Condenser Hood
Page 96
Service Manual Deli Multisserie form 9123560 rev. 02/2017
The coldflush blower
can also be programmed
in the cooking program. In the last column of
the programming diagram, a certain time can
be given during which the cold flush blower
will be activated. This time is from 0 untill
240 seconds and comes at the
beginning
of a
cooking stage.
For each “flush” a cooking stage need to be
programmed.
Picture 3 gives an overview of the air grids
which must be
prevented from blockage
!
Picture 4 shows all parts in the top of the Mul-
tisserie when the Internal Condenser would
have been removed completely.
1. Tube connection from watersprayers.
2. Wire from one of the doorswitches.
3. Position of the PT1000 sensor in the top.
The other 2 wires are from one of the 3
halogen lamps.
4. Vent. (Fumes outlet)
5. Steam injection pipes and couplings.
6. Chain stretcher.
7. Soap mister. (soap tube is marked with
black tape).
8. Rotor shaft with position switch and sli-
ding ring/contacts for core probe.
9. 2 ceramic terminal blocks for serial connec-
tions of the door switches.
10. Position where the wires from the lower
PT1000 sensor go into the post.
11. Non-return valve.
Picture 3
Flow overview air inlet and outlet
Cold air in
Warm air out
9
8
7
6
5
4
3
2
1
11
10