Section 3 Electronic Control Testing
3-6
Reading Error Codes - Affinity Models
1. Press and hold the SELECT and CANCEL buttons simultaneously for 6 seconds to reset control. The buzzer will
sound 1 time and “rES” will be shown briefly in the display.
2. Immediately after, rotate cycle selector knob 2 turns counter-clockwise to the third position from the top, and
then press and hold the SELECT and CANCEL buttons simultaneously for 6 seconds. The control will enter Field
Test Mode, the buzzer will sound 3 times, and the digital display will alternate between “Fld” and the firmware
revision number (ex. “r03”).
3. Rotate the cycle selector knob 2 turns counterclockwise. The error code will appear in the digit display.
Troubleshoot problem by using chart on next page.
To move on to the next code, press the OPTIONS button.
To clear code, press the SELECT button. Code will be cleared when mode is exited.
To exit this mode, simultaneously press and hold the SELECT and CANCEL buttons for 6 seconds.
Function Test Sequence
1. Press and hold SELECT and CANCEL buttons simultaneously for 6 seconds to reset the control. The buzzer will
sound and “rES” will be shown briefly in the display.
2. Immediately after, rotate cycle selector knob 5 turns counter-clockwise to the second position from the bottom.
Press and hold the OPTIONS and CANCEL buttons simultaneously for 2 seconds. The control will enter test mode,
the buzzer will sound 3 times and all LED’s will rapidly flash.
After entering the test mode, the cycle selector knob can now be rotated to select the following tests:
Rotate the cycle selector knob clockwise from the starting position:
0 turns:
All LED’s will flash.
1 turn:
Drive motor runs; heat source is on. Drying LED is lit. “H” and the control thermistor reading will toggle
back and forth in the display.
2 turns:
Drive motor runs; heat source is off. Cool Down LED is lit and “AF” (Air Fluff) is displayed.
3 turns:
Drive motor runs; heat source is off. Drying and Cool Down LED’s are lit and numbers appear in the
display showing moisture sensor readings. Opening the door (press in on door switch plunger) and
placing a finger on the both moisture sense bars at the same time will make the numbers decrease. In
controls that do not have a digit display, the More Dry LED should be ON. Opening the door (press in on
door switch plunger) and placing a finger on the both moisture sense bars at the same time will make the
Damp LED come on.
4 turns:
Drive motor runs; heat source is off.
Key
test:
a. When the TEMPERATURE key is pressed, all the temperature LED’s should light.
b. When the DRYNESS key is pressed, all the dryness level LED’s should light.
c. When the OPTIONS or SELECT key is pressed, all the Option LED’s should light.
d. When the START/PAUSE key is pressed, all the cycle status LED’s should light.
e. When the CANCEL key is pressed, all the cycle status LED’s should light.
5 turns:
Drive motor runs; heat source is off. Cool Down LED is lit. Control thermistor reading is displayed.
6 turns:
Drive motor runs; heat source is on. Drying LED is lit. Control thermistor reading is displayed.
7-11 turns: All LED’s will flash
To EXIT test mode, press and hold the SELECT and CANCEL buttons simultaneously for 6 seconds or disconnect
power from dryer. Dryer will be reset for regular operation.
Section 3 Electronic Control Affinity Series
Summary of Contents for Designer Series
Page 2: ......
Page 87: ...Section 6 Wiring Diagrams 6 1 Affinity Series With Electric Heater ...
Page 88: ...Section 6 Wiring Diagrams 6 2 Affinity Series With Gas Heater ...
Page 89: ...Section 6 Wiring Diagrams 6 3 Gallery Series With Electric Heater ...
Page 90: ...Section 6 Wiring Diagrams 6 4 Gallery Series With Gas Heater ...