REMOVAL AND REPLACEMENT OF PARTS
Page 33
Service Manual TDR8 P Gas form 9124023 rev. 01/2022
PT 1000 SENSOR
1. Remove the right side panel, the top
cover and the air suction plate according
prior procedures.
2. Remove the wing nut on the fan blade
and remove fan blade. (Left handed
threads).
3. Disconnect wiring of the motor.
4. Remove the screws that secure the motor
and remove the motor.
5. Reverse the procedure to install.
Note:
The blowers are equipped with a capa-
citor of 1.5uF. Check the direction of rotation
of the motor (clockwise, see arrows) and
change the wiring if necessary.
BLOWER MOTOR
1. Remove the right side panel according
prior procedure.
2. Disconnect the wiring of the sensor.
3. Remove the screw that secures the sensor
and remove the sensor.
4. Reverse the procedure to install.
Note: The wiring cable is an insulated cable
with an earthing screen.