ELECTRICAL TESTS AND SERVICE PROCEDURES
Page 46
Service Manual TDR8 P Gas form 9124023 rev. 01/2022
With the flue gas analyser you can measure the exhaust gas on the rotisserie for toxicity.
With the use of a Testo 330-1LL you get the following measurements:
Testo 330-1LL
V1.21
01297080
100035026
G 20
06.03.2014
11:42:13
Fuel:
Natural
gas
O2 ref.:
3.0%
CO2 max:
9.1%
5.2 %
Oxigen
9.0 %
CO2
1.33
Lambda
5
ppm
CO
0.01
GI
26.7 %
qR
73
efficiency
54
°C
dew
point
130°F
378 °C
Exhaust gas temp.
713°F
23
°C
Ambient temp.
74°F
The 2 most important values are the CO2 percentage and the exhaust gas temperature.
CO2% G 20/25 between 8.7 - 8.9%
CO2% G 30 between 10.4 - 10.6%
CO2% G 31 between 11.2 - 11.5%
CO max value 500 ppm
Exhaust gas between 370 - 420°C (698 - 788 °F)
FLUE GAS ANALYSER