4.  Test all connections by brushing on a soapy water solution.

 NEVER test

for gas leaks with an open flame.

GENERAL INSTALLATION

1. Connect the exhaust duct to outside exhaust system (see pages 3

and 4).  Use duct tape to seal all joints.

2. With the dryer in its final position, adjust one or more of the legs

until the dryer is resting solid on all four legs. Place a level on top
of the dryer.

 The dryer MUST be level and resting solid on all

four legs.

3. Plug the power cord into a grounded outlet. 

NOTE:

 Check to

ensure the power is off at circuit breaker/fuse box before plugging
the power cord into the outlet.

4. Turn on the power at the circuit breaker/fuse box.

 

Before operating the dryer, make sure the

dryer area is clear and free from combustible materials,
gasoline, and other flammable vapors. Also see that
nothing (such as boxes, clothing, etc.) obstructs the flow
of combustion and ventilation air.

5. Run the dryer through a cycle check for proper operation.

NOTE:

 On gas dryers, before the burner will light, it is necessary

for the gas line to be bled of air. If the burner does not light within
45 seconds the first time the dryer is turned on, the safety switch
will shut the burner off. If this happens, turn the timer to "OFF" and
wait 5 minutes before making another attempt to light.

6. If your dryer does not operate, please review the "Avoid Service

Checklist" located in your Use and Care Guide before calling for
service.

7. Place these instructions in a location near the dryer for future

reference.

NOTE:

 A wiring diagram/tech sheet is in an envelope attached to

  the inside side panel of the dryer by the blower housing.

Pedestal

A pedestal accessory, 

Model No.

 

APWD15W

, specifically designed

for this dryer may be used when elevating the dryer for ease of use.
Failure to  use accessories certified by the manufacturer could result
in personal injury, property damage or damage to the dryer.

REPLACEMENT PARTS

If replacements parts are needed for your dryer, contact the source
where you purchased your dryer, call 1-800-944-9044, or visit our website,
www.frigidaire.com, for the Frigidaire Company Authorized Parts
Distributor nearest you.

 Label all wires prior to disconnection when servicing controls.

Wiring errors can cause improper and dangerous operation. Verify proper
operation after servicing.

 Destroy the carton and plastic bags after the dryer is

unpacked. Children might use them for play. Cartons covered with rugs,
bedspreads, or plastic sheets can become airtight chambers causing
suffocation. Place all materials in a garbage container or make materials
inaccessible to children.

 The instructions in this manual and all other literature included

with this dryer are not meant to cover every possible condition and situation
that may occur. Good safe practice and caution 

MUST

 be applied when

installing, operating and maintaining any appliance.

4. Thread a U.L. approved 30 amp power cord, NEMA 14-30 type ST or

SRDT through the strain relief.

5. Attach the green power cord ground wire to the cabinet with the

green ground screw.

6. Attach the white (neutral) power cord conductor from the power

cord and the neutral ground wire from the dryer harness to the
silver-colored center terminal on the terminal block. Tighten the
screw securely.

7. Attach the red and black power cord conductors to the outer

brass-colored terminals on the terminal block.

  Do not make a sharp bend or crimp wiring/conductor

at the connections.

8. Tighten the screws securing the cord restraint firmly against the

power cord.

9. Tighten the strain relief nut securely so the strain relief does not

turn.

10. Reinstall the terminal block access cover.

                         GAS CONNECTION

1. Remove the shipping cap from gas pipe at the rear of the dryer.

NOTE: DO NOT

 connect the dryer to L.P. gas service without

converting the gas valve. An L.P. conversion kit must be installed

     by a qualified gas technician.

2. Connect a 1/2 inch (1.27 cm) I.D. semi-rigid or approved pipe from

gas supply line to the 3/8 inch (0.96 cm) pipe located on the back

     of the dryer (see pages 6 and 7). Use a 1/2 inch to 3/8 inch (1.27
     cm to 0.96 cm) reducer for a connection. Apply an approved

thread sealer that is resistant to the corrosive action of liquefied
gases on all pipe connections.

3. Open the shutoff valve in the gassupply line to allow gas to flow
     through the pipe.

STRAIN

RELIEF

MOUNTING

BRACKET

NUT

TIGHTEN
NUT
TO THESE
THREADS

POWER
CORD

RED

WHITE

BLACK

TERMINAL
BLOCK

SILVER TERMINAL

GREEN
GROUND
SCREW

GREEN POWER CORD
GROUND WIRE

NEUTRAL
GROUND
WIRE

RED

BLACK

WHITE

GREEN

30 AMP NEMA 14-30 TYPE SRDT OR ST

TYPICAL 4
CONDUCTOR

TYPICAL 4
CONDUCTOR

ELECTRICAL CONNECTIONS FOR 4-WIRE SYSTEM

NON-CANADIAN  ELECTRIC Dryer

1. Remove the screws securing the terminal block access cover and
     the strain relief mounting bracket located on the back of the dryer

upper corner.

2. Install a U.L. approved strain relief in the entry hole of the mounting

bracket. Finger tighten the nut only at this time.

3. Remove the ground wire from the green ground screw located

above the terminal block.

VALVE OPEN / GAS FLOW POSITION

Summary of Contents for AEQ6700FS - 27" Electric Dryer

Page 1: ...TA La alimentación eléctrica para la secadora deberá cumplir con los códigos y reglamentos locales y con la última edición del Código Eléctrico Nacional ANSI NFPA 70 NOTA La alimentación de gas para la secadora deberá cumplir con los códigos y reglamentos locales y con la última edición del Código Nacional para Gases Combustibles ANSI Z223 1 NOTA La secadora está clasificada para USO DOMESTICO sol...

Page 2: ...receptacle to be located so the power supply cord is accessible when the dryer is in the installed position NOTE Do not under any circumstances remove grounding prong from plug GROUNDING PRONG EXHAUST SYSTEM REQUIREMENTS Use only 4 inch 10 2 cm diameter minimum rigid or flexible metal duct and approved vent hood which has a swing out damper s that open when the dryer is in operation When the dryer...

Page 3: ...column If the system back pressure is less than 0 75 inches of water column the system is acceptable If the manometer reading is higher than 0 75 inches of water column the system is too restrictive and the installation is unacceptable Although vertical orientation of the exhaust system is acceptable certain extenuating circumstances could affect the performance of the dryer Only the rigid metal d...

Page 4: ...1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 27 68 58 5 13 97 29 75 57 13 34 29 5 12 70 2 6 03 3 8 34 86 36 35 88 90 2 25 5 72 Stacked Dryer Installation Dimensions To front of cabinet 28 25 71 76 To clear kobs 28 75 73 03 To clear door 29 5 74 93 To clear open door 53 134 62 13 5 34 29 27 68 58 Ele...

Page 5: ... MUST terminate outside the enclosure with the termination securely fastened to the mobile home structure 3 When installing a gas dryer into a mobile home a provision must be made for outside make up air This provision is to be not less than twice the area of the dryer exhaust outlet 4 This dryer MUST be fastened to the floor Mobile Home Installation Kit No 346764 is available from your dealer 5 R...

Page 6: ...door DRYER DOOR REVERSAL INSTRUCTIONS Be sure to wear gloves while reversing the door assembly 1 Open the dryer door 2 Remove the two 10 16x 50 that secures the door assembly to the front panel NOTE Remove the bottom screw first Support the door assembly firmly before removing the top screw 3 Remove the door assembly by lifting and pulling toward the center of the unit opening 4 Place door assembl...

Page 7: ... 1 The dryer MUST be connected to a grounded metal permanent wiring system or an equipment grounding conductor must be run with the circuit conductors and connected to the equipment grounding terminal or lead on the appliance Canadian ELECTRIC Dryer DANGER Improper connection of the equipment grounding conductor can result in a risk of electrical shock Check with a licensed electrician if you are ...

Page 8: ...gs bedspreads or plastic sheets can become airtight chambers causing suffocation Place all materials in a garbage container or make materials inaccessible to children The instructions in this manual and all other literature included with this dryer are not meant to cover every possible condition and situation that may occur Good safe practice and caution MUST be applied when installing operating a...

Page 9: ...os los accesorios de tubería machos DEBEN ser instalados aguas abajo del flujo de aire NOTA No saque por ESPIGA SecadorasaGAS CIRCUITO Circuito individual derivado de 15 amp con fusibles de 15 amp de retardo máximo o disyuntor Utilice circuitos de fusibles separados para la lavadora y la secadora No opere una lavadora y una secadora en el mismo circuito ALIMENTACIÓN ELÉCTRICA Corriente alterna mon...

Page 10: ...87 1 cm 387 1 cm 387 1 cm 387 1 cm2 2 2 2 2 REQUERIMIENTOS DEL SUMINISTRO DE GAS Reemplace la tubería de conexión de cobre que no está recubrida con plástico El latón inoxidable o recubrido con plástico DEBE SER utilizado 1 La instalación DEBE hacerse cumplir con los códigos locales o en ausencia de los mismos de acuerdo con los estandares del National Fuel Gas Code Código Nacional para Gases Comb...

Page 11: ... 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 Al frente del gabinete 28 25 71 76 A las perillas claras 28 75 73 03 A las perillas puerta 29 5 74 93 En ei claro abra la puerta 53 134 62 ...

Page 12: ... adquirir con su distribuidor 5 Vealaspáginas2y3paraotrosrequísitosimportantesdeventilación 6 La instalación DEBE cumplir con las estándares aplicables de la Manufactured Home Construction Safety Standard Estándares de Seguridad y Construcción de Casas Prefabricadas Título 24 CFR Parte 32 80 del Reglamento Federal o cuando dichos estándares noseanaplicables sedebencomplirconlosestándaresdelaAmeric...

Page 13: ...puerta 1 Abre la puerta de la secadora 2 Retire los dos tornillos No 10 de 16x 50 que aseguran la puerta al panel frontal NOTA Retire primero el tornillo de abajo Sostenga firmemente la puerta antes de retirar el tornillo de arriba 3 Retire la puerta levantándola y tirando hacia el centro de la unidad 4 Coloque la puerta hacia abajo sobre una superficie plana y suave 5 Retire los dos tapones redon...

Page 14: ...e aluminio con un cordón y un enchufe de cobre o viceversa Se produce una reacción química entre el cobre y el aluminio que puede causar cortacircuitos El cableado y tomacorriente apropiado es un cordón eléctrico equipado con conductores de cobre con un tomacorriente con conductores de cobre NOTA Las secadoras que operan con un suministro de energía de 208 voltios usarán más tiempo de secado que a...

Page 15: ...cados por el fabricante podía dar lugar a daños corporales a daños materiales o a daño a la secadora Si necesita obtener piezas de recambio para su secadora póngase en contacto con el distribuidor donde compró su secadora llame 1 800 944 9044 o visitan nuestros website www frigidaire com para la Distribuidor Autorizada Company de las Piezas de Frigidaire más cercana usted Cuando se reparan los con...

Reviews: