Elztrip EZ100
11
GB
Application area
Elztrip EZ100 has a single heating panel
and is designed for ceiling heights between
2.5 and 4 metres. EZ100 is used in shops,
schools, exhibition halls, workshops and
hospitals. Private homes and offices are also
common areas of use.
EZ100 is suitable both for total and
supplementary heating, as well as for
protection against cold draughts from large
glass surfaces. Protection class: IP44.
Operation
The panels have an operating temperature of
up to 320ºC and the heat is radiated to cold
surfaces. Heating with radiant heaters is very
energy effecient and a high comfort level is
obtained.
Mounting
Elztrip EZ100 is mounted on the ceiling, on
armature rails or suspended from the ceiling
by means of rods or chains. EZ100 is intended
for permanent installation and should always
be mounted horizontally.
In rooms frequently used, the heater should
be mounted 1.5 to 2 metres above head
height, see Fig. 3. The distance between the
panels should not be more than the height
between panel and floor, i.e ”a” should be less
than ”H” , see Fig.3. For minimum mounting
distance, see Fig.4.
Ceiling fixtures and screws are found inside
the connection box.
Mounting on the ceiling
1. Mount the ceiling fixtures on the ceiling.
2. Open the folded mounting hinges on the
top side of the heater and hang the heater
on the ceiling fixtures. See Fig. 1. Make sure
that the guide pegs are fitted into the holes, to
ensure that the heater is fixed in a horizontal
position. Fasten the screws.
Mounting on the wall (only horizontal)
Brackets for wall mounting (EZMVK) are
extra.
1. Mount the bracket on the wall.
2. Open the folded mounting hinges on the
top side of the heater and hang the heater
on the brackets. See Fig. 2. Make sure that
the guide pegs are fitted into the holes, to
ensure that the heater is fixed in a horizontal
position. Fasten the screws.
Connection
The terminal box cover has self-tapping
screws. The screw should only be unthreaded
1,5 turns, after which the cover can be
removed. NB While the screw is self-tapping,
the thread is vunerable to damage if the screw
is fully removed and replaced several times.
EZ100 is intended for 230V~ and permanent
installation. The heater(s) should only be
wired by a competent electrician, and in
accordance with existing national regulations.
The appliance should be preceded by
a double pole switch with at least 3 mm
breaking gap. There are two holes with cable
glands Ø 21mm on the top of the connection
box. Connection and serial connection of
EZ100 is done with a maximum cable size of
4x2.5 mm
2
+ earth.
Installation and operating instructions
General Instructions
Read these instructions carefully before
installation and use. Keep this manual for
future reference.
The product may only be used as set out in
the assembly and operating instructions. The
guarantee is only valid if the product is used
in the manner intended and in accordance
with the instructions.
Control
When using this product as a local space
heater according to Ecodesign Regulation
(EU) 2015/1188, it must be supplemented
with one of the following approved controls.
• TAP16R, electronic thermostat that
includes:
- Electronic room temperature control plus
week timer
- Room temperature control with open
window detection
• TAP16R and SKG30, black bulb sensor that
include:
- Electronic room temperature control plus
week timer