Parts List

TROUBLESHOOTING MY-HITE

Error code

Explanation

Cause

Solution

H01

Motor has 

overheated

Overuse

1. 

Let motor rest for 10 minutes

2. 

Perform reset operation 

if problem persists

3. 

contact Friant customer service

ASR or 

RST (solid 

or flashing)

System is 

locked

Various Reasons 1. 

Remove plug from electrical outlet for 15 

seconds, then plug unit back in

2. 

Perform reset operation

if problem persists

3. 

contact Friant customer service to 

replace control panel

No display

Control 

Panel has 

lost power

Disruption in 

power supply to 

base

1. 

Remove plug from electrical outlet for 15 

seconds, then plug unit back in

2. 

Perform reset operation

if problem persists

3. 

contact Friant customer service to 

replace control panel

E01, 

E02, or

E03

Excessive 

weight 

distribution

Too much 

weight (limit 

exceeded)

or

 

Other problem

1. 

Check that weight on table does not 

exceed limit

2. 

Perform reset operation 

if problem persists

3. 

contact Friant customer service to 

replace control panel

E07,

E08, or

E09

Signal 

Interruption 

Signal is 

interrupted 

between leg 

and computer 

1. 

Perform reset operation

if problem persists

2. 

contact Friant customer service

CLEAR MAXIMUM & MINIMUM HEIGHT

1. 

Table can be at 

ANY HEIGHT

 but 

NOT

 the minimum or maximum.

2.  Hold “S” til display flashes. Release button.
3.  Press “S” slowly, multiple times - until “555” shows on display. 

Note: Display will show other codes, continue to press “S” until “555” shows.

4.  Display will then show table height and can now move to any height between 

24.5” and 50.1”. 

PART#

NAME

PIECES

A

Side Bracket

2

B

Column Leg

2

C

Pad

1

D

Crossbeam

2

E

Center Rails

2

F

Control Panel

1

G

Control Box

1

H

Telescopic Cover Plate

1

I

Connector Wires

 

J

Feet

2

K

Socket Button Head Bolt 
M6*20mm

8

L

Socket Button Head Bolt 
M6*12mm

16

M

Wire Manager

3

N

Truss Head Screw 
M5*20mm

26

Summary of Contents for FSQAHTB

Page 1: ...DJUSTABLE TABLE ModelNumber FSQAHTB Please Read Instructions Before Use ASSEMBLY INSTRUCTIONS FRIANT ASSOC 4901 E 12 STREET OAKLAND CA 94601 T 510 535 5113 FAX 510 535 5237 www Friant com systems my hite 081717 ...

Page 2: ...em 3 Check that the load on the table does not exceed limits 220lbs straight 330lbs corner 4 Table should be level and aligned at all times Thank you for choosing Friant We appreciate the trust and confidence you have placed in us and are committed to providing you the best possible product When placing table in final location be sure there is ample room for adjustment around ALL sides and at the ...

Page 3: ...ntify each component especially those that are similar The most common mistake is mixing up the order and placement of parts ToolsNeeded Follow assembly instructions closely Do not overload the tables 220 lbs maximum straight 330 lbs maximum corner The input voltage should be within 108 132V Use the glides to properly level the table before use When moving the table do not tilt the table on one le...

Page 4: ...it exceeded or Other problem 1 Check that weight on table does not exceed limit 2 Perform reset operation if problem persists 3 contact Friant customer service to replace control panel E07 E08 or E09 Signal Interruption Signal is interrupted between leg and computer 1 Perform reset operation if problem persists 2 contact Friant customer service CLEARMAXIMUM MINIMUMHEIGHT 1 Table can be at ANY HEIG...

Page 5: ... button 2 Press the arrow down V button again and hold til ASR shows on the display 3 Release the button and the ASR will flash on the display 4 Hold the arrow down button again Table will shift up and down slightly as it resets to 24 5 V 1 Press the arrow up button to get to desired maximum height Note the arrow up button must be the last button pressed to set the maximum height You cannot press ...

Page 6: ...g s repeating steps 3 4 Remove pad when done Make sure the length of the plug in cord is appropriate to both reach the outlet AND for the distance the table will travel up and down Range 24 5 at lowest to 50 highest Step 15 Install the G telescopic cover plates leaving exit space for the electrical power cords and secure to worksurface with M 8 truss head screws M5 20mm Step 16 Turn table right si...

Page 7: ...ils should be centered between crossbeams Center leg assemblies on the worksurface Make sure your overhang is even on both sides K SOCKET BUTTON HEAD BOLT M6 12mm Base is A 38 68 Maximum recommended top 78 wide Minimum recommended top 40 wide Step 14 Connect E control panel to F control box with H connector wires as shown Use L wire manager to secure H connector wires to underside of worksurface H...

Page 8: ...mm Step 13 Insert the F control box in between crossbeam Step 12 Secure the E control panel in the desired location with M 2 truss head screws M5 20mm Step 10 Ensure the leg assembly is still centered both side to side and front to back Secure the leg assembly to the worksurface with M 8 truss head screws M5 20mm M TRUSS HEAD SCREWS M5 20mm F CONTROL BOX E CONTROL PANEL ...

Reviews: