background image

Important Safety Instructions

READ THIS SECTION BEFORE ATTEMPTING TO OPERATE AIR CONDITIONER.

Unit must be upright for one hour prior to operating.

Plug in &
press RESET

The power supply cord contains a current device that senses damage to the power cord. To test 
your power supply cord do the following:

Plug in the Air Conditioner.
The power supply cord will have TWO buttons on the plug head. Press the TEST button. You will
notice a click as the RESET button pops out.

Press the RESET button. Again you will notice a click as the button engages.
The power supply cord is now supplying electricity to the unit. (On some products this is also indi-
cated by a light on the plug head).

WARNING

For Your Safety

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any
other appliance. Read product labels for flammability and other warnings. 

WARNING

Prevent Accidents

To reduce the risk of fire, electrical shock, or injury to persons when using your air conditioner,
follow basic precautions, including the following: 

Be sure the electrical service is adequate for the model you have chosen. This information
can be found on the serial plate, which is located on the side of the cabinet and behind the
grille.

If the air conditioner is to be installed in a window, you will probably want to clean both
sides of the glass first. If the window is a triple-track type with a screen panel included,
remove the screen completely before installation. 

Be sure the air conditioner has been securely and correctly installed according to the
separate installation instructions provided with this manual. Save this manual and the 
installation instructions for possible future use in removing or reinstalling this unit. 

When handling the air conditioner, be careful to avoid cuts from sharp metal fins on front
and rear coils.

The complete electrical rating of your new room air conditioner is stated on the serial plate.
Refer to the rating when checking the electrical requirements. 

Be sure the air conditioner is properly grounded. To minimize shock and fire hazards,
proper grounding is important. The power cord is equipped with a three-prong grounding
plug for protection against shock hazards.  
Your air conditioner must be used in a properly grounded wall receptacle. If the wall
receptacle you intend to use is not adequately grounded or protected by a time delay fuse
or circuit breaker, have a qualified electrician install the proper receptacle.  

Do not run air conditioner without outside protective cover in place. This could result in
mechanical damage within the air conditioner.  

Do not use an extension cord or an adapter plug.

WARNING

Electrical Information

WARNING

Avoid fire hazard or electric shock. Do not
use an extension cord or an adaptor plug. Do
not remove any prong from the power cord.

NOTE:

The power supply cord with
this air conditioner contains a current
detection device designed to reduce the risk
of fire.
Please refer to the section ‘Operation of
Current Device’ for details.
In the event that the power supply cord is
damaged, it cannot be repaired. It must be
replaced with a cord from the product
manufacturer.

115V

15A

230V

15A

230V

20A

NOTE:

Do not use this device to turn the unit on or off.

Always make sure the RESET button is pushed in for correct operation.
The power supply cord must be replaced if it fails to reset when either the TEST button is pushed,
or it cannot be reset. A new one can be obtained from the product manufacturer.

If power supply cord is damaged, it CANNOT be repaired. It MUST be replaced by one obtained
from the product manufacturer.

2

2009 Electrolux Home Products, Inc.

All rights reserved.

NOTE:

This USE & CARE MANUAL provides specific operating instructions for your model. Use the room air conditioner only as 
instructed in this USE & CARE MANUAL. These instructions are not meant to cover every possible condition and situation that 
may occur. Common sense and caution must be practiced when installing, operating, and maintaining any appliance. 

230V

30A

Do not, under any
circumstances, cut, 
remove or bypass the 
grounding prong.

Grounding Prong

Summary of Contents for 2020218A0678

Page 1: ...l about the Use Care Care and Cleaning 10 Energy Saving Ideas 10 2020218A0678 June 2009 Product Registration 3 Packaging 3 Normal Sounds 3 Air Conditioner Features 4 Important Safety Instructions 2 Operating Instructions 4 9 of your Room Air Conditioner Before You Call 11 Major Appliance Warranty 12 ...

Page 2: ...g when checking the electrical requirements Be sure the air conditioner is properly grounded To minimize shock and fire hazards proper grounding is important The power cord is equipped with a three prong grounding plug for protection against shock hazards Your air conditioner must be used in a properly grounded wall receptacle If the wall receptacle you intend to use is not adequately grounded or ...

Page 3: ...rect installation Vibration Pinging or Swishing Droplets of water hitting condenser during normal operation may cause pinging or swishing sounds Sound of Rushing Air At the front of the unit you may hear the sound of rushing air being moved by the fan Gurgle Hiss Gurgling or hissing noise may be heard due to refrigerant passing through evaporator during normal operation Product Registration 3 Prod...

Page 4: ...represent the Touch Pad the same instructions can be used for the Remote Control TO TURN UNIT ON YOU WILL SEE PRESS ON OFF BUTTON DO THIS Air Conditioner Features Operating Instructions ADJUSTS TEMPERATURE OR TIME DISPLAYS TEMPERATURE TIME SETS FAN SPEED SETS MODE TURNS UNIT ON OR OFF ACTIVATES TIMER CHECK FILTER RESET BUTTON SLEEP MODE REMOTE TEMP SENSING INDICATOR some models CLEAN AIR FEATURE s...

Page 5: ...rns to the original set temperature Press either the fan slower or fan faster button to adjust the fan speed manually 2009 Electrolux Home Products Inc All rights reserved YOU WILL SEE PRESS TO RAISE PRESS TO LOWER DO THIS Note Tap or hold either up or down button until the desired temperature is seen on the display This tempe rature will be automatically maintained anywhere between 60 F 16 C and ...

Page 6: ...p mode program can be cancelled at any time during operation by again pressing the Sleep button SLEEP FEATURE DO THIS PRESS SLEEP BUTTON YOU WILL SEE Note Use this function only when cooling is not desired such as for room air circulation or to exhaust stale air on some models Remember to open the vent during this function but keep it closed during cooling for maximum cooling efficiency You can ch...

Page 7: ...p to 24 hours The control will count down the time remaining until start 8 7 5 7 etc The Delay Start Operation automatically selects cooling with maximum Fan speed if Cool Energy Saver or Fan Only was the last mode selected The temperature maintained will be the same as previously set To change the set temperature press COOL then Up or Down arrows until the desired temperature is indicated on the ...

Page 8: ...has ended The display on the remote control indicates the temperature at the remote ONLY NOTE The Remote Sensing function is terminated either by using the Remote Sensing Stop button or the main ON OFF button on the unit 8 Operating Instructions Operating Instructions continued 2009 Electrolux Home Products Inc All rights reserved TO CHANGE TEMPERATURE DISPLAY DO THIS PRESS AND HOLD THE UP DOWN BU...

Page 9: ... to roll through to select another mode After a power outage the unit will memorize the last setting and return the unit to the same setting once power is restored Fresh Air Vent Control on some models The Fresh Air Vent allows the air conditioner to 1 Recirculate inside air Vent Closed see Fig 1 2 Draw fresh air into the room Fresh Air see Fig 2 3 Exchange air from the room Vent Open see Fig 3 Fi...

Page 10: ...checked at least once a month to see if cleaning is necessary Trapped particles in the filter can build up and cause an accumulation of frost on the cooling coils Grasp the filter by the center and pull up and out Wash the filter using liquid dishwashing detergent and warm water Rinse filter thoroughly Gently shake excess water from the filter Be sure filter is thoroughly dry before replacing Or i...

Page 11: ...defrost the coil set to FAN ONLY mode Then set temperature to a higher setting 11 Room temperature below 60 F 16 C Cooling may not occur until room temperature rises above 60 F 16 C Temperature sensing element touching cold coil located behind air filter Straighten away from coil Air from unit does not feel cold enough Compressor shut off by changing modes Wait approximately 3 minutes and listen f...

Page 12: ...pliance or home incurred during installation including but not limited to floors cabinets walls etc 13 Damages caused by services performed by unauthorized service companies use of parts other than genuine Electrolux parts or parts obtained from persons other than authorized service companies or external causes such as abuse misuse inadequate power supply accidents fires or acts of God DISCLAIMER ...

Reviews: