background image

Important Safety Instructions

2

2009 Electrolux Home Products, Inc.

All rights reserved.

NOTE:

This USE & CARE MANUAL provides specific operating instructions for your model. Use the room air conditioner only as 
instructed in this USE & CARE MANUAL. These instructions are not meant to cover every possible condition and situation that 
may occur. Common sense and caution must be practiced when installing, operating, and maintaining any appliance. 

WARNING

For Your Safety

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any
other appliance. Read product labels for flammability and other warnings. 

WARNING

Prevent Accidents

To reduce the risk of fire, electrical shock, or injury to persons when using your air conditioner,
follow basic precautions, including the following: 

Be sure the electrical service is adequate for the model you have chosen. This information
can be found on the serial plate, which is located on the side of the cabinet.

If the air conditioner is to be installed in a window, you will probably want to clean both
sides of the glass first.

Be sure the air conditioner has been securely and correctly installed according to the
installation instructions in this manual. Save this manual for possible future use in 
removing or reinstalling this unit. 

The complete electrical rating of your new protable air conditioner is stated on the serial 
plate. Refer to the rating when checking the electrical requirements. 

Be sure the air conditioner is properly grounded. To minimize shock and fire hazards,
proper grounding is important. The power cord is equipped with a three-prong grounding
plug for protection against shock hazards.  
Your air conditioner must be used in a properly grounded wall receptacle. If the wall
receptacle you intend to use is not adequately grounded or protected by a time delay fuse
or circuit breaker, have a qualified electrician install the proper receptacle.  

Do not run air conditioner without outside protective cover in place. This could result in
mechanical damage within the air conditioner.  

Do not use an extension cord or an adapter plug.

WARNING

Electrical Information

WARNING

Avoid fire hazard or electric shock. Do not
use an extension cord or an adaptor plug. Do
not remove any prong from the power cord.

NOTE:

The power supply cord with
this air conditioner contains a current
detection device designed to reduce the risk
of fire.
Please refer to the section ‘Operation of
Current Device’ for details.
In the event that the power supply cord is
damaged, it cannot be repaired. It must be
replaced with a cord from the product
manufacturer.

Grounding type wall
receptacle

Do  not,  under  any
circumstances, cut,
remove, or bypass the
grounding prong.

Power supply cord
with 3-prong grounding
plug and current
detection device

SAFETY PRECAUTIONS

This air conditioner contains no user-serviceable parts. Always call an authorized Electrolux servicer for repairs.
Do not insert or place fingers or objects into the air discharge area on top of the unit.
Do not start or stop the air conditioner by unplugging the power cord or turning off the power at the electrical box.
Do not cut or damage the power cord.
If the power cord is damaged, it should only be replaced by an authorized Electrolux servicer.
In the event of a malfunction (sparks, burning smell, etc.), immediately stop the operation, disconnect the power cord, and call an authorized 
Electrolux servicer.
Do not operate the air conditioner with wet hands.
Do not pull on the power cord.
Do not drink any water that is drained from the air conditioner.

DANGER!  Avoid Serious Injury or Death 

Summary of Contents for 2020252A0673

Page 1: ...020252A0673 June 2009 Product Registration 4 Unit Description 5 Accessories Included 5 Installation Instructions 6 7 Important Safety Instructions 2 3 Air Conditioner Features 8 of your Portable Air Conditioner Operating Instructions 9 11 Care and Cleaning 11 Before You Call 12 Major Appliance Warranty 13 Normal Sounds 4 ...

Page 2: ...t be used in a properly grounded wall receptacle If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker have a qualified electrician install the proper receptacle Do not run air conditioner without outside protective cover in place This could result in mechanical damage within the air conditioner Do not use an extension cord or an a...

Page 3: ...le gases near the unit CAUTION Avoid Injury or damage to the unit or other property READ THIS SECTION BEFORE ATTEMPTING TO OPERATE AIR CONDITIONER Unit must be upright for one hour prior to operating Plug in press RESET The power supply cord contains a current device that senses damage to the power cord To test your power supply cord do the following Plug in the Air Conditioner The power supply co...

Page 4: ... Normal Sounds Today s high efficiency compressors may have a high pitched chatter during the cooling cycle High pitched Chatter Unit may vibrate and make noise because of uneven floor Vibration Sound of Rushing Air At the front of the unit you may hear the sound of rushing air being moved by the fan Gurgle Hiss Gurgling or hissing noise may be heard due to refrigerant passing through evaporator d...

Page 5: ...MIDIFYING DRAIN OUTLET BOTTOM TRAY DRAIN OUTLET EXHAUST HOSE STORAGE WHEN NOT IN USE EXHAUST ADAPTOR A Fig 2 Check all the accessories are included in the package and please refer to the installation instructions for their usage PARTS PARTS NAME QUANTITY Exhaust hose Unit Exhaust Adaptor A Window Exhaust Adaptor B Window Sliding Kit Foam Seal Remote Control Battery For remote control 1 pc 1 set 1 ...

Page 6: ...be placed close to a window or opening so that the warm exhaust air can be ducted outside First position unit on a flat floor and make sure there s a minimum of 12 clearance around the unit and is within the vicinity of a single circuit outlet power source The hose can be extended from its original length of 15 up to 55 but it is the best to keep the length to minimum required Also make sure that ...

Page 7: ...the window slider kit See Fig 19 Cut the adjustable window slider kit if the height of window is less than 26 6 inches Fig 14 6 Cut the foam seal to an appropriate length and seal the open gap between the sliding sash and outer window sash as shown in Fig 21 Fig 12 Foam seal A adhesive type Fig 18 Foam seal adhesive type Installation Instructions Installation Instructions Fig 21 Foam seal Fig 13 W...

Page 8: ...FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation The RESET button is depressed when you want to return to the initial factory settings The LOCK button is depressed to lock the keypad so the settings cannot be changed The ke...

Page 9: ...til the Heat indicator lights 2 Press the Temp buttons for the desired heat setting TIMER OPERATION You can set both delay stop and delay start while unit is in ON position or OFF position When unit is in ON position first press TIMER button to go to delay stop setting then timer off light will illuminate tap or hold the UP arrow or the DOWN arrow to change delay stop timer at 0 5 hour increments ...

Page 10: ...ODE If the display reads EA the room temperature sensor has failed Contact your Authorized Frigidaire Service Center If the display reads ES the evaporator temperature sensor has failed Contact your Authorized Frigidaire Service Center If the display reads E4 the display panel communication has failed Contact your Authorized Frigidaire Service Center If the display reads P1 bottom tray is full Car...

Page 11: ...e lower filter B and C by loosening the screws Take down the air inlet grille then remove the air filter as shown in Fig 28 29 Air Filter Cleaning Wash the filter using liquid dishwashing detergent and warm water Rinse filter thoroughly Gently shake excess water from the filter Be sure filter is thoroughly dry before replacing Or instead of washing you may vacuum the filter clean If you plan to st...

Page 12: ... and off rapidly Dirty air filter air restricted Clean air filter Outside temperature extremely hot Set FAN speed to a faster setting to bring air through cooling coils more frequently Before You Call Air conditioner cooling but room is too warm ice forming on cooling coil behind decorative front Outdoor temperature below 60 F 16 C To defrost the coil set FAN ONLY mode O O Air filter may be dirty ...

Page 13: ...S WRITTEN LIMITED WARRANTY OR ANY IMPLIED WARRANTY SOME STATES AND PROVINCES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSE QUENTIAL DAMAGES OR LIMITATIONS ON THE DURATION OF IMPLIED WARRANTIES SO THESE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU THIS WRITTEN WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS YOU MAY ALSO HAVE OTHER RIGHTS THAT VARY FROM STATE TO STATE If You Need Servic...

Reviews: