Slide-In Range Specifications
•
Product Shipping Weight (approx.) – 155 Lbs.
•
Single phase 3- or 4-wire cable, 120 / 240 or 120 / 208 Volt,
60 Hertz, fused on both sides of line with ground.
(If local code
permits, range may be connected by hard-wiring or by means
of power supply cord kit.)
•
Connected Load (kW Rating) @ 240 / 208 Volts = 11.2 / 8.4 kW
•
Amps @ 240 / 208 Volts = 46.6 / 40.4 Amps
•
Recommended Circuit Breaker – 50 Amps (40 Amps minimum)
•
Always consult local and national electric codes.
•
Make sure wall coverings around range can withstand heat generated
by range.
•
Linoleum or any other synthetic floor covering located beneath range,
must be capable of withstanding minimum heat of 90° F above room
temperature without shrinking, warping or discoloring. Insulating pad
or 1/4"-thick plywood required between range and a carpeted floor.
•
Countertop MUST be level in all directions and adjustable range
height at least 1/16" greater than tallest cabinet height, to ensure
metal rangetop flange will fit properly on countertop edge.
•
When installing optional Backguard Kit, cutout depth of 21-3/4"
minimum / 22-1/8" maximum needs increased to 24".
•
Overhead cabinetry should not exceed a 13" maximum depth.
•
Absolute minimum horizontal distance between overhead cabinets
installed to either side of appliance must be no less than maximum
width of appliance.
•
Allow 24" minimum clearance between rangetop and bottom of cabinet
when bottom of wood or metal cabinet is protected by not less than
1/4" flame-retardant millboard covered with not less than No. 28 MSG
sheet steel, 0.015" stainless steel, 0.024" aluminum or 0.020" copper.
Allow 30" minimum clearance when cabinet is unprotected.
•
To reduce risk of fire when using overhead cabinetry, install
range hood that projects horizontally a recommended minimum
of 5" beyond bottom of cabinets.
Countertop Preparation
Rangetop’s side flanges overlap countertop cutout edges – for detailed
preparation instructions, refer to product installation guide on the web.
•
Flat Square-Finish Countertops –
require no preparation since
rangetop’s flange lays directly on countertop edge.
•
Formed Front-Edged Countertops –
require front molded edge to
be shaved flat 3/4" from each front corner of opening.
•
Tile Countertops –
may need trim cut back 3/4" from each front
corner of opening and /or rounded edge flattened.
•
For existing cutout width greater than 30-1/16" reduce the 3/4"
overlap dimension; for cutout width of 29", replace actual side
trim panels with smaller side trim panels, available with optional
Side Trim Kit
(refer to detailed kit installation instructions).
Note: For planning purposes only. Refer to Product Installation Guide
on the web at frigidaire.com for detailed instructions.
Optional Accessories
•
Rear Filler Kit: White – (PN # 901193-9011),
Black – (PN # 901193-9010).
•
Side Panel Kit: White – (PN # 903074-9011),
Black – (PN # 903074-9010).
•
Backguard Kit: White – (PN # 903046-9011),
Black – (PN # 903046-9010).
•
Side Trim Kit: White – (PN # 903075-9011),
Black – (PN # 903075-9010).
Slide-In Ranges
FFES3005L W/ B
30" Electric