background image

30" ELECTRIC RANGE INSTALLATION INSTRUCTIONS

(For 3 or 4 Wire, 60 Hz. Systems)

4

or 4B. POWER CORD CONNECTIONS
(3-Wire Connection Instructions . For existing installations ONLY
- Refer to Fig. 13).

1.

Follow the manufacturer’s installation instructions supplied with the
strain relief and install (Also see Figs. 9, 10 & 11).

2.

Insert the end connectors for Line 1, Line 2 and Neutral and tighten
securely to the terminal block (See Fig. 13).
IMPORTANT NOTE:  DO NOT LOOSEN the factory installed nut
connections which secure the range wiring to the terminal block.
Electrical failure or loss of electrical connection may occur if these 3
nuts are loosened or removed.

3.

Make sure all connections are tightened securely and replace the rear
access cover (See Fig. 9).

Grounding Instructions (3-Wire Connections only): 

A ground

strap is installed on this range which connects the center terminal of the
terminal block (Neutral) to the range chassis. The ground strap is
connected to the range by the center, lowest screw (See Fig. 13). The
ground strap must not be removed unless National, State or Local
Codes do not permit use of a ground strap.
NOTE:  If the ground strap is removed for any reason, a separate
ground wire must be connected to the separate ground screw attached
to the range chassis and to an adequate ground source.

NOTE:  Non-terminated field wire compression connections must be
set at approximately 35 in./lbs.

Fig. 13

4c. 3 & 4-WIRE PERMANENT WIRE CONNECTIONS.

3 - Wire Permanent Connection - follow Steps 1,2 & 5 below.
4 - Wire Permanent Connection - follow Steps 1 thru 5 below.
Before wiring the range, review the suggested power source location
drawings in Fig. 3. If connecting to a 4-Wire electrical system (new branch-
circuit or mobile home requires 4-Wire connection):

1.

(3 & 4 - Wire Permanent Connections) Follow the manufacturer’s
installation instructions supplied with the strain relief and install.

2.

(3 & 4 - Wire Permanent Connections) Strip insulation away from the
ends of the permanent wiring for Line 1, Line 2, Neutral (also strip ground
wire on 4-Wire Connections). Tighten all 3 wire leads to the terminal
block (Follow wire locations shown in Fig. 14).
IMPORTANT NOTE:  DO NOT LOOSEN the factory installed nut
connections which secure the range wiring to the terminal block.
Electrical failure or loss of electrical connection may occur if these 3
nuts are loosened or removed. NOTE: For 3-Wire Permanent
Connections skip Steps 3 & 4 and continue with Step 5.

3.

(4-Wire Permanent Connection ONLY) Disconnect the ground strap.
Remove the factory installed ground screw & plate to release the factory
installed copper ground strap from frame of the appliance. Cut and
discard the copper strap from the terminal block. KEEP the ground
screw, ground plate and go to Step 4.

4.

(4-Wire Permanent Connection ONLY) Connect the ground wire lead
(Green) to the frame of the appliance using the ground screw & plate as
shown in Fig. 15. Be sure to install using the same hole in the frame
where the ground screw was originally installed.

5.

(3 & 4 - Wire Permanent Connections) Make sure all connections are
tightened securely and replace the rear access cover (See Fig. 9).

Fig. 14

Fig. 15

5. CAREFULLY SLIDE RANGE INTO FINAL LOCATION.

Be sure to provide all the adequate clearances and dimensions
shown in Figs. 1, 2 & 3 before moving range into final location.

Carefully slide range into final position while inserting rear leveling leg
into and FULLY ENGAGING THE ANTI-TIP BRACKET (See Fig. 7).
Make sure the power cord folds into the remaining open floor area
behind the range Warmer or storage drawer. Be sure to check the
level of the range.

Summary of Contents for FEFS66DSG

Page 1: ... FIRE BY REACHING OVER HEATED SURFACE UNITS CABINET STORAGE SPACE LOCATED ABOVE THE SURFACE UNITS SHOULD BE AVOIDED IF CABINET STORAGE IS TO BE PROVIDED THE RISK CAN BE REDUCED BY INSTALLING A RANGE HOOD THAT PROJECTS HORIZONTALLY A MINIMUM OF 5 BEYOND THE BOTTOM OF THE CABINETS Español Páginas 5 8 IMPORTANT SAFETY INSTRUCTIONS If the information in this manual is not followed exactly a fire or el...

Page 2: ...if installing in concrete For electrical supply connection 1 4 3 8 Socket driver or Nutdriver Additional Materials You Will Need Power Supply Cord or Copper Electrical Wiring Metal Conduit for hard wiring to the wall drill pilot hole at an approximate 20 downward angle See Fig 5 If bracket is to be mounted to masonry or ceramic floors drill a 5 32 pilot hole 1 3 4 deep The screws provided may be u...

Page 3: ...E The Rear Access Cover must be removed Fig 9 To remove loosen center screw one screw and remove cover The terminal block will then be accessible Fig 10 4A POWER CORD CONNECTIONS Fig 11 Fig 12 4 Wire Connection Instructions Refer to Fig 12 Before wiring the range review the suggested power source location drawing in Fig 3 If connecting to a 4 Wire electrical system new branch circuit or mobile hom...

Page 4: ...tem new branch circuit or mobile home requires 4 Wire connection 1 3 4 Wire Permanent Connections Follow the manufacturer s installation instructions supplied with the strain relief and install 2 3 4 Wire Permanent Connections Strip insulation away from the ends of the permanent wiring for Line 1 Line 2 Neutral also strip ground wire on 4 Wire Connections Tighten all 3 wire leads to the terminal b...

Page 5: ...EINSTALANARMARIOSSOBRE LA ESTUFA SE PUEDEN REDUCIR TALES RIESGOS INSTALANDO UNA CAMPANA EXTRACTORA QUE SE PROYECTE HORIZONTALMENTE UN MINIMO DE 5 MAS AFUERA DE LA PARTE INFERIOR DE LOS ARMARIOS English Pages 1 4 TODAS LAS ESTUFAS PUEDENVOLCARSE SEPUEDENCAUSAR LESIONES INSTALE EL DISPOSITIVO ANTIVUELCOINCLUIDO CON LA ESTUFA VEALASINSTRUCCIONES DEINSTALACION Fig 1 Fig 2 Fig 3 INSTRUCCIONES IMPORTANT...

Page 6: ...ero y trate de inclinarla hacia adelantecuidadosamente 2 REQUERIMIENTOS ELECTRICOS DE CONEXION Este artefacto debe ser instalado y puesto a tierra en forma correcta por un técnico calificado de acuerdo con el Código Nacional de ElectricidadANSI NFPANo 70 últimaedición ylosrequerimientos del código local de electricidad Este artefacto debe ser conectado mediante cableado permanente o el Juego de Ca...

Page 7: ...ulg de la Abertura de Conexión de la Estufa Potencia Nominaldel Juego de cable Juego de cable Cableado Permanente 1 3 8 1 3 8 1 1 8 1 3 8 40 50 Amp 50 Amp 8 8 16 5 KW 7 9 12 5 KW 16 6 22 5 KW 12 6 18 5 KW Fig 10 Cubierta de acceso trasera Disco removible de 29mm de diám Ver Tabla Agujero de 22 mm de diám Ver Tabla Placa de montaje Agujerode 35 mm de diám Ver Tabla Cavidad para la placa de montaje ...

Page 8: ... su lugar definitivo Deslice cuidadosamente la estufa hacia la abertura del gabinete a la vez que insertaeltornilloniveladortraseroenelSOPORTEANTIVUELCOVERFICANDO QUEQUEDEBIENENGANCHADO VerFig 7 Asegúresedequeelcordónde alimentación quede plegado en el resto del área abierta del piso detrás de la gaveta de almacenamiento o gaveta calentadora de la estufa Asegúrese de verificar la nivelación de la ...

Reviews: