Section 3 Electronic Control Testing
3-24
Drive motor runs but
drum does not turn.
Electric and Gas dryers; blower motor runs but drum does not turn.
Note: Always check wiring to the components.
Belt broken or
off pulley.
Longer than normal
drying times.
Electric and Gas dryers; longer than normal drying times. (Possible E 4A)
Note: Always check wiring to the components.
Check washer
spin cycle.
Are the clothes wetter than normal
when removed from the washer?
Yes.
Clear vent.
Is the vent restricted?
Yes.
No.
No.
Refer to dryer not
heating properly
flow chart.
Is the dryer heating properly?
Review proper
programming of
the control with
the customer.
Yes.
Is the dryer level so the clothes
touch the sensor bars?
Yes.
Level dryer.
No.
Is the blower motor running
at full speed?
No.
Yes.
Replace motor.
No.