Fan Heater Panther 6-15 kW
3
Typ
E-nr
Effektsteg
[kW]
Luftflöde
[m³/h]
Ljudnivå
*
1
[dB(A)]
∆
t*
2
[°C]
Spänning
[V]
Ström
[A]
HxBxD
[mm]
Vikt
[kg]
SE06
87 112 50
0/3/6
900/1300
39/47
20/14
400V3N~
8,7
520x450x510
21
SE09
87 112 51
0/4,5/9
900/1300
39/47
30/21
400V3N~
13,0
520x450x510
22
SE12
87 112 52
0/6/12
900/1300
39/47
40/28
400V3N~
17,3
520x450x510
22
SE15
87 112 53
0/7,5/15
900/1300
39/47
50/35
400V3N~
21,7
520x450x510
22
SE135
87 112 36
0/5/10
0/7/13,5
900/1300
39/47
34/23
45/31
440V3~*
3
500V3~
13,4
15,6
520x450x510
23
*
1
) Conditions: Distance to the unit 3 metres. Directional factor: 2. Equivalent absorption area: 200 m
2
.
*
2
)
∆
t = temperature rise of passing air at maximum heat output at lowest/highest airflow.
*³) Can be connected to 440V3~ and 500V3~.