REMOVAL AND REPLACEMENT OF PARTS
Service Manual Hot Deli HD3/4/5/7 form 9123549 rev.03/2017
Page 30
CHANGING DANFOSS EKC TO ERC THERMOSTAT
The wiring connection numbers 1-4-2-5-13-14 on the Danfoss EKC thermostat are different
than the wiring connections 3L-2-4N-1-9-10 on the ERC thermostat. keep this in mind when
you change the EKC for the ERC thermostat. See also the drawing below.
For adjusting instructions and parameter settings see electrical tests on pages
34 - 35 and 38.