background image

5

30" ELECTRIC SLIDE-IN RANGE INSTALLATION INSTRUCTIONS

6.

  The metal flange under each side of the cooktop 

MUST

 be placed 

over the cabinet countertop for proper unit support. The cooktop 
should 

NOT

 rest directly on the countertop (see illustration 2) or else 

it could cause damage to the cooktop voiding the warranty. Level the 
unit if needed.

7.

  After the installation, 

MAKE SURE that the 
unit is supported by 
the leveling legs and 
NOT by the cooktop.

1.

  The counter-top around the cut-out should be flat and leveled (see 

hatched area on illustration 1)

H1

H2

H3

H4

Illustration 1

Shave 
Raised
Edge to
Clear Space 
for a 31½" 
(80 cm) Wide

 

Cooktop.

1 ½" Max.

(3.8 cm Max.)

Illustration 2

To successfully 
install the range, 
the initial level 

height from floor 

to underside of 
cooktop frame 
should be at 
least 1/16" (0,16 
cm) taller than 
cabinet sides 
as measured in 
step 2.

To avoid breakage: Do NOT handle or manipulate 

the unit by the cooktop.

2.

  Before installing the unit, 

measure the heights of 
the two (2) cabinet sides 
(H1-4), front and back 
(see illustration 1) from 

the floor to the top of the 

counter.

3.

  Level the range using the leveling legs and leveling 

device (if equipped) so that the height from the 

floor to the underside of the cooktop glass frame is 

greater than the tallest cabinet measurement by at 
least 1/16" (0,16 cm) (see illustration 2).

4.

  Slide the unit into the cabinet. Make sure the center of the unit is aligned with the center of 

the cabinet cut-out.

5.

  Remove the protective channels on each side of the cooktop (if provided).

Metal
Flange

Summary of Contents for CGES3065PW

Page 1: ...t Notes to the Installer 1 Read all instructions contained in these installation instructions before installing range 2 Remove all packing material from the oven and the drawer compartments before connecting the electrical supply to the range 3 Observe all governing codes and ordinances 4 Be sure to leave these instructions with the consumer Important Note to the Consumer Keep these instructions w...

Page 2: ...es and with CAN CSA Z240 MH in Canada Make sure the wall coverings around the range can withstand the heat generated by the range Before installing the range in an area covered with linoleum or any other synthetic floor covering make sure the floor covering can withstand heat at least 90 F 32 2 C above room temperature without shrinking warping or discoloring Do not install the range over carpetin...

Page 3: ...o the side cabinets 3 24 61 cm minimum clearance between the cooktop and the bottom of the overhead cabinet when the bottom of wood or metal cabinet is protected by not less than 0 64 cm flame retardant millboard covered with not less than No 28 MSG sheet metal 0 015 0 4 mm stainless steel 0 024 0 6 mm aluminum or 0 020 0 5 mm copper 30 76 2 cm minimum clearance when the cabinet is unprotected 4 F...

Page 4: ...ch the cutout width IMPORTANT To avoid cooktop breakage for cutout width E dimension of more than 30 1 16 76 4 cm make sure the appliance is centered in the counter opening while pushing into it Raise leveling legs and the rear adjustable wheels at a higher position than the cabinet height see page 5 insert the appliance in the counter and then level Make sure the unit is supported by the leveling...

Page 5: ...ion 2 To successfully install the range the initial level height from floor to underside of cooktop frame should be at least 1 16 0 16 cm taller than cabinet sides as measured in step 2 To avoid breakage Do NOT handle or manipulate the unit by the cooktop 2 Before installing the unit measure the heights of the two 2 cabinet sides H1 4 front and back see illustration 1 from the floor to the top of ...

Page 6: ...ounding Strap U S A Electrical Shock Hazard Electrical ground is required on this appliance Do not connect to the electrical supply until appliance is permanently grounded Disconnect power to the circuit breaker or fuse box before making the electrical connection This appliance must be connected to a grounded metallic permanent wiring system or a grounding connector should be connected to the grou...

Page 7: ...s Location Black Wire Terminal Block Cord Mounting Plate Neutral White Wire Grounding Strap Red Wire DO NOT loosen the screws that attach the terminal block to the appliance 3 Using the nuts supplied with the literature package connect the ground wire green of the copper power supply cord to the frame of the appliance with the ground screw using the hole in the frame where the ground strap was rem...

Page 8: ...s of countertop opening 1 Be sure that no power is supplied on the cable from residence 2 DO NOT remove the grounding strap for 3 wire installation 3 In the circuit breaker fuse box or junction box a Connect the green or bare copper wire the white appliance cable wire and the neutral white wire together b Connect the 2 black wires together c Connect the 2 red wires together Where local codes DO NO...

Page 9: ...sitting level on the countertop Refer to Levelling the Range section 7 After installation verify that the anti tip bracket is engaged by grasping the top rear edge of the range and carefully attempt to tilt it forward to make sure range is properly anchored 7 Anti Tip Brackets Installation 7 1 Models Equipped with Leveling Device To reduce the risk of tipping of the range the range must be secured...

Page 10: ...ge if necessary by adjusting the leveling legs Leg Leveler Raise Lower Range side FASTEN BRACKET WALL OR FLOOR MOUNTING Leveling leg Wall mount Floor Mount Anti Tip Bracket Rear of Range Wall Plate 7 2 Models Equipped with Leveling Legs To reduce the risk of tipping of the range the range must be secured to the floor by the properly installed anti tip bracket and screws packed with the range Failu...

Page 11: ...evel Follow the instructions under Leveling the Range Models Equipped with Leveling Device 8 13 On models with a leveling device remove the rear legs and discard Adjust the leveling legs on the front of the appliance so that the cooktop glass clears the countertop Level the appliance see Leveling the range Models Equipped with Leveling Device The glass should not be supported by the countertop or ...

Page 12: ...e is level by installing an oven rack in the center of the oven and placing a level on the rack Figure 17 4 Take 2 readings with the level placed diagonally in one direction and then the other Level the range if necessary by adjusting the leveling legs and wheels 5 If the range cannot be level contact a carpenter to correct sagging or sloping floor 9 2 Models Equipped with Leveling Legs Level the ...

Page 13: ... the convection fan turns The convection fan will stop turning when the oven door is opened during convection baking or roasting Warmer Drawer some models Set the control to HI and check to see the drawer is heating When Power Connection is Completed Make sure all controls are left in the OFF position Model and Serial Number Location The serial plate is located on the oven front frame behind the o...