background image

T A B L E   O F   C O N T E N T S

www.frigidaire.com   USA 1-800-944-9044

www.frigidaire.ca   Canada 1-800-265-8352

Use

 & 

Care

of your

Dehumidifier

......................................................

3
3

..............................................................

2

...............................

Care And Cleaning............................................... 9

Before You Call ................................................... 10
Major Appliance Limited Warranty ........................ 11

Normal Sounds ................................................... 9

Storage .............................................................. 9

 All

 

about the

16120100A12519

Important Safety Instructions
Location
How It Works

4

..........................................

Dehumidifier Features
Operating Instructions......................................... 4-8

Summary of Contents for FFAD3533W1

Page 1: ...1 800 265 8352 Use Care of your Dehumidifier 3 3 2 Care And Cleaning 9 Before You Call 10 Major Appliance Limited Warranty 11 Normal Sounds 9 Storage 9 All about the 16120100A12519 Important Safety Instructions Location How It Works 4 Dehumidifier Features Operating Instructions 4 8 ...

Page 2: ... grille discharge area and outlet ports Ensure that any electrical electronic equipment is one yard away from the unit Do not use or store flammable gases near the unit This dehumidifier contains no user serviceable parts Always call an authorized Electrolux servicer for repairs Do not insert or place fingers or objects into the air discharge area or back grille of the unit Do not start or stop th...

Page 3: ...dense or draw moisture from the air and air flows through the air outlet louvers into the room as dry warm air Moisture removed from air is collected in a bucket on the front of the dehumidifier The Compressor circuit has an automatic 3 minute time delayed start if the unit is turned off and on quickly This prevents overheating of the compressor and possible circuit breaker tripping Make sure the ...

Page 4: ...t If the BUCKET FULL light is on remove the bucket and re install to reset the float switch NOTE Unit must be upright for one hour prior to operating NOTE ELECTRONIC CONTROL ADJUSTS HUMIDITY DISPLAYS HUMIDITY SETS FAN SPEED TURNS UNIT ON OR OFF CHECK FILTER RESET BUTTON Before you begin thoroughly familiarize yourself with the control panel and all its functions as shown below BUCKET FULL INDICATO...

Page 5: ...5 increments 5 seconds after you have set the desired humidity the readout will display the actual room humidity If at any time you want to return to the CONTINUOUS Mode pressing the HUMIDITY button will lower the Relative Humidity through 5 decrements until the display reads CO 2 To turn the unit on press the ON OFF button The unit will run in the factory setting of CONTINUOUS and high fan speed ...

Page 6: ...Start TIMER setting First press TIMER button then adjust timer setting by tapping or holding the or button to change the delay timer at 0 5 hour increments up to 10 hours then by 1 hour increments up to 24 hours The control will count down the time remaining 8 7 5 7 etc until the unit either starts or stops For the Delay Start the fan speed and humidity maintained will be the same as previous sett...

Page 7: ...Center Removing Collected Water 1 Emptying the Bucket a When the bucket is full the unit will shut down and the BUCKET FULL indicator will illuminate 7 2019 Electrolux Home Products Inc All rights reserved 3 If the display reads E4 the communication between display PCB and main control PCB is faulty Contact your Authorized Electrolux Service Center b Do not move the unit at this time otherwise wat...

Page 8: ...ks f Direct the hose toward the drain making sure that there are no kinks that will stop the water flowing g Place the end of the hose into the drain fig 4 h Select the desired humidity setting and fan speed on the unit for continuous draining to start 1 Check the seal between the hose and the drain connector If there is a small leak then replace the hose gasket and re tighten the hose 2 It is rec...

Page 9: ...al operating conditions To remove the filter a open the back grille and pull out the filter b Wash the filter with clean water then dry c Re install the filter Normal Sounds may have a high pitched chatter Today s high efficiency compressors during the dehumidification cycle High pitched Chatter The sound of dripping water may be heard during the dehumidification cycle Dripping Sound Sound of Rush...

Page 10: ... Room temperature is too low Unit will not operate satisfactorily if the room temperature is below 41 F 5 C See Operating Conditions Refer to causes under DEHUMlDIFIER RUNS TOO MUCH Dehumidifier has been turned on recently This is normal due to refrigerant rushing through the coil Frost will usually disappear within 60 minutes Room Temperature is too low All models will operate satisfactorily at t...

Page 11: ...IOD ALLOWED BY LAW BUT NOT LESS THAN ONE YEAR ELECTROLUX SHALL NOT BE LIABLE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SUCH AS PROPERTY DAMAGE AND INCIDENTAL EXPENSES RESULTING FROM ANY BREACH OF THIS WRITTEN LIMITED WARRANTY OR ANY IMPLIED WARRANTY SOME STATES AND PROVINCES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSE QUENTIAL DAMAGES OR LIMITATIONS ON THE DURATION OF IMPLIED WAR...