background image

Summary of Contents for FEZ831CFS1

Page 1: ...27 69 cm Wide LAUNDRY CENTER Washer Dryer CENTRO DE LAVANDERiA COMBINE LAVEUSE SECHUESE Largeur de 27pounces 69cm 4_1r_ PIN 134897400A 0712 ...

Page 2: ...ch as restaurants or beauty salons etc Your safety and the safety of others is very important We have provided many important safety messages in the Use Care Guide Operating Instructions Installation Instructions and on your appliance Always read and obey all safety messages This is the safety alert symbol This symbol alerts you to hazards that can kill or hurt you or others All safety messages wi...

Page 3: ...d loop connectors and marked for use with clothes dryers See ELECTRICAL CONNECTIONS Canada 4 wire power supply cord is installed on laundry center OUTLET RECEPTACLE NEMA 10 30R 3 wire receptacle or NEMA 14 30R 4 wire receptacle to be located so the power supply cord is accessiblewhen the laundry center is in an installed position NEMA 10 30R NEMA 14 30R CIRCUIT Individual 15 amp minimum branch cir...

Page 4: ...assemble the exhaust system Lint can become caught in the screen on the screwsor rivets clogging the duct work and creating afire hazard as well as increasing drying times Use an approved vent hood to terminate the duct outdoors and seal all joints with duct tape All male duct pipe fittings MUSTbe installed downstream with the flow of air Explosion hazard Do not install the dryer where gasoline or...

Page 5: ...pply connection to the dryer 6 The dryer and its individual shutoff valve MUST be disconnected from the gas supply piping system during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 45 kPa 7 The dryer MUST be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressuretesting of the gas suppl...

Page 6: ...R _ DRAIN OUTLET REAR _J I_ 3 IN 9 52 CM ii II 27 IN _ 68 58CM GAS SUPPLY PiPE REAR _ 51 41N 13 33 CM 43 IN 109 22 CM 41 4 IN 104 77 CM 29 7116 IN 74 77 CM 16 IN _ 41 27 CM LU I 25 IN 64 13 CM 47 36 1 161N 91 60 CM I L 30 13 16 IN 78 26 CM ii 14_ 2 I 2 IN I 6 35 CM 1 718 IN _ 4 76 CM 4 13 16 IN 12 22 CM 11 7 16 IN 29 5 CM ...

Page 7: ...igned under ANSI Z 21 5 1for HOME USE only iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii UNPACKING 1 Using the four shipping carton corner posts two on each side carefully lay the laundry center on its left side and remove foam shipping base Excessive weight Use two or more people to move Laundry Center 2 Using a ratchet with 3 8 inch 0 96 cm socket remove the mechanism sh...

Page 8: ...if you are in doubt as to whether the appliance is properly grounded For a qrounded cord connected laundry center 1 The laundry center MUST be grounded In the event of malfunction or breakdown grounding will reduce the risk of electrical shock by a path of least resistance for electrical current If your laundry center is equipped with a power supply cord having an equipment grounding conductor and...

Page 9: ... termial block GREEN GROUND GREEN SCREW CONDUCTOR SILVER TERMINAL TERMINAL BLOCK NEUTRAL GROUND WIRE 5 Attach the remaining two power cord outer conductors to the outer brasscolored terminals on the terminal block Tighten both screws securely 6 Tighten the screws securing the cord restraint against the power cord 7 Reinstall the terminal accesscover NEUTRAL GROUND WIRE RED _ BLACK WHITE STRAIN REL...

Page 10: ...p or down to ensure the laundry center is resting solid on all four legs no rocking of the laundry center should exist NOTE Keep the leg extension at a minimum to prevent excessive vibration Open the shutoff valve in the gas supply line Test all connections by brushing on a soapy water solution NEVER TEST FOR GAS LEAKS WITH AN OPEN FLAME Form a U shape on the end of the drain hose with the hose po...

Page 11: ... the source where you purchased your laundry centen _ Destroy the carton plastic bags and metal band after the laundry center is unpacked Children might use them for play Cartons covered with rugs bedspreads or plastic sheets can become airtight chambers causing suffocation Place all materials in a garbage container or make materials inaccessible to children Label all wires prior to disconnection ...

Page 12: ...dition la plus r_cente du Code ANSI Z223 1 ou au Canada le code CAN ACG B149 12 REMARQUE La s_cheuse est concue conform_ment au code ANSI Z 21 5 1 ou ANSI UL 2158 CAN ACG C22 2 No 112 l _dition la plus r_cente pour un USAGE DOMESTIQUE seulement Cette s_cheuse n est pas recommand_e pour utilisation commerciale comme par exemple un restaurant ou un salon de coiffure etc Pour votre s_curit_ suivre le...

Page 13: ...Prise NEMA 10 30R situ e de fat on ace que le cordon d alimentation lectrique soit accessible une fois las cheuse en place Canada prise NEMA de 14 30R NEMA 10 30R NEMA 14 30R Combin_ a veuse secheuse _ GAZ CIRCUIT D_rivation distincte de 15 A minimum avecfusible retardement ou disjoncteun ALIMENTATIONE LECTRIQUE 3ills 120 volts une phase 60 Hz courant alternatif CORDOND ALIMENTATION Lecombin_ lave...

Page 14: ...ion de charpie autour de I _vent et dans la cavite du conduit d _vacuation ONe laisser aucun mat_riau inflammable comme des v6tements des tentures des rideaux ou du papier entrer en contact avec lesconduits d _vacuation _ Auqmenter la Ionqueur du conduit riqide ou le nombre de coudes permis autableau _LONGUEURMAXIMUM_ risque de r6duire la capacite d 6vacuation du circuit Obturer lecircuit peut cr6...

Page 15: ...un rev_tement de plastique 4 Laconduited alimentation en gazDOITcomporter un robinet d arr6t distinct 5 Une prise de 0 32 cm 1 8 po NPT accessible pour le branchement d un manom_tre DOIT6tre install_e toutjuste en amont du branchement de la conduite d alimentation en gaz sur la s_cheuse 6 Lasecheuse DOIT6tre d6branch_e de la canalisation de gaz pendanttoutev_rification de pression de I alimentatio...

Page 16: ...LECTRIQUES _ RRIVEES D EAU ARRI _RE _ ANGE ARRIERE 3 3AIN _ 9 52 CM II II 27 IN _ 68 58CM 161_IN 41 27 CM TUYAU D ALIMENTATION ENGAZ ARRIERE 43 IN A 109 22 CM 41 1 4IN 104 77 CM 29 7 16 IN 74 77 CM V r 25 I 4IN _ 64 13 CM 47 36 I1161N 91 60 CM II II 30 13116IN 78 26 CM 2 1 2 IN _ 6 35CM 17 8 IN 4 76 CM 4 13 16 IN _ 12 22 CM 11 7116IN 29 5 CM ...

Page 17: ...iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii DEBALLAGE I A I aide des quatre encoignures d expedition deux de chaque c6t posez avec attention le combin_ sur le c6t gauche et enlevez la base de caoutchouc mousse Poids excessif Faites deplacer le Centre de buanderie par deux personnes ou plus 2 A I aide de la cl_ et de la douille de 3 8 po 0 96 cm enlevez le boulon d expedition e...

Page 18: ...electrique En casde doute quanta la mise a la terre ad6quate de I appareil contacter un 61ectricien agr66 Pourbrancher et mettre a laterre lasecheusea I aide d u n cordon d alimentation I La secheuse doit 6tre raise a la terre En cas de mauvais fonctionnement ou de panne la mise a la terre r6duit les risques choc 61ectrique en offrant un parcours de moindre r6sistance au courant 2 Puisque lasecheu...

Page 19: ...ENT I Faitescouler de I eau dans les robinets d eau chaude et froide pour purger lesconduites d eau et les d_barrasser des partic ules pouvant obstruer le tamis du robinet d eau 2 V_ifiez les boyaux d arriv_e d eau pour assurer que les rondelles en caoutchouc sont install_es _ chaque extremitY 3 Connectez soigneusement les boyaux d arriv_e au robinet d eau a gaunch de I appareil serrez a la main p...

Page 20: ...cheusesurun cycle complete pour en v_rifier lefonctionnement REMARQUE Dans le cas des laveusds_cheuses a gaz la conduite doit 6tre vid6e de son air avant que le brOleur ne puisse s allumer Si le brOleur ne s allume pas dans les 45 secondes qui suivent lepremierd_marrage I interrupteur de sOret_ 6teint automatiquement le brOleur Si cela se produit remettre la minuterie a OFF et attendre 5 minutes a...

Reviews: