8.4.8 HOLIDAY AWAY SETTING
The HOLIDAY AWAY SETTING is used to set the outlet
water temperature to prevent freezing when away for
holiday.
Go to MENU> FOR SERVICEMAN> 8.HOLIDAY AWAY
SETTING. Press OK. The following page will be
displayed:
Press ▼ ▲ to scroll and set the phone number. The
maximum length of the phone number is 13 digits, if the
length of phone number is short than 12, please input ■,
as shown below:
8.4.9 SERVICE CALL SETTING
The installers can set the phone number of the local
dealer in SERVICE CALL SETTING. If the unit doesn’t
work properly, call this number for help.
Go to MENU> FOR SERVICEMAN>SERVICE CALL.
Press OK. The following page will be displayed:
ADJUST
OK
CONFIRM
20°C
20°C
8 HOLIDAY AWAY SETTING
8.1 T1S_H.A._H
8.2 T5S_H.A._DHW
ADJUST
9 SERVICE CALL SETTING
PHONE NO. ******************
MOBILE NO. ******************
NON
6 ROOM THERMOSTAT
6.1 ROOM THERMOSTAT
ADJUST
If you set DOUBLE ZONE and ROOM TEMP. to YES,
meanwhile set WATER FLOW TEMP. to YES or NON,the
following page will be displayed.
Homepage (zone 1)
2
Addition page (zone 2)
(Double zone is effective)
◄
◄
In this case, the setting value of zone 1 is T1S,the setting
value of zone 2 is T1S2 (The corresponding TIS2 is
calculated according to the climate related curves.)
8.4.6 ROOM THERMOSTAT
About ROOM THERMOSTAT
The ROOM THERMOSTAT is used to set whether the
room thermostat is available.
How to set the ROOM THERMOSTAT
Go to MENU> FOR SERVICEMAN> 6.ROOM
THERMOSTAT. Press OK. The following page will be
displayed:
In this case, the setting value of zone 1 is T1S,the setting
value of zone 2 is T1S2.
8.4.7
OTHER
HEATING SOURCE
The OTHER HEATING SOURCE is used to set the
parameters of the backup heater, additional heating
sources .
Go to MENU> FOR SERVICEMAN> 7.OTHER HEATING
SOURCE, Press OK. The following page will be dispayed:
ROOM THERMOSTAT = NON, no room
thermostat.
ROOM THERMOSTAT = MODE SET, the wiring of
room thermostat should follow method A.
ROOM THERMOSTAT=ONE ZONE, the wiring of
room thermostat should follow method B.
ROOM THERMOSTAT=DOUBLE ZONE, the wiring
of room thermostat should follow method C (refer
to
7.6 "Connecting for other components/For
room thermostat"
)
NOTE
30MIN
-5°C
5°C
30MIN
5°C
7 OTHER HEATING SOURCE
7.1 dT1_IBH_ON
7.2 t_IBH_DELAY
7.3 T4_IBH_ON
7.4 dT1_AHS_ON
7.5 t_AHS_DELAY
ADJUST
1/2
-5
°C
7 OTHER HEATING SOURCE
7.6 T4_AHS_ON
7.7 IBH LOCATE PIPE LOOP
7.8 P_IBH1
7.9 P_IBH2
7.10 P_TBH
ADJUST
2/2
0.0kW
0.0kW
2.0kW
31