background image

Before calling for service, review this list. It may save you time and expense. This list includes common occurrences that are not 
the result of defective workmanship or materials in this appliance.

OCCURRENCE

SOLUTION

Wall plug disconnected. Push plug firmly into wall outlet.

House fuse blown or circuit breaker tripped. Replace fuse with time delay type or reset circuit breaker.

Water in the bucket has reached its preset level. Dehumidifier automatically turns off when this 
occurs. Empty bucket and return bucket to position. 

The dryness level you selected has been reached. Dehumidifier automatically shuts off when selected 
amount of moisture has been removed from the air. If you want to remove more moisture, Select 
'CONTINUOUS' by using the humidity button or knob. After the dehumidifier starts, reset the control 
to the desired setting.

Bucket not installed properly. See “Removing Collected Water“.

Dehumidifier is not turned on. Turn unit on. 

“BUCKET FULL“ light is on. Remove bucket, empty water and re-install correctly.

DEHUMIDIFIER DOES NOT 
OPERATE.

DEHUMIDIFIER IS OPERATING 
BUT ROOM IS NOT DRY ENOUGH. 

Humidity setting is too high. Press the HUMIDITY button or rotate knob to a lower setting or choose 
CONTINUOUS for maximum dryness.

Dehumidifier has been installed or restarted recently. The higher the moisture in the room air, the 
longer it takes for the room air to become dry.

Dehumidifier does not have sufficient clearance to operate. Air flow to front grill is blocked. See 
“Selecting a Location“.

Room temperature is too low. Unit will not operate satisfactorily if the room temperature is below 
41 °F(5 °C). See “Operating Conditions“.

Refer to causes under DEHUMlDIFIER RUNS TOO MUCH.

FROST APPEARS ON COILS ABOVE
BUCKET OR DRIP TRAY.

Dehumidifier has been turned on recently. This is normal due to refrigerant rushing through the coil. 
Frost will usually disappear within 60 minutes.

Room Temperature is too low. All models will operate satisfactorily at temperatures greater than 
41 °F (5 °C). 

FAN NOISE.

Air is moving through the dehumidifier. This is a normal sound.

If These Solutions Fail, Call 1-800-944-9044 For Frigidaire Service.

Before You Call

9

2009 Electrolux Home Products, Inc.

All rights reserved.

DEHUMIDIFIER RUNS TOO MUCH.

Air movement through dehumidifier is blocked. Grill may be dirty. Use brush attachment of vacuum 
cleaner to clean grill. See “Care and Cleaning“. Dehumidifier must be placed in a space that does 
not restrict air flowing into the rear coil or out of the front grill.

O

Dehumidifier has been installed or restarted recently. The higher the moistuire in the room, the longer 
the dehumidifier will operate.

Windows or doors near dehumidifier are open to outdoors. Close all windows or doors to outside.

Area to be dehumidified is too large. Check with your dealer to see if capacity is adequate.

Dehumidifier is in the CONT mode and will remain on in this mode use the humidity button or knob 
to set a RH% higher level.

Summary of Contents for 2020266A0107

Page 1: ...rigidaire ca Canada 1 800 265 8352 All about the Use Care of your Dehumidifier 2020266A0107 June 2009 Location 2 How It Works 2 Important Safety Instructions 2 Care And Cleaning 8 Storage Before You Call 9 Major Appliance Warranty 10 8 3 7 Operating Instructions ...

Page 2: ...receptacle WARNING Electrical Information Do not pinch bend or knot the power cord NOTE This USE CARE MANUAL provides specific operating instructions for your model Use the room air conditioner only as instructed in this USE CARE MANUAL These instructions are not meant to cover every possible condition and situation that may occur Common sense and caution must be practiced when installing operatin...

Page 3: ...minate If the BUCKET FULL light is on remove the bucket and re install to reset the float switch NOTE Unit must be upright for one hour prior to operating NOTE 2 To turn the unit on press the ON OFF button The unit will run in the factory setting of CONTINUOUS and high fan speed In the Continuos Mode the unit will only display CO and not the room humidity It is recommended you leave the unit runni...

Page 4: ...o remove and clean the filter Once the filter has been cleaned to extinguish the light simply press the FILTER button 3 After a few days when the Relative Humidity has declined press the HUMIDITY or buttons to choose a value between 35 to 85 so the room is kept at a comfortable concentration Pressing the or buttons will change the humidity selection in 5 increments After you have set the desired h...

Page 5: ...tart the fan speed and humidity maintained will be the same as previously setting After TIMER setting finishs pressing TIMER button again at any time will cancel the TIMER function The Delay Start Stop Feature will work until the unit either starts ro stops Once that happens the above steps have to be repeated again 5 2009 Electrolux Home Products Inc All rights reserved Operating Instructions con...

Page 6: ...LL indicator light will illuminate b Do not move the unit at this point otherwise water may spill on the floor c Press sides of bucket gently to unclip the bucket from the unit d Remove the bucket as shown in the photographs below and empty the bucket e Replace the empty bucket back into the unit and once seated correctly the unit will start up again f You should hear a click when the bucket is in...

Page 7: ... is secure so there are no leaks g Direct the hose toward the drain making sure that there are no kinks that will stop the water flowing h Place the end of the hose into the drain i Place the bucket back in the unit and make sure that it is located correctly fig 4 j Select the desired humidity setting and fan speed on the unit for continuous draining to start If the unit stops operating check that...

Page 8: ... the filter remove Bucket then pull filter downwards c Wash the filter with clean water then dry d Re install the filter replace Bucket 2 Cabinet a Dust cabinet with an oil free cloth or using a damp cloth b Vacuum grill using brush attachment 3 Water Bucket a Clean bucket with warm water and detergent Storage When unit is not in use unplug and use the cord wrap shown for your model type 2 1 ...

Page 9: ... to become dry Dehumidifier does not have sufficient clearance to operate Air flow to front grill is blocked See Selecting a Location Room temperature is too low Unit will not operate satisfactorily if the room temperature is below 41 F 5 C See Operating Conditions Refer to causes under DEHUMlDIFIER RUNS TOO MUCH FROST APPEARS ON COILS ABOVE BUCKET OR DRIP TRAY Dehumidifier has been turned on rece...

Page 10: ...pliance or home incurred during installation including but not limited to floors cabinets walls etc 13 Damages caused by services performed by unauthorized service companies use of parts other than genuine Electrolux parts or parts obtained from persons other than authorized service companies or external causes such as abuse misuse inadequate power supply accidents fires or acts of God DISCLAIMER ...

Reviews: