background image

IMPORTANT SAFETY NOTICE
The information provided herein is
designed to assist qualified repair
personnel only. Untrained persons
should not attempt to make repairs
due to the possibility of electrical
shock. Disconnect power cord
before servicing.

216901200
SERVICE DATA SHEET
CHEST FREEZER

INSTALLATION
This product is designed for “free standing installation only” and three
inches of clearance must be provided on all sides of the freezer for air
circulation.

The floor or mounting surface should be level and capable of supporting the
weight of the freezer when it is fully loaded.

REFRIGERANT CHARGE AND ELECTRICAL SPECIFICATIONS
Refer to serial plate.

TEMPERATURE CONTROL
14.0°F cut in, 0°F cut-out @ number 1 setting.

PERFORMANCE (Control at number 1 setting)

Room Ambient

70°F

90°F

Freezer Compartment Temperature

5 to 12°F

5 to 12°F

Percent Running Time

30-40%

45-55%

*Wattage Range (Last 

1

of cycle)

100-140

110-145

Suction Pressure (Cut-in, cut-out), PSIG

15-0

15-0

High Side Pressure (Last 

1

3

of cycle), PSIG

105-125

155-165

Specifications subject to change without notice.
*For complete performance data by model refer to service manual.

PD642

IMPORTANT

If any green grounding
wires are removed dur-
ing servicing, they
must be returned to
their original position
and properly secured.

Thermistor

N

ELECTRICAL CIRCUIT

L

See Diagram

VR/Cold Control

White

Black

Compressor

Red

Gray

Blue

Power

Purple

User
Interface

Electronic
Module

Yellow

Blue

Brown

Orange

Lid Switch

Interior Light

Black

Red

White

Black

White

EC106

Run

Capacitor

Compressor

Controller

Yel

Wh

C10

Drier

Condenser

Outlet

Charge

Tube

Heat

Exchanger

Discharge

SP27

SYSTEM SCHEMATIC

WIRING DIAGRAM

Reviews: