background image

10

ELECTRICAL INSTALLATION

ELECTRIC Dryer

 The following are specific requirements for

proper and safe electrical installation of your dryer. Failure
to follow these instructions can create electrical shock and/
or a fire hazard.

 

This appliance MUST be properly grounded.

Electrical shock can result if the dryer is not properly grounded.
Follow the instructions in this manual for proper grounding.

 

Do not use an extension cord with this dryer.

Some extension cords are not designed to withstand the amounts
of electrical current this dryer utilizes and can melt, creating
electrical shock and/or fire hazard. Locate the dryer within reach
of the receptacle for the length power cord to be purchased,
allowing some slack in the cord. Refer to the pre-installation
requirements in this manual for the proper power cord to be
purchased.

 

 

A U.L. approved strain relief must be installed

onto power cord. 

If the strain relief is not attached, the cord

can be pulled out of the dryer and can be cut by any movement
of the cord, resulting in electrical shock.

 

 Do not use an aluminum wired receptacle

with a copper wired power cord and plug (or vice versa).

A chemical reaction occurs between copper and aluminum and
can cause electrical shorts. 

The proper wiring and receptacle

is a copper wired power cord with a copper wired
receptacle.

NOTE:

 Dryers operating on 208 volt power supply will have longer

drying times than operating on 240 volt power supply.

GROUNDING REQUIREMENTS

USA ELECTRIC Dryer

 Improper connection of the equipment grounding

conductor can result in a risk of electrical shock. Check with a
licensed electrician if you are in doubt as to whether the appliance
is properly grounded.

For a grounded, cord-connected dryer:

1. The dryer 

MUST

 be grounded. In the event of a malfunction

or breakdown, grounding will reduce the risk of electrical shock
by a path of least resistance for electrical current.

2. If your dryer is equipped with a power supply cord having an

equipment-grounding conductor and a grounding plug, the
plug 

MUST

 be plugged into an appropriate, copper wired

receptacle that is properly installed and grounded in
accordance with all local codes and ordinances. If in doubt,
call a licensed electrician.

  Do not modify plug provided

with the appliance.

For a permanently connected dryer:

1. The dryer 

MUST

 be connected to a grounded metal, permanent

wiring system; or an equipment grounding conductor must be
run with the circuit conductors and connected to the
equipment-grounding terminal or lead on the appliance.

Canadian ELECTRIC Dryer

DANGER

 Improper connection of the equipment grounding

conductor can result in a risk of electrical shock. Check with a
licensed electrician if you are in doubt as to whether the appliance
is properly grounded.

For a grounded, cord-connected dryer:

1. The dryer must be grounded. In the event of a malfunction or

breakdown, grounding will reduce the risk of electrical shock
by a path of least resistance for electrical current.

2. Since your dryer is equipped with a power supply cord having

an equipment-grounding conductor and a grounding plug,
the plug must be plugged into an appropriate outlet that is
properly installed and grounded in accordance with all local
codes and ordinances. If in doubt, call a licensed electrician.

Do not modify plug provided with the appliance.

ALL GAS Dryers

1. The dryer is equipped with a three-prong (grounding) plug
    for your protection against shock hazard and should be
    plugged directly into a properly grounded three-prong
    receptacle. Do not cut or remove the grounding prong
    from the plug.

Summary of Contents for 134940500A

Page 1: ...1 www frigidaire com P N 134940500A 0804 Installation Instructions Gas Electric Dryer Instructions d installation Sécheuse à gaz ou électrique ...

Page 2: ...e followed to minimize the risk of fire or explosion or to prevent property damage personal injury or loss of life SAVE THESE INSTRUCTIONS Do not store or use gasoline or other flammable vapors and liquid in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Clear the roo...

Page 3: ...located so the power supply cord is accessible when the dryer is in the installed position Canada NEMA 14 30R receptacle NOTE Do not under any circumstances remove grounding prong from plug GROUNDING PRONG EXHAUST SYSTEM REQUIREMENTS Use only 4 inch 10 2 cm diameter minimum rigid or flexible metal duct and approved vent hood which has a swing out damper s that open when the dryer is in operation W...

Page 4: ...e floor Failure to do so can result in death explosion fire or burns 1 Connect an inclined or digital manometer between the dryer and the point the exhaust connects to the dryer 2 Set the dryer timer and temperature to air fluff cool down and start the dryer 3 Read the measurement on the manometer 4 The system back pressure MUST NOT be higher than 0 75 inches of water column If the system back pre...

Page 5: ...s are required to be unobstructed when a door is installed A louvered door with equivalent air openings for the full length of the door is acceptable MINIMUM INSTALLATION CLEARANCES Inches cm SIDES REAR TOP FRONT Alcove 0 0 cm 0 0 cm Closet 0 0 cm 0 0 cm 1 2 54 cm Closet door ventilation required 2 louvered openings each 60 square inches 387 square centimeters 3 inches 7 6 cm from bottom and top o...

Page 6: ...t 13 5 27 25 to front of cabinet 27 75 to clear knobs 28 5 to clear door handle 5 875 To base exhaust 5 0 4 375 To side exhausts To rear base exhausts 2 25 2 375 Gas supply pipe on rear of unit Electrical supply on rear of unit 123 19cm 72 39cm 12 7cm 11 12cm 14 93cm 69 22cm 70 49cm 72 39cm 5 72cm 6 03cm 68 58cm 34 29cm 36 91 44cm Dryer Installation Dimensions Free Standing Under Counter Stacked D...

Page 7: ... latest editions for HOME USE only REVERSING DOOR SWING Solid Door Reversing Instructions 1 Open door and remove four 4 plugs in the door opening opposite the hinges Retain all parts for uses later un less otherwise noted Note Use care in removing plugs in not scratching paint on the front panel 2 Begin removing the four 4 screws that attach the hinge to the front panel For best results start by o...

Page 8: ...o hinge front panel or door After the remaining screws are loosened continue to remove all Figure 3 3 Place door on a towel or pad handle side down to prevent any possible scratches to door Remove all remaining four 4 screws between hinge and door Figure 3 4 Remove four 4 screws from side of door opposite of where hinge was mounted Figure 4 5 Remove two 2 door handle screws and two 2 hole plugs fr...

Page 9: ...4 Install four 4 screws into holes that had secured the hinge 15 Remove striker and discard 16 Remove square plug and reinstall in hole striker was just removed 17 Install striker included in literature bag into hole square plug was previously installed Figure 12 18 Reinstall door handle by placing the handle mounting bosses through holes in lens and transition ring and installing screws through i...

Page 10: ...d For a grounded cord connected dryer 1 The dryer MUST be grounded In the event of a malfunction or breakdown grounding will reduce the risk of electrical shock by a path of least resistance for electrical current 2 If your dryer is equipped with a power supply cord having an equipment grounding conductor and a grounding plug the plug MUST be plugged into an appropriate copper wired receptacle tha...

Page 11: ... tighten the nut only at this time 3 Remove the ground wire from the green ground screw located above the terminal block RED BLACK WHITE GREEN 30 AMP NEMA 14 30 TYPE SRDT OR ST TYPICAL 4 CONDUCTOR TYPICAL 4 CONDUCTOR Printed in U S A 1 Remove the screws securing the terminal block access cover and the strain relief mounting bracket located on the back of the dryer upper corner 2 Install a U L appr...

Page 12: ... is turned on the safety switch will shut the burner off If this happens turn the timer to OFF and wait 5 minutes before making another attempt to light 6 If your dryer does not operate please review the Avoid Service Checklist located in your Use and Care Guide before calling for service 7 Place these instructions in a location near the dryer for future reference NOTE A wiring diagram is located ...

Page 13: ...atement en utilisant le téléphone d un voisin Suivre les directives du fournisseur de gaz S il est impossible de joindre le fournisseur de gaz appeler le service de protection des incendies L installation et les réparations doivent être effectuées par un service de réparation un technicien qualifié ou le fournisseur de gaz Table des matières Avant l installation 13 Installation électrique 14 Évacu...

Page 14: ...uit ALIMENTATIONÉLECTRIQUE 3 fils 240 volts unephase 60 Hz courantalternatif Canada 240 volts unephase 60 Hz courant alternatif CORDOND ALIMENTATIONÉLECTRIQUE 3FILS Lasécheuse DOIT être reliée à un cordon d alimentation électrique à 3 conducteursNEMA10 30detypeSRDTd unecapacitéminimale de 240 volts courant alternatif 30 A avec fiche en L à 3 broches pleines ou repliées conçue pour le branchement d...

Page 15: ...GRILLE DE SORTIE à volet TYPE DE GRILLE DE SORTIE à volet LONGUEUR MAXIMUM d une conduite en métal rigide de 10 16 cm 4 po de diam Recommandé Recommandé Nombre de coudes à 90 Nombre de coudes à 90 0 18 28 m 60 po 14 63 m 48 po 1 15 84 m 52 po 12 19 m 40 po 2 13 41 m 44 po 9 75 m 32 po 3 9 75 m 32 po 7 31 m 24 po 4 8 53 m 28 po 4 87 m 16 po 10 2 10 2 10 2 10 2 10 2 cm cm cm cm cm 4 po 4 po 4 po 4 p...

Page 16: ...décrite ci dessus est acceptable DÉGAGEMENTS MINIMAUX POUR L INSTALLATION en po cm D AVANT CÔTÉS ARRIÈRE DESSUS Alcôve ou sous un comptoir 0 0 0 0 0 0 0 0 Armoire 1 2 54 0 0 0 0 0 0 Aération nécessaire dans la porte de l armoire 2 ouvertures à persiennes de 60 pouces carrés 387 cm carrés chacun à 3 pouces 7 6 cm du bas et du haut de la porte L AÉRATION DE CETTE SÉCHEUSE SE FAIT VERS L EXTERIEUR 5 ...

Page 17: ...tion Dimensions 11 12cm 72 00 182 88cm 41 00 104 14cm 34 29cm 68 58cm 38 25 97 16cm 2 375 6 03cm Dimensions Empilées D Installation De Secheuse Dimensions D Installation De Secheuse Indépendant Et Sous Le Compteur À l espace libre ouvrez la porte Alimentation électrique sur l arrière de l unité Pipe d offre de gaz sur l arrière de l unité Ligne taille centrale pour arrière droit parti passage Aux ...

Page 18: ...e panneau du dessus peut être démonté pour l installation 2 Remettre la sécheuse à la verticale OUI NON PORTE RÉVERSIBLE Instructions pour changer l ouverture de la Porte sans Fenêtre 1 Ouvrez la Porte et enlevez les 4 bouchons d en face où on trouve la charnière Conservez toutes les pièces pour les utiliser postérieurement à moins qu on ne spécifie le contraire Note Ayez des soins en enlevant les...

Page 19: ...nière le Panneau Frontal ou à la Porte Après avoir détendu les vis restantes enlevez les complètement Figure 3 3 Placez la Porte avec le côté de la charnière vers le bas sur une serviette ou un matelas étroit pour éviter qu il soit doublé Enlevez les quatre 4 vis restantes entre la charnière et la porte Figure 3 4 Enlevez quatre 4 vis du côté de la Porte où était installée la charnière Figure 4 5 ...

Page 20: ... charnière 15 Enlevez le contre de la charnière et jetez le aux ordures 16 Enlevez le bouchon carré et installez le dans le trou où vous avez enlève le contre 17 Installez le contre même qui est fourni dans la bourse de la Littérature dans le trou tombé juste où vous avez enlève le bouchon Figure 12 18 Réinstallez de la poignée de la Porte en faisant passer les protubérances d assemblage de cette ...

Page 21: ...us les codes et ordonnances locaux Encasdedoute contacterunélectricienagréé Nemodifiez pas la prise équipée d appareil TOUTESlessécheusesàGAZ Pourvotreprotectioncontreleschocsélectriques lasécheuseest équipée d une fiche à trois bornes mise à la terre et doit être branchée directement dans une prise à 3 bornes correctement mise à la terre Ne pas couper ni enlever la fiche de mise à la terre de cet...

Page 22: ...MONTAGE DU DÉTENDEUR PANNEAU DE BRANCHEMENT FIL DE TERRE NEUTRE VIS DE MISE À LA TERRE VERTE BRANCHEMENTÉLECTRIQUED UNE INSTALLATIONÀ3 FILS Sécheuses ÉLECTRIQUES non Canadiennes 1 Retirer les vis qui retiennent le couvercle du panneau de branchement ainsi que le support de montage du détendeur situés dans le coin supérieur à l arrière de la sécheuse 2 Poser un détendeur approuvé par U L dans le tr...

Page 23: ...démarrage l interrupteur de sûreté éteint automatiquement le brûleur Si cela se produit remettre la minuterie à OFF et attendre 5 minutes avant de tenter une nouvelle fois d allumer le brûleur 7 Si la sécheuse ne fonctionne pas passer en revue la section de dépannageinclusdansleGuidedel utilisateuravantd appeler un centre de service 8 Placer cette notice près de la sécheuse pour référence future 9...

Page 24: ...__________ ______________________________________________________________ ______________________________________________________________ ______________________________________________________________ ______________________________________________________________ ______________________________________________________________ ______________________________________________________________ ___________...

Reviews: