30" ELECTRIC SLIDE-IN RANGE INSTALLATION INSTRUCTIONS

Four Conductor Wire Connection to Range

Where local codes DO NOT permit connection of the 
frame grounding conductor to the neutral wire of the 
copper power supply cord (see Figure 4):

1.  Remove the screw holding the rear wire cover, 

then remove the rear wire cover (access cover) 
to expose range terminal connection block (see 
Figure 2).

2.  Remove the grounding strap. Remove the screw 

that holds the strap against the appliance. Cut the 
strap off at the terminal block, or bend the strap 
back and forth to break it from the terminal block. 

5.

 Electrical Connection to the 

Range (U.S.A.)

Three Conductor Wire Connection to 

Range

If local codes permit connection of the frame grounding 
conductor to the neutral wire of the copper power 
supply cord (see Figure 3):

1.  Remove the screw holding the rear wire cover, 

then remove the rear wire cover (access cover) 
to expose range terminal connection block (see 
Figure 2).

2.  Using the nuts supplied in the literature package, 

connect the neutral of the copper power supply 
cord to the center silver-colored terminal of the 
terminal block, and connect the other wires to the 
outer terminals. Match wires and terminals by color 
(red wires connected to the right terminal, black 

wires connected to the left terminal) (see figure 3).

3.  Put back the rear wire cover using the screw 

removed on step 1.

Figure 3

Silver Colored Terminal

1 1/8" (2,9 cm) Dia. 

Direct Connection 

Hole. Punch Out 

Knockout for 1 3/8" 

(3,5 cm) Dia. Cord 

Kit Hole.

To 240 V 
Receptacle

A User Supplied 
Strain-relief Must 
Be Installed at This 
Location.

Black 
Wire

Terminal
Block

Cord 

Mounting 

Plate

Neutral 

(White Wire)

Grounding
Strap

Red Wire

DO NOT loosen the screws that attach the terminal 
block to the appliance.

3.  Using the nuts supplied with the literature package, 

connect the ground wire (green) of the copper 
power supply cord to the frame of the appliance with 
the ground screw, using the hole in the frame where 
the ground strap was removed (see Figure 4).

4.  Connect the neutral of the copper power supply 

cord to the center silver-colored terminal of the 
terminal block, and connect the other wires to the 
outer terminals. Match wires and terminals by color 
(red wires connected to the right terminal, black 
wires connected to the left terminal).

5.  Put back the rear wire cover using the screw 

removed on step 1.

Direct Electrical Connection to the Circuit 

Breaker, Fuse Box or Junction Box

 Disconnect power to the circuit breaker 

or fuse box before making the electrical connection.

If the appliance is connected directly to the circuit 

breaker, fuse box or junction box, use flexible, armored 

or nonmetallic sheathed copper cable (with grounding 
wire). Supply a U.L. listed strain-relief at each end of 
the cable. At the appliance end, the cable goes through 
the Direct Connection Hole (see Figure 4) on the Cord 
Mounting Plate. Wire sizes 

(copper wire only)

 and 

connections must conform to the rating of the appliance.

Where local codes permit connecting the 

appliance-grounding conductor to the neutral 

(white) wire (see Figure 5):

Terminal Block

Silver Colored Terminal 

Red
Wire

Neutral 
(White Wire)

Ground (Bare 
Copper Wire)

To 240 V 
Receptacle

A User Supplied 
Strain-relief Must 
Be Installed at 
This Location

Black Wire

1 1/8" (2,9 
cm) Dia. 
Direct 
Connection 
Hole. Punch 
Out Knockout 
for 1 3/8" (3,5 
cm) Dia. Cord 
Kit Hole.

Figure 4

Summary of Contents for CGES3065PW

Page 1: ...t Notes to the Installer 1 Read all instructions contained in these installation instructions before installing range 2 Remove all packing material from the oven and the drawer compartments before connecting the electrical supply to the range 3 Observe all governing codes and ordinances 4 Be sure to leave these instructions with the consumer Important Note to the Consumer Keep these instructions w...

Page 2: ...es and with CAN CSA Z240 MH in Canada Make sure the wall coverings around the range can withstand the heat generated by the range Before installing the range in an area covered with linoleum or any other synthetic floor covering make sure the floor covering can withstand heat at least 90 F 32 2 C above room temperature without shrinking warping or discoloring Do not install the range over carpetin...

Page 3: ...o the side cabinets 3 24 61 cm minimum clearance between the cooktop and the bottom of the overhead cabinet when the bottom of wood or metal cabinet is protected by not less than 0 64 cm flame retardant millboard covered with not less than No 28 MSG sheet metal 0 015 0 4 mm stainless steel 0 024 0 6 mm aluminum or 0 020 0 5 mm copper 30 76 2 cm minimum clearance when the cabinet is unprotected 4 F...

Page 4: ...ch the cutout width IMPORTANT To avoid cooktop breakage for cutout width E dimension of more than 30 1 16 76 4 cm make sure the appliance is centered in the counter opening while pushing into it Raise leveling legs and the rear adjustable wheels at a higher position than the cabinet height see page 5 insert the appliance in the counter and then level Make sure the unit is supported by the leveling...

Page 5: ...ion 2 To successfully install the range the initial level height from floor to underside of cooktop frame should be at least 1 16 0 16 cm taller than cabinet sides as measured in step 2 To avoid breakage Do NOT handle or manipulate the unit by the cooktop 2 Before installing the unit measure the heights of the two 2 cabinet sides H1 4 front and back see illustration 1 from the floor to the top of ...

Page 6: ...ounding Strap U S A Electrical Shock Hazard Electrical ground is required on this appliance Do not connect to the electrical supply until appliance is permanently grounded Disconnect power to the circuit breaker or fuse box before making the electrical connection This appliance must be connected to a grounded metallic permanent wiring system or a grounding connector should be connected to the grou...

Page 7: ...s Location Black Wire Terminal Block Cord Mounting Plate Neutral White Wire Grounding Strap Red Wire DO NOT loosen the screws that attach the terminal block to the appliance 3 Using the nuts supplied with the literature package connect the ground wire green of the copper power supply cord to the frame of the appliance with the ground screw using the hole in the frame where the ground strap was rem...

Page 8: ...s of countertop opening 1 Be sure that no power is supplied on the cable from residence 2 DO NOT remove the grounding strap for 3 wire installation 3 In the circuit breaker fuse box or junction box a Connect the green or bare copper wire the white appliance cable wire and the neutral white wire together b Connect the 2 black wires together c Connect the 2 red wires together Where local codes DO NO...

Page 9: ...sitting level on the countertop Refer to Levelling the Range section 7 After installation verify that the anti tip bracket is engaged by grasping the top rear edge of the range and carefully attempt to tilt it forward to make sure range is properly anchored 7 Anti Tip Brackets Installation 7 1 Models Equipped with Leveling Device To reduce the risk of tipping of the range the range must be secured...

Page 10: ...ge if necessary by adjusting the leveling legs Leg Leveler Raise Lower Range side FASTEN BRACKET WALL OR FLOOR MOUNTING Leveling leg Wall mount Floor Mount Anti Tip Bracket Rear of Range Wall Plate 7 2 Models Equipped with Leveling Legs To reduce the risk of tipping of the range the range must be secured to the floor by the properly installed anti tip bracket and screws packed with the range Failu...

Page 11: ...evel Follow the instructions under Leveling the Range Models Equipped with Leveling Device 8 13 On models with a leveling device remove the rear legs and discard Adjust the leveling legs on the front of the appliance so that the cooktop glass clears the countertop Level the appliance see Leveling the range Models Equipped with Leveling Device The glass should not be supported by the countertop or ...

Page 12: ...e is level by installing an oven rack in the center of the oven and placing a level on the rack Figure 17 4 Take 2 readings with the level placed diagonally in one direction and then the other Level the range if necessary by adjusting the leveling legs and wheels 5 If the range cannot be level contact a carpenter to correct sagging or sloping floor 9 2 Models Equipped with Leveling Legs Level the ...

Page 13: ... the convection fan turns The convection fan will stop turning when the oven door is opened during convection baking or roasting Warmer Drawer some models Set the control to HI and check to see the drawer is heating When Power Connection is Completed Make sure all controls are left in the OFF position Model and Serial Number Location The serial plate is located on the oven front frame behind the o...

Reviews: