Service Instructions
Page 73
Service Manual Deli Multisserie form 9123560 rev. 09/2017
13
13
13
13
13
13
V5_00_13.bin
Updating systemsoftware (firmware).
Only if needed!!
This software, supplied by Fri-Jado comes in a “zip” file with the version number of the soft-
ware, for example “V5_00_13.zip”. The file needs to be copied on a USB stick. (disk “STORE N
GO (F:)” in the example)
After unpacking it, the folder named “42-I+CPU” needs to be moved or copied to the root of
the USB stick as shown below.
==> Untill software version V5.xx.xx can be used on all boards (with USB port)
==> For software version V6.xx.xx, bootloader version 1.02.02 or higher, is necessary.
More information!
• Please refer to the service manual i-control for the latest parameter lists and more informa-
tion about this controller.
• Also check for the latest software version!
Both can be found on the Fri-Jado website “www.frijado.com” in the distributer area.
How to read out the software version (firmware).
1. Switch ON the unit. (push 3 sec.)
2. Push the <settings> tab.
3. Select “information”
4. Read out the version
How to read out the bootloader version.
1. Disconnect the mains supply.
2. Connect the mains supply.
3. Read out the bootloader version.
Now proceed as follows:
1. Switch OFF the mains supply or pull the mains plug.
2. Connect the usb stick.
3. Switch the power back on or put the mains plug back in. You will see that the controller
detects the software and starts uploading
4. You will be asked to remove the stick and when done the unit switches off. ( the existing
parameters will remain).
5. In case the board has just been put into a unit, it has to be set to the right device
type!!!!!
This has to be done in the service menu. Refer to the previous page.
After unpacking
Move the “42-I+CPU” folder to the root.