Page 1: ...nformation can be found on the name plate located on the side of the unit near the control panel Please complete and mail the owner registration card furnished with this product or register on line at www friedrich com USA only For your future convenience record the model information here MODEL NUMBER SERIAL NUMBER PURCHASE DATE ...

Page 2: ......

Page 3: ...conditioner The Friedrich unit is designed to give maximum comfort and quietness Table of Contents Introduction 2 Safety Precautions 3 How to operate your Friedrich 5 Features and Installation 7 Installation Instructions 8 Troubleshooting Tips 11 Warranty 12 ...

Page 4: ... AMP VOLT 15 125 PLUG FACE NEMANO 5 15P Figure 1 For the Best Cooling Performance and Energy Efficiency Keep the filter clean Make sure that your air conditioner is always in top performing condition by cleaning the filter regularly Instructionsfor removing and cleaning the filter can be found on page 6 Provide good airflow Make sure that the airflow to and from the unit is dear Your air condition...

Page 5: ...ibility of injury or damage to _ properties only Meanings of symbols used in this manual are as shown below I I everoot 1 0 wa sOoThis Otherwise it will cause electric shock or fire due to heat generation it will cause electric shock or fire due to heat generation Itwill cause electric shock or fire If the power cord is damaged it must bereplaced by the manufactureror a Friedrich certifiedservice ...

Page 6: ...anger This could injure the pets or plants Do not use this air conditioner to preserve precision devices food pets plants and art objects It may cause deterioration of quality etc It may cause an electric shock It may cause a fire or Use caution when handling the deformation of the cabinet case Grip it firmly and do not allow it to slip while holding it Useheavyglovesto handle ___e _r_ the caseif ...

Page 7: ...or 30 minutes the temperaturewill automaticallyrise 2 F and afteranother 30 minutes it will automaticallyrise 2 F again The temperaturewill then stay the sameuntil the timer goes OFF To cancel the timer pressthe TIMERpad untilthe displaytime disappears _ POWER To turn the unit ON pushthe button To turn the unit OFF push the buttonagain This buttontakes priorityoverany other buttons Whenyou first t...

Page 8: ...l the water before replacing the filter Do not force open or open too far Fig 1 CLEANING THE AIR CONDITIONER The front grille and Inlet grille may be wiped with a cloth dampened in a mild detergent and lukewarm water solution Fig 2 The cabinet may be washed with mild soap or detergent and lukewarm water Fig 2 To ensure continued peak efficiency the condenser coils outside of unit should be checked...

Page 9: ...key components will help you properly install the unit Features t 9 6 t0 8 1 CABINET 2 HORIZONTAL AIR DEFLECTOR 3 COOL AIR DISCHARGE 4 FRONT GRILLE 5 INLET GRILLE 5 6 AIR FILTER 7 CONTROL BOARD 8 AIR INTAKE 9 UPPER GUIDE 10 REMOTE CONTROLLER ...

Page 10: ...tely 3 4 higher than the storm window frame STORM WINDOW FRAME or wood strip OUTDOORS to help condensation to drain properly to the outside 3 Install a second wood strip approximately 6 long by 11 2 wide and same thickness as first strip in the center of the outer sill flush against the back off the inner sill This will raise the L bracket as shown Fig 5 2 4 If the distance between STORM WINDOW FR...

Page 11: ...e bracket helps to hold unit securely in place Be sure to place bracket edge flush against back of inner sill See Fig 9 3 INSTALLTHEAIR CONDITIONERIN THEWINDOW a Carefully lift the air conditioner and slide it into the open window Make sure the bottom guide of the air conditioner drops into the notches of the L bracket See Fig 9 During the following step hold unit firmly until window sash is lower...

Page 12: ...A for attaching power cord to electrical outlet L BRACKET TYPE A_ Fig 12 L BRACKET EAL ABOUTII4 SASH SEAL TYPE B REMOVAL FROM WINDOW Turn the air conditioner off disconnect the power cord remove the L bracket and the screws installed through the top and bottom of the guide panels and save for reinstallation later Close the guide panels Keeping a firm grip on the air conditioner raise the sash and ...

Page 13: ...the air conditioner plug is pushed completely into the outlet Air conditioner does not start Air conditioner does not cool as it should Air conditioner freezing up Check the house fuse circuit breaker box and replace the fuse or reset the breaker If power failure occurs turn the mode control to Off When power is restored wait 3 minutes to restart the air conditioner to prevent tripping of the comp...

Page 14: ...fuses 2 Products on which the model and serial numbers have been removed 3 Products which have defects or damage which results from improper installation wiring electrical current characteristics or maintenance or caused by accident misuse or abuse fire flood alterations and or misapplication of the product and or units installed in a corrosive atmosphere default or delay in performance caused by ...

Page 15: ...FRIEDRICH AIR CONDITIONING CO Visit our web site at www friedrich com Post Office Box 1540 4200 N Pan Am Expressway San Antonio Texas 78295 1540 210 3574400 FAX 210 3574480 P NO 3828A20126F ...