GENERAL DESCRIPTION
Picture 1
The Multisserie Internal Condenser
is factory
placed on top of the Multisserie. See the part
above the dashed line.
A “drawer” construction is made to make ac-
cess for service easier.
The condensor has 3 blowers to cool down
the heat exchanger (condenser). These blo-
wers turn on together with the blowers on
the heaters.
The condenser has one blower to force the
fumes out of the the oven (coldflush). It
blows cool air into the oven at point 4 (see
below). Fumes are forced out at point 11
and through a hose into the condenser. The
condensed fluid coming out of the conden-
ser, goes down through a 22mm copper pipe,
followed by a grey hose. This hose must be
hooked into the (customers) drainpipe. The
blower is separately controlled by the oven
controller.
Software description
.
The “coldflush blower” is activated 25 se-
conds before the end of each cooking pro-
gram. This time is determined in the service
parameters. During this time the fumes will
be forced out of the unit. When the door
is opened after the “end” beep, almost no
fume comes out anymore.
The exhaust valve
is not programmable in
the cooking program when an internal con-
denser is installed. The operation of it, is
fixed in the software. During cooking it will
be opened and during cleaning it will be
closed.
11
Multiserie exhaust
Ceiling oven cavity
Drain
Silicon hose
Cold flush blower
Cooling fans
Heat exchanger
Ventilating cap
4
Non-return
valve
Picture 2
Flow overview condenser unit
CONDENSER HOOD