IMPORTANT SAFETY NOTICE
The information provided herein is
designed to assist qualified repair
personnel only. Untrained persons
should not attempt to make repairs
due to the possibility of electrical
shock. Disconnect power cord
before servicing.
216901200
SERVICE DATA SHEET
CHEST FREEZER
INSTALLATION
This product is designed for “free standing installation only” and three
inches of clearance must be provided on all sides of the freezer for air
circulation.
The floor or mounting surface should be level and capable of supporting the
weight of the freezer when it is fully loaded.
REFRIGERANT CHARGE AND ELECTRICAL SPECIFICATIONS
Refer to serial plate.
TEMPERATURE CONTROL
14.0°F cut in, 0°F cut-out @ number 1 setting.
PERFORMANCE (Control at number 1 setting)
Room Ambient
70°F
90°F
Freezer Compartment Temperature
5 to 12°F
5 to 12°F
Percent Running Time
30-40%
45-55%
*Wattage Range (Last
1
⁄
3
of cycle)
100-140
110-145
Suction Pressure (Cut-in, cut-out), PSIG
15-0
15-0
High Side Pressure (Last
1
⁄
3
of cycle), PSIG
105-125
155-165
Specifications subject to change without notice.
*For complete performance data by model refer to service manual.
PD642
IMPORTANT
If any green grounding
wires are removed dur-
ing servicing, they
must be returned to
their original position
and properly secured.
Thermistor
N
ELECTRICAL CIRCUIT
L
See Diagram
VR/Cold Control
White
Black
Compressor
Red
Gray
Blue
Power
Purple
User
Interface
Electronic
Module
Yellow
Blue
Brown
Orange
Lid Switch
Interior Light
Black
Red
White
Black
White
EC106
Run
Capacitor
Compressor
Controller
Yel
Wh
C10
Drier
Condenser
Outlet
Charge
Tube
Heat
Exchanger
Discharge
SP27
SYSTEM SCHEMATIC
WIRING DIAGRAM