background image

3

FIG. 2

FIG. 5

FIG. 6

FIG. 7

CUT STRIPS TO FIT

CENTER
LINE

WIDTH OF
RANGE
HOOD

ELECTRICAL
WIRING OPENING

FIG. 3

DUCT

OPENINGS

PREPARING THE RANGE HOOD

1. Unpack hood and check contents. You should receive:

1 - Aluminum Filter
1 - 3-1/4" x 10" Damper/Duct Connector (mounted inside of
hood for shipping only) (Save screws for mounting.)
1 - 7” Round Duct Plate (mounted on top of hood) (not shown)
(Save screws for mounting.)

2. Remove 7” round duct plate from top of hood. Set duct plate

aside - with mounting screws.

3. Remove wiring box cover. Under cover find:

PREPARING THE
INSTALLATION LOCATION

FIG. 4

WIRING BOX

COVER

DAMPER/DUCT CONNECTOR

ALUMINUM
FILTER

For Ductfree Installations Only:

4. For ductfree installation, remove louver cover from front (or

inside) of hood. (FIG. 3)

NOTE

Louvers on front of hood must be open and visible

for hood to function in ductfree mode.

5. Remove either top or rear electrical knockout depending upon

whether wiring will enter hood from wall or cabinet. (FIG. 4)

DUCTED INSTALLATION ONLY

NOTE

Louver cover must be installed as shown in Figure 3 to

function in ducted mode.

6. Remove appropriate duct knockout on hood by inserting

screwdriver into edge of knockout and breaking tabs holding
knockout to hood. You may have to tap screwdriver with ham-
mer to break tabs. Peel knockout back with pliers. (FIG. 5)

7. Fit damper/duct connector over opening and secure in place with

black sheet metal screws. (FIG. 6)
Hinge pins and damper/duct connector should be toward top
of hood for ducting through wall or toward back of hood for
ducting through cabinet above hood. Seal joint between
damper/duct connector and hood with duct tape.

8.

7” round ducted discharge only:

 Re-install 7” round duct

plate removed in Step #2 under “PREPARING THE RANGE
HOOD” section. 

For best performance, line up the 7” round

duct plate with the 7” round opening on hood.

 Mount duct

plate to hood with 2 screws from duct plate and 2 screws
from 3¼” x 10” damper. Install a 7” round damper (purchase
separately). Damper flap must open freely in direction of air
flow (away from range hood).

KEYHOLE SLOTS

NOTE

MOUNT HOOD SO THAT BOTTOM OF HOOD IS 18"-24" ABOVE
COOKING SURFACE. TOP FRONT EDGE OF HOOD SHOULD
BE FLUSH WITH FRONT OF CABINET FRAME.
IF DISTANCE BETWEEN WALL AND FRONT OF CABINET
FRAME IS MORE THAN 12" THERE WILL BE A SPACE BE-
TWEEN BACK OF HOOD AND WALL. THIS IS NORMAL.

OMIT STEP 9 if range hood will be installed under cabinets
with flush bottom.

9. (For installation on recessed bottom cabinets only) Attach a

wood filler strip at each side of recessed area under cabi-
net. (Use two 1" x  2" strips cut to length.) If recess is more
than 1" use thicker strips. Attach strips with 1-1/4" screws
about 3" from each end. See FIG. 7.

10.Measure and mark the following (FIGS. 7 & 8):

a) Electrical line opening
b) Duct opening

11.Drill four pilot holes in corners of marked duct opening as

shown and cut opening with saber saw or keyhole saw.

12.Use 1-1/4" drill bit to drill opening for electrical connection

in wall or cabinet.

13.Hold hood up against cabinet bottom and trace keyhole slots

onto cabinet bottom of filler strips.

14.Screw the four supplied 7/8" wood screws for mounting the

hood into the exact center of the narrow end of the keyhole
slots marked underneath the cabinet. Allow 3/8" of the
screws to project, so the hood can be fitted into place.

Summary of Contents for F30WC Series

Page 1: ...ed to accumulate on fan or filter 4 Use proper pan size Always use cookware appropriate for the size of the surface element IMPORTANT For Non ducted Ductfree Installation a Purchase non ducted filter separately b Remove and discard damper duct connector and louver cover See Step 4 in Prepare the Hood Page 2 c Follow all steps except steps inside dotted lines For Ducted Installation Follow all step...

Page 2: ...ations a 3 1 4 rectangular ducting range hood can be converted to a round duct by means of a transition FIG 1A Ducting directly through the wall for range hoods mounted on an exterior wall Shown are two ways to duct through an outside wall If a wall cap is used directly off the back of the hood special care must be taken to make sure that the damper in the damper duct connector on the hood and dam...

Page 3: ...above hood Seal joint between damper duct connector and hood with duct tape 8 7 round ducted discharge only Re install 7 round duct plate removed in Step 2 under PREPARING THE RANGE HOOD section For best performance line up the 7 round duct plate with the 7 round opening on hood Mount duct plate to hood with 2 screws from duct plate and 2 screws from 3 x 10 damper Install a 7 round damper purchase...

Page 4: ...om so that the duct will overlap the damper duct connector by 3 4 when the hood is installed ROOF CAPS Cut hole in roof slightly larger than duct so duct will line up easily with hood Trim shingles around hole so that they will fit snugly around hood of cap when cap is installed Assemble the duct work and tape all joints Run the duct work down to hood Trim duct parallel to roof pitch leaving 3 4 o...

Page 5: ...place wiring box cover and screw Make sure that all wir ing is safely contained inside NOTE For Ductfree Installations Only Install both filters Make sure that ductfree filter purchase separately is next to fan assembly with blue side next to blade Aluminum filter should be facing out FILTER REMOVAL Filters are removed by turning filter clip to the side and lifting filter or filters out In ducted ...

Page 6: ...rately 11 Filter Retainer 12 8B x 1 4 Hex Head Sheet Metal Screws 2 Req 13 Damper Flap 14 Damper Bushing 15 Damper Assembly Includes Key Nos 13 and 14 16 Nameplate Black Nameplate White Nameplate Biscuit 17 2 Speed Motor Switch Black 2 Speed Motor Switch White 2 Speed Motor Switch Biscuit 18 Light Switch Black Light Switch White Light Switch Biscuit 19 Motor Receptacle with Wires 20 Louver Cover B...

Page 7: ...7 ...

Page 8: ...RCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED TO ONE YEAR OR THE SHORTEST PERIOD ALLOWED BY LAW BUT NOT LESS THAN ONE YEAR ELECTROLUX SHALL NOT BE LIABLE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SUCH AS PROPERTY DAMAGE AND INCIDENTAL EXPENSES RESULTING FROM ANY BREACH OF THIS WRITTEN LIMITED WARRANTY OR ANY IMPLIED WARRANTY SOME STATES AND PROVINCES DO NOT ALLOW THE EXCLUSION OR LIM...

Reviews: