background image

11

2009 Electrolux Home Products, Inc.

All rights reserved.

(continued)

Operating Instructions, CARE & CLEANING

ADDITIONAL THINGS 
YOU SHOULD KNOW

Now that you have mastered the operating procedure, here are more features in 
your control that you should become familiar with. 

Clean your air conditioner occasionally to keep it looking new. 

Be sure to unplug 

the unit before cleaning to prevent shock or fire hazards. 

The "Cool" circuit has an automatic 3 minute time delayed start if the unit is turned 
off and on quickly. This prevents overheating of the compressor and possible circuit 
breaker tripping. The fan will continue to run during this time. 
The control will maintain the set temperature within 2 °F, between 62 °F  and 
86 °F (17 °C and 30 °C).

There is a 2-Second delay for the compressor shutting down when selecting 
FAN ONLY/HEAT. This is to cover the possibility of having to roll through to select 
another mode.
After a power outage, the unit will memorize the last setting and return the unit to 
the same setting once power is restored.

CARE & CLEANING

This unit has three filters, they are filter A, B and C. Grasp the upper panel tab and 
take off the filter A which behind the grill of the back panel (Fig.27). Remove the 
lower filter B and C by loosening the screws. Take down the air inlet grille, then 
remove the air filter as shown in Fig.28 

 29.

Air Filter Cleaning

Wash the filter using liquid dishwashing detergent and warm water. Rinse filter 
thoroughly. Gently shake excess water from the filter. Be sure filter is thoroughly 
dry before replacing. 

Or, instead of washing you may vacuum the filter clean.

If you plan to store the appliance during the winter, cover it with plastic or return
it to its carton.

Winter Storage

Be sure to unplug the air conditioner to prevent shock or fire hazard. The cabinet 
and front may be dusted with an oil-free cloth or washed with a cloth dampened 
in a solution of warm water and mild liquid dishwashing detergent. Rinse 
thoroughly and wipe dry.

Cabinet Cleaning

Never use harsh cleaners, wax or polish on the cabinet front.

Be sure to wring excess water from the cloth before wiping around the controls. 
Excess water in or around the controls may cause damage to the air conditioner.

Fig. 27

Filter A

Filter B

Filter C

Fig. 28

Remove two 
screws and
take the air 
intake grille
down

Slide out the filter B 
behind the side panel

Fig. 29

Remove the filter C 
out from the grille

Operating Instructions

The control is capable of displaying temperature in degrees Fahrenheit or degrees 
Celsius. To convert from one to the other and back, press and hold the "TEMP" 
Up (     ) and Down (    ) buttons together for 3 seconds.

Summary of Contents for 2020252A0673

Page 1: ...020252A0673 June 2009 Product Registration 4 Unit Description 5 Accessories Included 5 Installation Instructions 6 7 Important Safety Instructions 2 3 Air Conditioner Features 8 of your Portable Air Conditioner Operating Instructions 9 11 Care and Cleaning 11 Before You Call 12 Major Appliance Warranty 13 Normal Sounds 4 ...

Page 2: ...t be used in a properly grounded wall receptacle If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker have a qualified electrician install the proper receptacle Do not run air conditioner without outside protective cover in place This could result in mechanical damage within the air conditioner Do not use an extension cord or an a...

Page 3: ...le gases near the unit CAUTION Avoid Injury or damage to the unit or other property READ THIS SECTION BEFORE ATTEMPTING TO OPERATE AIR CONDITIONER Unit must be upright for one hour prior to operating Plug in press RESET The power supply cord contains a current device that senses damage to the power cord To test your power supply cord do the following Plug in the Air Conditioner The power supply co...

Page 4: ... Normal Sounds Today s high efficiency compressors may have a high pitched chatter during the cooling cycle High pitched Chatter Unit may vibrate and make noise because of uneven floor Vibration Sound of Rushing Air At the front of the unit you may hear the sound of rushing air being moved by the fan Gurgle Hiss Gurgling or hissing noise may be heard due to refrigerant passing through evaporator d...

Page 5: ...MIDIFYING DRAIN OUTLET BOTTOM TRAY DRAIN OUTLET EXHAUST HOSE STORAGE WHEN NOT IN USE EXHAUST ADAPTOR A Fig 2 Check all the accessories are included in the package and please refer to the installation instructions for their usage PARTS PARTS NAME QUANTITY Exhaust hose Unit Exhaust Adaptor A Window Exhaust Adaptor B Window Sliding Kit Foam Seal Remote Control Battery For remote control 1 pc 1 set 1 ...

Page 6: ...be placed close to a window or opening so that the warm exhaust air can be ducted outside First position unit on a flat floor and make sure there s a minimum of 12 clearance around the unit and is within the vicinity of a single circuit outlet power source The hose can be extended from its original length of 15 up to 55 but it is the best to keep the length to minimum required Also make sure that ...

Page 7: ...the window slider kit See Fig 19 Cut the adjustable window slider kit if the height of window is less than 26 6 inches Fig 14 6 Cut the foam seal to an appropriate length and seal the open gap between the sliding sash and outer window sash as shown in Fig 21 Fig 12 Foam seal A adhesive type Fig 18 Foam seal adhesive type Installation Instructions Installation Instructions Fig 21 Foam seal Fig 13 W...

Page 8: ...FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation The RESET button is depressed when you want to return to the initial factory settings The LOCK button is depressed to lock the keypad so the settings cannot be changed The ke...

Page 9: ...til the Heat indicator lights 2 Press the Temp buttons for the desired heat setting TIMER OPERATION You can set both delay stop and delay start while unit is in ON position or OFF position When unit is in ON position first press TIMER button to go to delay stop setting then timer off light will illuminate tap or hold the UP arrow or the DOWN arrow to change delay stop timer at 0 5 hour increments ...

Page 10: ...ODE If the display reads EA the room temperature sensor has failed Contact your Authorized Frigidaire Service Center If the display reads ES the evaporator temperature sensor has failed Contact your Authorized Frigidaire Service Center If the display reads E4 the display panel communication has failed Contact your Authorized Frigidaire Service Center If the display reads P1 bottom tray is full Car...

Page 11: ...e lower filter B and C by loosening the screws Take down the air inlet grille then remove the air filter as shown in Fig 28 29 Air Filter Cleaning Wash the filter using liquid dishwashing detergent and warm water Rinse filter thoroughly Gently shake excess water from the filter Be sure filter is thoroughly dry before replacing Or instead of washing you may vacuum the filter clean If you plan to st...

Page 12: ... and off rapidly Dirty air filter air restricted Clean air filter Outside temperature extremely hot Set FAN speed to a faster setting to bring air through cooling coils more frequently Before You Call Air conditioner cooling but room is too warm ice forming on cooling coil behind decorative front Outdoor temperature below 60 F 16 C To defrost the coil set FAN ONLY mode O O Air filter may be dirty ...

Page 13: ...S WRITTEN LIMITED WARRANTY OR ANY IMPLIED WARRANTY SOME STATES AND PROVINCES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSE QUENTIAL DAMAGES OR LIMITATIONS ON THE DURATION OF IMPLIED WARRANTIES SO THESE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU THIS WRITTEN WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS YOU MAY ALSO HAVE OTHER RIGHTS THAT VARY FROM STATE TO STATE If You Need Servic...

Reviews: