Tiger 20-30 kW

GB

General Instructions

Read these instructions carefully before 
installation and use. Keep this manual for 
future reference.

The product may only be used as set out in 
the assembly and operating instructions. The 
guarantee is only valid if the product is used 
in the manner intended and in accordance 
with the instructions.

Application area

Tiger is a range of robust and compact fan 
heaters for professionals with high demands. 
The Tiger fan heater is portable. Tiger 20 
and 30 kW are ideal for heating and drying 
larger premises such as industrial premises 
and workshops, where higher outputs are 
required. 
Protection class: IP44.

Electrical installation

The Tiger fan heater is equipped with a 1.8 
metre long connection cable. P203 has  a CEE 
plug fitted on the connection cable. P303 and 
P305 are supplied with a cable without a plug. 
P305 can be connected to both 440V3~ and 
500V3~.

Start-up 

When the unit is used for the first time or 
after a long period of disuse, smoke or odour 
may result from dust or dirt that has collected 
on the element. This is completely normal 
and disappears after a short time.

Operation

Position of the output selector, see Technical 
data.

Working range of the thermostat 5 - 35 °C.

The mode selector has two different fan 
speed positions.

The unit is equipped with mechanic 
thermostat room temperature control and can 
be used as a local space heater according to 
Ecodesign Regulation (EU) 2015/1188.
If the unit does not work the first time it 
is used, the temperature cut-out may have 
tripped during transport. See “Overheating”.

Overheating

If the unit overheats the in-built temperature 
cut-out will trip. Reset the temperature cut-
out once the unit has cooled and the fault has 
been rectified. (Fig. 1).

NOTE! All work inside the unit’s connection 
area must be carried out by a qualified 
technician and while the unit is not voltage 
fed.

Maintenance

Normally the heater fans do not require any 
maintenance. Dirt and dust can however 
cause overheating and represent a fire risk. 
Consequently, the unit should be cleaned 
periodically.

Residual current circuit breaker 

When the installation is protected by means 
of a residual current circuit breaker, which 
trips when the appliance is connected, 
this may be due to moisture in the heating 
element. When an appliance containing a 
heater element has not been used for a long 
period or stored in a damp environment, 
moisture can enter the element.
This should not be seen as a fault, but is 
simply rectified by connecting the appliance 
to the mains supply via a socket without a 
safety cut-out, so that the moisture can be 
eliminated from the element. The drying 
time can vary from a few hours to a few days. 
As a preventive measure, the unit should 
occasionally be run for a short time when it is 
not being used for extended periods of time.

Assembly and operating instructions

Summary of Contents for Tiger P203

Page 1: ...er sporadisk bruk FR Ce produit ne peut être utilisé que dans des locaux bien isolés ou de manière occasionnelle DE Dieses Produkt ist nur für gut isolierte Räume oder für den gelegentlichen Gebrauch geeignet FI Tämä tuote soveltuu ainoastaan hyvin eristettyihin tiloihin tai satunnaiseen käyttöön NL Dit product is uitsluitend geschikt voor goed geïsoleerde plaatsen of voor incidenteel gebruik RU П...

Page 2: ...A C B 2 Tiger 20 30 kW Fig 1 A mm B mm C mm P203 P303 P305 630 590 600 ...

Page 3: ... 230V 3 400V 3 C Low speed High speed C M 2 1 L L L1 2 3 Tiger 30kW P303 230V3 400V3 Tiger 30kW P305 440 500V3 400V 3 230V 3 1 2 400V 3 400V 3 C 400V 3 230V 3 3 3 3 2 3 1 3 0 3 L L 1 2 3 440V 3 500V 3 440V 500V L Low speed High speed 3 Tiger 20 30 kW Tiger 30 kW Tiger 20 kW ...

Page 4: ...3 meter Riktningsfaktor 2 Ekvivalent absorptionsarea 200 m 2 t temperaturhöjning på genomgående luft vid maximal värmeeffekt och lägst respektive högst luftflöde 3 Kan anslutas till både 440V3 och 500V3 Kapslingsklass IP44 CE märkt 1 Betingelser Avstand til aggregat 3 meter Retningsfaktor 2 Ekvivalent absorpsjonsareal 200 m 2 t temperaturøkning på gjennomstrømmende luft ved maksimal varmeeffekt og...

Page 5: ...tat room temperature control and can be used as a local space heater according to Ecodesign Regulation EU 2015 1188 If the unit does not work the first time it is used the temperature cut out may have tripped during transport See Overheating Overheating If the unit overheats the in built temperature cut out will trip Reset the temperature cut out once the unit has cooled and the fault has been rec...

Page 6: ...d with clothes or similar material as overheating can represent a fire risk The unit must not be placed directly under a permanent wall socket This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a s...

Page 7: ...co AB Tel 46 31 336 86 00 Industrivägen 41 SE 433 61 Sävedalen mailbox frico se Sweden www frico net For latest updated information and information about your local contact www frico net Art nr 201226 2018 01 25 HH CH ...

Reviews: