background image

6

30" GAS RANGE INSTALLATION INSTRUCTIONS

(For Models with Sealed Top Burners)

6. Assembly of the Burner Caps and Burner
Grates:

It is very important to makes sure that all of the  Surface Burner
Caps and Surface Burner Grates are installed correctly and in
the correct locations.

Please Note: The burner heads are secured to the
cooktop. THE COOKTOP IS NOT REMOVABLE. 

Do not

attempt to remove or lift the cooktop.

Where a standard two-prong wall receptacle is encountered,
it is the personal responsibility and obligation of the customer
to have it replaced with a properly grounded three-prong wall
receptacle.

DO NOT, UNDER ANY CIRCUMSTANCES, CUT OR REMOVE
THE THIRD (GROUND) PRONG FROM THE POWER CORD.

 PLEASE READ CAREFULLY!  

For personal

safety, this product must be properly grounded.

REMEMBER — DO NOT ALLOW SPILLS, FOOD,
CLEANING AGENTS OR ANY OTHER MATERIAL TO
ENTER THE GAS ORIFICE HOLDER OPENING. 
Always
keep the Burner Caps and Burner Heads in place whenever
the surface burners are in use.

5. Read these electrical connection details first
then connect electricity to range.

 Before servicing, disconnect electrical

supply at circuit breaker, fuse or power cord.

Electric Requirements:

 

A dedicated, properly grounded and

polarized branch circuit protected by a 15 amp. circuit breaker
or time delay fuse. See serial plate for proper voltage.

Extension Cord Precautions:
Because of potential safety hazards under certain conditions,
we strongly recommend against the use of any extension
cord. However, if you still elect to use an extension cord, it is
absolutely necessary that it be a UL listed 3-wire grounding
type appliance extension cord and that the current carrying
rating of the cord in amperes be equivalent to or greater than
the branch circuit rating. Such extension cords are obtainable
through your local service organization.

Grounding Instructions

The power cord of this appliance is equipped with a
3-prong (grounding) plug which mates with a standard
3-prong grounding wall receptacle to minimize the possibility
of electric shock hazard from this appliance.  The customer
should have the wall receptacle and circuit checked by a
qualified electrician to make sure the receptacle is properly
grounded and polarized.

Summary of Contents for 316259359

Page 1: ...jury or death FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach you...

Page 2: ...llappliances Neverleave the oven door open when the range is unattended Stepping leaning or sitting on the doors ordrawersofthisrangecanresultinseriousinjuriesand can also cause damage to the range Do not store items of interest to children in the cabinets above the range Children could be seriously burned climbing on the range to reach items To eliminate the need to reach over the surface burners...

Page 3: ...rovided for installation in wood or cement fastened to either the floor or wall When installed to the wall make sure that screws completely penetrate dry wall and are secured in wood or metal When fastening to the floor or wall be sure that screws do not penetrate electrical wiring or plumbing A LocatetheBracketUsingtheTemplate Bracketmay belocatedoneithertheleftorrightsideoftherange Use the infor...

Page 4: ...essure to the regulator should be no more than 14 inches of water column pressure The inlet pressure to the regulator must be at least 1 inch greater than regulator manifold pressure Examples If regulator is set for natural gas 4 inch manifold pressure inlet pressure must be at least 5 inches if regulator has been convertedforLP Propanegas10inchmanifoldpressure inlet pressure must be at least 11 i...

Page 5: ...ure is 4 For LP Propane Gas the manifold pressure is 10 DO NOT allow regulator to turn on pipe when tightening fittings a Installanexternalmanualgasshut offvalvetogassupply lineinanaccessiblelocationoutsideoftherange Besure you know where and how to shut off the gas supply to the range b Install1 2 flareunionadaptertopressureregulatorusing NO MORE THAN 15ft lbs of torque NOTE Be sure to stabilize ...

Page 6: ...connection details first then connect electricity to range Before servicing disconnect electrical supply at circuit breaker fuse or power cord Electric Requirements A dedicated properly grounded and polarizedbranchcircuitprotectedbya15amp circuitbreaker or time delay fuse See serial plate for proper voltage Extension Cord Precautions Becauseofpotentialsafetyhazardsundercertainconditions we strongl...

Page 7: ...ff Adjust flame until you can quickly turn knob from LITE to LOWEST POSITION without extinguishing the flame Flame should be as small as possible without going out Note Air mixture adjustment is not required on surface burners Test to verify if LOW setting should be adjusted a Push in and turn control to LITE until burner ignites b Push in and quickly turn knob to LOWEST POSITION c If burner goes ...

Page 8: ... Youridentificationplatealsotellsyoutheratingoftheburners the type of fuel and the pressure the range was adjusted for when it left the factory 11 Air Shutter Broil Burner The approximate flame length of the broil burner is 1 inch distinct inner blue flame To determine if the broil burner flame is proper set the oven to broil Iftheflameisyellowincolor increaseairshutteropeningsize See 2 in illustr...