ELECTRICAL INSTALLATION

ELECTRIC Dryer

 The following are specific requirements for proper and

safe electrical installation of your dryer. Failure to follow these
instructions can create electrical shock and/or a fire hazard.

 

This appliance MUST be properly grounded.

 

Electrical

shock and/or a fire can result if the dryer is not properly grounded.

Follow the instructions in this manual for proper grounding.

 

Do not use an extension cord with this dryer.

 Some

extension cords are not designed to withstand the amounts of electrical
current this dryer utilizes and can melt, creating electrical shock and/or fire
hazard. Locate the dryer within reach of the receptacle for the length
power cord to be purchased, allowing some slack in the cord. Refer to the
pre-installation requirements in this manual for the proper power cord to be
purchased.

 

A U.L. approved strain relief must be installed onto power

cord. 

If the strain relief is not attached, the cord can be pulled out of the

dryer and can be cut by any movement of the cord, resulting in electrical
shock.

 

Do not use an aluminum wired receptacle with a copper

wired power cord and plug (or vice versa).

 A chemical reaction occurs

between copper and aluminum and can cause electrical shorts. 

The proper

wiring and receptacle is a copper wired power cord with a copper
wired receptacle.

NOTE:

 Dryers operating on 208 volt power supply will have longer

drying times than operating on 240 volt power supply.

GROUNDING REQUIREMENTS

NON-CANADIAN ELECTRIC Dryer

 Improper connection of the equipment grounding conductor

can result in a risk of electrical shock. Check with a licensed electrician if you
are in doubt as to whether the appliance is properly grounded.

For a grounded, cord-connected dryer:

1. The dryer 

MUST

 be grounded. In the event of a malfunction or

breakdown, grounding will reduce the risk of electrical shock by a path
of least resistance for electrical current.

2. If your dryer is equipped with a power supply cord having an equipment-

grounding conductor and a grounding plug, the plug 

MUST

 be plugged

into an appropriate, copper wired receptacle that is properly installed
and grounded in accordance with all local codes and ordinances. If in
doubt, call a licensed electrician.

  Do not modify plug provided with

the appliance.

For a permanently connected dryer:

1. The dryer 

MUST

 be connected to a grounded metal, permanent wiring

system; or an equipment grounding conductor must be run with the
circuit conductors and connected to the equipment-grounding terminal
or lead on the appliance.

Canadian  ELECTRIC Dryer

DANGER

 Improper connection of the equipment grounding conductor

can result in a risk of electrical shock. Check with a licensed electrician if you
are in doubt as to whether the appliance is properly grounded.

For a grounded, cord-connected dryer:
1. The dryer must be grounded. In the event of a malfunction or breakdown,

grounding will reduce the risk of electrical shock by a path of least
resistance for electrical current.

2. Since your dryer is equipped with a power supply cord having an

equipment-grounding conductor and a grounding plug, the plug must
be plugged into an appropriate outlet that is properly installed and
grounded in accordance with all local codes and ordinances. If in doubt,
call a licensed electrician.  

Do not modify plug provided with the

appliance.

ALL GAS Dryers

This dryer is equipped with a three-prong (grounding) plug for your
protection against shock hazard and should be plugged directly into a
properly grounded three-prong receptacle. Do not cut or remove the
grounding prong from this plug.

ELECTRICAL CONNECTIONSFOR 3-WIRE SYSTEM

NON-CANADIAN  ELECTRIC Dryer

1. Remove the screws securing the terminal block access cover and the

strain relief mounting bracket located on the back of the dryer upper
corner.

2. Install a U.L. approved strain relief into the power cord entry hole of the

mounting bracket. Finger tighten the nut only at this time.

3. Thread a U.L. approved 30 amp. power cord, NEMA 10-30 type SRDT,

through the strain relief.

4. Attach the power cord neutral (center wire) conductor to the silver

colored center terminal on the terminal block. Tighten the screw securely.

5. Attach the remaining two power cord outer conductors to the outer

brass colored terminals on the terminal block. Tighten both screws
securely.

 Do not make a sharp bend or crimp wiring/ conductor

at connections.

6. Reattach the strain relief mounting bracket to the back of the dryer

with two screws. Tighten screws securely.

POWER CORD

TIGHTEN NUT
TO THESE
THREADS

STRAIN
RELIEF
MOUNTING
BRACKET

GREEN
GROUND
SCREW

NUT

NEUTRAL
GROUND
WIRE

SILVER TERMINAL

7. Tighten the screws securing the cord restraint firmly against the power

cord.

8. Tighten the strain relief nut securely so the strain relief does not turn.

9. Reinstall the terminal block cover.

Summary of Contents for AEQ7000CES1

Page 1: ...nte du Code ANSI NFPA 70 ou au Canada le Code canadien d électricité ACNOR C22 1 partie1 REMARQUE L alimentation en gaz de la sécheuse doit respecter les codes et ordonnances locaux ainsi que l édition la plus récente du Code ANSI Z223 1 ou au Canada le code CAN ACG B149 1 2000 REMARQUE La sécheuse est conçue conformément au code ANSI Z 21 5 1 ou ANSI UL 2158 CAN ACG C22 2 No 112 l édition la plus...

Page 2: ...tacle to be located so the power supply cord is accessible when the dryer is in the installed position Canada NEMA 14 30R receptacle NOTE Do not under any circumstances remove grounding prong from plug GROUNDING PRONG EXHAUST SYSTEM REQUIREMENTS Use only 4 inch 10 2 cm diameter minimum rigid or flexible metal duct and approved vent hood which has a swing out damper s that open when the dryer is in...

Page 3: ...column If the system back pressure is less than 0 75 inches of water column the system is acceptable If the manometer reading is higher than 0 75 inches of water column the system is too restrictive and the installation is unacceptable Although vertical orientation of the exhaust system is acceptable certain extenuating circumstances could affect the performance of the dryer Only the rigid metal d...

Page 4: ...1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 27 68 58 5 13 97 29 75 57 13 34 29 5 12 70 2 6 03 3 8 34 86 36 35 88 90 2 25 5 72 Stacked Dryer Installation Dimensions To front of cabinet 28 25 71 76 To clear kobs 28 75 73 03 To clear door 29 5 74 93 To clear open door 53 134 62 13 5 34 29 27 68 58 Ele...

Page 5: ...e the enclosure with the termination securely fastened to the mobile home structure 3 When installing a gas dryer into a mobile home a provision must be made for outside make up air This provision is to be not less than twice the area of the dryer exhaust outlet 4 This dryer MUST be fastened to the floor Mobile Home Installation Kit No 346764 is available from your dealer 5 Refer to pages 2 and 3 ...

Page 6: ...r door from the outer door Remove bottom screw first Round plug Round plug Rectangular plug 6 7 7 Remove the two hinge attachment screws one square plug two round plugs and one metal strike from the inner door 8 Rotate the hinge and reattach it to the opposite side of the inner door 9 Dispose of the old metal strike and install the new strike included in the literature pack in the opposite side of...

Page 7: ...d dryer 1 The dryer MUST be connected to a grounded metal permanent wiring system or an equipment grounding conductor must be run with the circuit conductors and connected to the equipment grounding terminal or lead on the appliance Canadian ELECTRIC Dryer DANGER Improper connection of the equipment grounding conductor can result in a risk of electrical shock Check with a licensed electrician if y...

Page 8: ...gs bedspreads or plastic sheets can become airtight chambers causing suffocation Place all materials in a garbage container or make materials inaccessible to children The instructions in this manual and all other literature included with this dryer are not meant to cover every possible condition and situation that may occur Good safe practice and caution MUST be applied when installing operating a...

Page 9: ...ue de clapets qui s ouvrent lorsque la sécheuse fonctionne Quand la sécheuse s arrête les clapets se fermentautomatiquementpouréviterlescourantsd airetl entrée d insectes ou de rongeurs Afin de ne pas obstruer l évacuation de l air laisser une distance minimum de 30 5 cm 12 po entre la grille de sortie et le sol ou tout autre obstacle Les mises en garde qui suivent se rapportent directement au fon...

Page 10: ...on et ainsi réduire la capacité d évacuation du circuit Un circuit d évacuation comprimé ou ondulant peut voir sa capacité d évacuation réduite Il faut inspecter le circuit d évacuation et le nettoyer au moins à tous les 18 mois d utilisation normale Plus la sécheuse est utilisée plus il faut procéder souvent à une vérification du bon fonctionnement du circuit d évacuation et du couvercle du regis...

Page 11: ...NSTALLER LA SÉCHEUSE 1 Dans un endroit exposé à un écoulement d eau ou aux conditions atmosphériques 2 Dansunendroitoùelleseraitencontactavecdesrideaux draperies ou tout ce qui obstruera le flux d air de combustion et de ventilation 3 Sur un tapis Le plancher DOIT être ferme et présenter une pente de 2 54 cm 1 po au maximum INSTALLATION DANS UNE ALCÔVE OU UN PLACARD 1 Toute sécheuse installée dans...

Page 12: ...e coffret 28 25 71 76 Aux boutons clairs 28 75 73 03 À la poignée claire de porte 29 5 74 93 À l espace libre ouvrez la porte 53 134 62 13 5 34 29 27 68 58 Alimentation électrique sur l arrière de l unité 2 375 6 03 Pipe d offre de gaz sur l arrière de l unité 72 00 172 88 38 25 97 16 41 00 97 16 Ligne taille centrale pour arrière droit parti passage 4 375 11 12 Echappements Latéraux 15 8 4 13 25 ...

Page 13: ...ations ur les exigences de ventilation 6 L installation DOIT respecter la norme fédérale sur la construction etlasécuritédesmaisonsmobilesenvigueur ManufacturedHome Construction Safety Standard partie intégrante du règlement fédéral 24 CFR Partie 32 80 ou lorsque cette norme ne s applique pas elle doit respecter la norme nationale américaine pour les maisons mobiles American National Standard for ...

Page 14: ...etirez les deux vis de fixation de charnière le bouchon carré les deux bouchons ronds et la gâche en métal de la contre porte 8 Faites une rotation de la charnière et fixez la du côté opposé de la contre porte 9 Jetez la vielle gâche en métal et posez la nouvelle gâche comprise dans la trousse de documentation sur le côté opposé de la contre porte Reposez les bouchons ronds et le bouchon carré dan...

Page 15: ...iser de cordon de rallonge avec cette sécheuse Certains cordons de rallonge ne sont pas conçus pour supporter l intensité du courant qu utilise cette sécheuse ils peuvent fondre et présenter un risque choc électrique ou d incendie Placer la sécheuse à portée de la prise murale afin de déterminer la longueur du cordon à acheter et prévoir un certain jeu dans la longueur du cordon Se reporter à la s...

Page 16: ...euse pour la facilité d utilisation Le manque d utiliser des accessoires certifiés par le fabricant a pu avoir comme conséquence des blessures des dommages matériels ou des dommages à la sécheuse Si vous désirez des pièces de remplacement pour votre machine à laver communiquez avec le numéro sans frais de Service et pièces de Frigidaire CompanyAuthorizedPartsDistributor 1 800 944 9044 ouvisiteznot...