OPERATION

Ambient temperature

Temperature 0-35°C

Atmosphere 86-106 kpa

VOLTAGE:115V/60HZ

Position the water cooler on the horizontal, structurally sound ground. Leave an

adequate open space (10-20 cm) behind the water cooler for good ventilation.

When using the bottles holding ultra-pure water, distilled water or space water with

the so-called clever lid, tear off the hygienic labels on the lid.Place the bottles at the

intake, then the core of water guard will automatically open the valve and seal it in

the meantime, when moving the bottles, the valve will also seal automatically to

avoid any possible oozing.

Push the hot water valves, bubbles are generated inside the bottle, indicating

that water is flowing into hot water and cold water tanks,keep pressing the hot water

valve until water flows out,dispensing cold water required need no particular

adjustment.

Caution: Do no connect the electrical power plug,until water comes out of the hot

water tap.

After water is flowing out from the hot tap; power can be on, the yellow LED indicator

on the front light on.

Turn the heating switch on, the red LED indicator on the front lights on and the

heating system starts working, when the hot water comes up (86-95°C) or so, the

red light goes off, the heating system stops working is on a warm keeping status.

When the hot water temperature is lower than 85°C, the heating system will resume

working again automatically.

Turn on the cooling switch, the green LED indicator on the front lights on and the

cooling system starts working when the cold water falls down to 5-15°C (for

compressor-cooling)

the green light goes off, the cooling system stops working

and is on a cold keeping status.When the cold water temperature goes up to a set

degree, the cooling system will resume working again atomically.

Since the temperature has already been adjusted before leaving the factory, it is

unnecessary for customer to set the temperature.

Turn the heating, cooling water switch on.Then the heating and cooling processes

start working, the heating indicator is red showing it is heating. When the hot water

temperature reaches the set limit, the heating process starts working automatically.

When cooling is lit green, the cold water starts working. The cooling indicator goes

out as the temperature of the cold water and fridge get the set lower limit. The

cooling process stops working,when the cold water temperature gets the set upper

Summary of Contents for EFWC498

Page 1: ...R DISPENSER Model Number EFWC498 BEFORE USE PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS Frigidaire is a pending or registered trademark used under license from Electrolux Home Products Inc Made in China ...

Page 2: ...NAME AND STRUCTURE 1 Power ON OFF switches at rear 2 Water Bottle Inlet 3 Hot Water Button 4 Cold Water Button 5 Indicator Lights 6 Hot Water Faucet 7 Cold Water Faucet 8 Water Drip Tray ...

Page 3: ...icator on the front lights on and the heating system starts working when the hot water comes up 86 95 C or so the red light goes off the heating system stops working is on a warm keeping status When the hot water temperature is lower than 85 C the heating system will resume working again automatically Turn on the cooling switch the green LED indicator on the front lights on and the cooling system ...

Page 4: ...ack of the device should be kept away from wall and high temperature elements TV or video valuables and be put in shady places Donot switchon untilwater comes out of the hot water valve to prevent any damage on the heating tube During operation keeping it beyond the children to avoid scald Never turn on the heating switch when there is no water When carrying it the angle of inclination should be l...

Page 5: ... decrease Fill hot water tank with aqueous solution of 2 iatric acid and keep for about two hours then cleaning If the problems can not be solved contact your dealer or the service centre of our company If the supply cord on this device is damaged It must be replace with a special cord switch is obtainable at the service centre of our company TROUBLESHOOTING GUIDE Problem Possible cause Water cool...

Page 6: ...ay come from flow of the refrigerant which is normal As each cycles ends you may hear gurgling Sound cause by the flow of refrigerant in your water cooler Contraction and expansion of inside walls may cause popping and cracking noises The water cooler is not level ...

Page 7: ...WIRING DIAGRAM 86 ...

Page 8: ... Modèle EFWC498 AVANT UTILISATION VEUILLEZ LIRE ET RESPECTER TOUTES LES REGLES DE SECURITE ET INSTRUCTIONS D UTILISATION Frigidaire est une marque commerciale en attente ou enregistrée utilisée sous licence par Electrolux Home Products Inc Fabriqué en Chine ...

Page 9: ...Le nom et la structure 1 Interupteurs 2 Bouteille d eau Inlet 3 Bouton d eau chaude 4 Bouton d eau froide 5 Voyants 6 Robinet d eau chaude 7 Robinet d eau froide 8 Bac de récupération ...

Page 10: ... devant s allume Modèle26 Modèle 30 Appuyer sur le bouton de chauffage et la lampe indicative rouge qui est devant s allume la machine commence à fonctionner Quand la température s élève à 86 95 C environ la lampe indicative rouge s éteint le chauffage s arrête et la machine passe au mode de conservation de la chaleur Quand la température de l eau est inférieure de 86 C le système de chauffage rec...

Page 11: ...vez la prise électrique et tournez le robinet de vidange pour enlever l eau dans le reservoir eau chaude resserrer alors le robinet ouvrir le robinet d eau froide pour vidanger l eau dans le réservoir eau froide S il n y a pas d eau qui s écoule du robinet de refroidissement arrêtez le commutateur de refroidissement jusqu à ce qu il y ait l eau sortant Attention Le dos du dispositif doit être éloi...

Page 12: ...ice après vente Guide de dépannage Problème Cause possible Le distributeur de l eau ne fonctionne pas Non branché Fusible débranché ou le disjoncteur a sauté Le refroidisseur de l eau n est pas assez froid Contrôler si le passage froid à l arrière est allumé Le distributeur d eau n a pas le dégagement correct L eau chaude n est pas assez chaude Contrôler si le passage chaud à l arrière est allumé ...