Art. 138 - Particular standards

 

3. It is forbidden to throw scaffolding parts from heights.

 

Art. 140 - Tower bridge castors.

 

1) 

Bridges on castors must have an ample base to resist, with a wide safety margin, loads and oscillations they can be 

subjected to during movements or gusts of wind and in such a way they cannot overturn.

(Strictly comply with the 

assembly instructions.)

 

2)  The sliding surface of the castors must be level; the load of the bridge on the ground must be adequately divided with 

boards or other equivalent means.

 

3)  The castors of the bridge in place must be firmly fastened with wedges on both sides or equivalent systems.

 

4)  Bridges on castors must be anchored to the building at least every two platforms; exception is made for tower bridge 

castors in compliance with Annex XXIII 

(compliance with European 

legislation).

 

5)  The verticality of the bridges on castors must be controlled with a level or pendulum line.

 

6)  The bridges, excluding those used in works for contact electrical lines, must not be moved when workers or loads are on 

them.

 

 

 

 

DECLARATION OF CONFORMITY 

It is hereby certified that the scaffold  
on a POKER base was constructed in 
compliance with Legislative Decree 81  
on 9 April 2008. 

 

It is also declared that the same scaffold, 
in the POKER HD configurations complies 
with the European standard UNI-EN 
1004. 

 

In this regard, it is declared that the 
POKER-HD scaffold has passed the tests 
outlined in Annex XXIII of LD 81-08. 
The tests were carried out by the Material 
Testing Laboratory in Milan Polytechnic, 
as per the test certificate 
no. 2002/742 issued in Milan  
on 20/03/2002. 

FRIGERIO CARPENTERIE S.p.A. 

 
 
 

 

User's responsibility: 

The manufacturer cannot be held responsible for any damage to people or property caused by improper use of the mobile 

scaffold or by total or partial non-compliance with the standards outlined in this manual, or lack of periodic controls or 

maintenance against possible damage caused by use or atmospheric agents. 

You are advised, in this respect, to carry out careful controls of the parts of the mobile 

scaffold before each use and comply with the legal provisions on occupational safety. 

All rights reserved. It is forbidden to partially or fully reproduce the content of this manual. 

Summary of Contents for POKER

Page 1: ...mobile scaffolding POKER POKER HD Compulsory warnings for assembly use movements and dismantling of the mobile scaffold This manual must always accompany the mobile scaffold if it must be shown to com...

Page 2: ...2 2 2 2 2 2 P TIR L Diagonal tie rod 1 1 4 4 8 8 12 12 16 POK 1 2 TIR Half diagonal tie rod 0 8 0 4 0 4 0 4 0 POK BN SR Complete base No 2 pieces without castors 4 8 1 1 1 1 1 1 1 POK RUOTA Castors 1...

Page 3: ...mbing on the mobile scaffold during assembly use and after each movement always check the brackets are correctly and firmly positioned End Sill POK DAVTER Vertical Upright POK SPALLA For POKER 01 only...

Page 4: ...ngs on the vertical uprights or if necessary the climbing ladders available on request Having passed through the work platform always ensure the trapdoor is closed Always work on a work platform prote...

Page 5: ...e work platform so it is positioned at a distance of approx 0 58 m over the work platform manually tightening the clamps on the vertical tubes N B The anti uncoupling safety devices must be assembled...

Page 6: ...POK DAVANZ Sill 3 0 0 2 2 4 4 6 6 POK DAVTER End Sill 2 9 2 2 2 2 2 2 2 P TIR L Diagonal tie rod 1 1 4 4 8 8 12 12 16 POK 1 2 TIR Half diagonal tie rod 0 8 0 4 0 4 0 4 0 POK BN SR Complete base in two...

Page 7: ...m and 1 10 m over the work platform and the other brace acts as an intermediate handrail resting on the 2nd rung over the work platform so it is positioned at a distance of approx 0 58 m over the work...

Page 8: ...on which the tower is moved must be capable of supporting the weight After each movement braking and stabilising the mobile scaffold is compulsory Also check it is perfectly vertical It is forbidden t...

Page 9: ...llowing the instructions provided to guarantee state of the art execution and if this is in the vertical position Before each use you must ensure all the safety measures were taken to prevent accident...

Page 10: ...main contents of specific training planned in the State Regions Agreement on the 21 December 2011 Reference Standards L D 81 9 April 2008 Consolidated Safety Act Uni EN 1004 2005 Mobile access and wo...

Page 11: ...installation of protective equipment against falling The aforementioned equipment may present such a configuration and resistance to avoid or stop falling from workplaces at heights and prevent as muc...

Page 12: ...when workers or loads are on them DECLARATION OF CONFORMITY It is hereby certified that the scaffold on a POKER base was constructed in compliance with Legislative Decree 81 on 9 April 2008 It is also...

Page 13: ...ary protecting from dirt by applying a strip of transparent adhesive tape Test date Part examined Test OK Test NOT OK Description of fault Name of test person Signature Repair date Repair type Name of...

Page 14: ...the event of test OK or test NOT OK if necessary protecting from dirt by applying a strip of transparent adhesive tape Test date Part examined Test OK Test NOT OK Description of fault Name of test per...

Page 15: ...the event of test OK or test NOT OK if necessary protecting from dirt by applying a strip of transparent adhesive tape Test date Part examined Test OK Test NOT OK Description of fault Name of test pe...

Page 16: ...www frigeriospa com Frigerio Carpenterie S p A V Fermi 6 24050 Orio Al Serio BG Fax 035 525147 E mail info frigeriospa com...

Reviews: