 4 2015...
Page 66: ...Page 66 Service Manual Cold Deli CD3 4 5 form 9123583 rev 4 2015...
Page 67: ...Page 67 Service Manual Cold Deli CD3 4 5 form 9123583 rev 4 2015...