background image

30" DUAL FUEL SLIDE-IN RANGE INSTALLATION INSTRUCTIONS

(Models with an Electric Oven and a Gas Cooktop)

1

P/N 318201690 (1302) Rev. B

English – pages 1-13

Español – páginas 14-26

Français – pages 27-39

Wiring Diagrams - pages 40

 If the information in this manual is not followed exactly, a fire 

or explosion may result causing property damage, personal injury or death.
FOR YOUR SAFETY:
—  Do not store or use gasoline or other flammable vapors and liquids in 

the vicinity of this or any other appliance.

—  WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor's phone.  Follow the
gas supplier's instructions.

If you cannot reach your gas supplier, call the fire department.

—  Installation and service must be performed by a qualified installer, 

service agency or the gas supplier.

INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER.

IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE.

READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.

NOTE: Wiring diagram for these appliances are enclosed in this booklet.

Printed in Canada

Refer to your serial plate for 

applicable agency certification

1/2” min.

1/4” min.

WALL

5" Min.

(12.7 cm Min.)

From Wall Both Sides

30" Min.

(76.2 cm Min.)

30" Min. (76.2 cm) 

Min. (see Note 3)

18" Min.

(45.7 cm) Min.

Approx. 1 7/8"

(4.8 cm)

Grounded Jonction Box or Wall Outlet Should Be 

Located 8" to 17" (20.3 cm to 43.2 cm) From Right 

Cabinet and 2" to 4" (5.1 cm to 10.2 cm) From Floor.

Locate Cabinet Doors 

1" (2.5 cm) Min. from 

Cutout Opening.

F

G

E

31 1/2" 

(81 cm) 

Exact

13"

(33 cm)

24" Min.

(61 cm Min.)

Shave
Raised
Edge
to Clear
Space
for a 31½"
(81 cm) Wide
Cooktop.

1 ½" Max.

(3.8 cm Max.)

These surfaces  

should be 

flat & leveled 

(hatched area). 

Do not install the unit in the cabinet before reading next page.

A

. HEIGHT

(Under Cooktop)

B

WIDTH

C.

 COOKTOP 

WIDTH

D

TOTAL DEPTH TO 

FRONT OF RANGE

E

CUTOUT WIDTH***

(Countertop

and cabinet)

F

CUTOUT

DEPTH

G

HEIGHT

 OF COUNTERTOP

35 7/8" (91,1 cm)

36 5/8" (93 cm)

30" (76,2 cm) 

31 1/2"

(80 cm)

28 5/16" (71,9 cm) 

30±1/16"

(76,2±0,15 cm) 

21 3/4" (55,2 cm) Min.

22 1/8" (56,2 cm) Max

24" (61 cm) Min. with 

backguard

35 7/8" (91,1 cm) Min.

36 5/8" (93 cm) Max. 

Appliances Installed in the 
state of Massachusetts:

This Appliance can only 

be installed in the state of 

Massachusetts by a Massachusetts 
licensed plumber or gasfitter.
This appliance must be installed 

with a three (3) foot / 36 in. long 
flexible gas connector.
A"T" handle type manual gas 

valve must be installed in the gas 

supply line to this appliance.

Summary of Contents for CPDS3085KF

Page 1: ...a Refer to your serial plate for applicable agency certification 1 2 min 1 4 min WALL 5 Min 12 7 cm Min From Wall Both Sides 30 Min 76 2 cm Min 30 Min 76 2 cm Min see Note 3 18 Min 45 7 cm Min Approx 1 7 8 4 8 cm Grounded Jonction Box or Wall Outlet Should Be Located 8 to 17 20 3 cm to 43 2 cm From Right Cabinet and 2 to 4 5 1 cm to 10 2 cm From Floor Locate Cabinet Doors 1 2 5 cm Min from Cutout ...

Page 2: ...pth when it is open 21 55 25 cm D C A B Door Open Side Panel 1 1 8 2 86 cm FRONT OF CABINET FRef 22 7 8 58 1 cm min 23 1 4 59 05 cm max see Note 4 IMPORTANT To avoid cooktop breakage for cutout width E dimension of more than 30 1 16 76 4 cm make sure the appliance is centered in the counter opening while pushing into it Raise leveling legs at a higher position than the cabinet height see page 3 in...

Page 3: ...oktop Illustration 2 To successfully install the range the initial level height from floor to underside of cooktop frame should be at least 1 16 taller than cabinet sides as measured in step 2 Level the range using the four 4 leveling legs so that the height from the floor to the underside of the metal flange is greater than the tallest cabinet measurement by Metal Flange at least 1 16 see illustr...

Page 4: ...le Home Construction and Safety title 24 HUD part 280 or when such standard is not applicable the Standard for Manufactured Home Installation 1982 Manufactured Home Sites Communities and Setups ANSI Z225 1 NFPA 501A latest edition or with local codes in United States and with CAN CSA Z240 MH in Canada Make sure the wall coverings around the range can withstand the heat generated by the range Befor...

Page 5: ...is permanently grounded Disconnect power to the circuit breaker or fuse box before making the electrical connection This appliance must be connected to a grounded metallic permanent wiring system or a grounding connector should be connected to the grounding terminal or wire lead on the appliance Failure to do any of the above could result in a fire personal injury or electrical shock 1 Factory Con...

Page 6: ...ral White Wire Ground Bare Copper Wire To 240 V Receptacle A User Supplied Strain relief Must Be Installed at This Location Black Wire 1 1 8 2 9cm Dia Direct Connection Hole Punch Out Knockout for 1 3 8 3 5cm Dia Cord Kit Hole NOTE Be sure to remove the supplied grounding strap Figure 4 4 Electrical Connection to the Range U S A Three Conductor Wire Connection to Range If local codes permit connec...

Page 7: ...Connect the 2 black wires together c Connect the 2 red wires together Figure 5 3 Wire Grounded Neutral Electrical System Example Junction Box Cable from Residence Junction Box White Wire U L listed Conduit Connector or CSA listed Cable from Appliance Green or Bare Copper Wire Red Wires Neutral white Wire Black Wires NOTE Be sure to remove the supplied grounding strap Where local codes DO NOT permi...

Page 8: ...re the inlet pressure must be at least 5 12 60 cm water column 1 25 kPa Natural gas For LP Propane gas the regulator must be set for 10 25 4 cm water column 2 5 kPa manifold pressure the inlet pressure must be at least 11 27 9 cm water column 2 75 kPa The supply line should be equipped with an approved shutoff valve see Figure 10 This valve should be located in the same room as the range and shoul...

Page 9: ...ne Leak testing of the appliance shall be conducted according to the manufacturer s instructions Check for leaks After connecting the range to the gas supply check the system for leaks with a manometer If a manometer is not available turn on the gas supply and use a liquid leak detector at all joints and connections to check for leaks Do not use a flame to check for leaks from gas connections Chec...

Page 10: ...n on page 1 9 5 Make sure the four leveling legs are setup higher than the height of the cabinet shown on page 3 9 6 Install the anti tip bracket at this point before placing the range at its final position Follow the installation instructions on page 13 or on the anti tip bracket template supplied with the range 9 7 To provide an optimum installation the top surface of the countertop must be leve...

Page 11: ... for each burner Try each knob separately until all burner valves have been checked 11 4 Adjust the LOW Setting of Surface Burner Valves see Figure 13 a Push in and turn each control to LITE until burner ignites b Quickly turn knob to LOWEST POSITION c If burner goes out readjust valve as follows Reset control to OFF Remove the surface burner control knob insert a thin bladed screw driver into the...

Page 12: ...ide for phone number and address Please call or write if you have inquiries about your range product and or need to order parts Serial Plate Location 11 6 Operation of Oven Elements The oven is equipped with an electronic oven control Each of the functions has been factory checked before shipping However it is suggested that you verify the operation of the electronic oven controls once more Refer ...

Page 13: ... You may also grasp the top rear edge of the range and carefully attempt to tilt it forward to make sure range is properly anchored Figure 16 Leveling Leg Raise Lower CL 18 46 4 cm 28 1 8 71 4 cm 9 1 8 23 2 cm 12 Anti Tip Brackets Installation Instructions To reduce the risk of tipping of the range the range must be secured to the floor by properly installed anti tip brackets and screws packed wit...

Page 14: ...40 INSTRUCTIONS D INSTALLATION POUR CUISINIÈRE ENCASTRABLE DE 30 À ALIMENTATION MIXTE Modèles avec four électrique et plaque de cuisson à gaz WIRING DIAGRAM Diagrama de cables SCHÉMA DE CÂBLAGE ...

Reviews: