26
Figure 24
5.6
AKHP-TL Tapping Ball Valves d 250 - d 560
AKHP-TL Tapping Ball Valves allow
the drilling of unpressurised or
pressurised pipelines.
WARNING!
The fusion zone of the component
includes the dimensions d 250-
d 560. If necessary application
technological restrictions have to
be regarded. For example by borer
tool or balloon, normally applicable up to d 315 SDR 11. Details of these
components, given by manufacturer, have to be regarded.
5.6.1 Assembly
The preparation of the installation and the fusion process of the tapping ball
valve AKHP is made as saddle component analogue to the
FRIALEN
®
Pressure Tapping Tee
(see items 5.1.1 - 5.1.5).
INFORMATION:
For a leakage-free tapping of pressurised pipings, we recommend the
tapping unit of the company of Hütz + Baumgarten, Remscheid
(www.huetz-baumgarten.de). Please ask our Application Engineering
Department.
The telescopic FRIALEN-actuation key BS is particularly designed for the
technical and geometrical requirements of the KHP ball valve.
6.
Pipeline relining
6.1
Procedures and areas of application
Defective old pipelines made of cast iron, steel or other conventional materials
can be renovated by drawing in an HDPE pipe, as an alternative to laying new
pipes.
Standard pipes are used for the
relining process
and are joined using
suitable FRIALEN
®
Safety Fittings.
FL_2104_8_GB_II_08.p65
25.03.2008, 9:48 Uhr
26
Summary of Contents for FRIALEN
Page 31: ...31 ...