SERVICE DATA SHEET
241588205
STANDARD - AUTOMATIC DEFROST
TOP MOUNT FREEZER - R134a
IMPORTANT SAFETY NOTE
The information provided herein is designed to assist qualified repair personnel only.
Untrained persons should not attempt to make repairs due to the possibility of electrical
shock. Disconnect power cord before servicing this appliance.
IMPORTANT
If any green grounding wires are removed during servicing, they must be returned to
their original position and properly secured.
CAUTION
All electrical parts and wiring must be shielded from torch flame. DO NOT allow
torch to touch insulation; it will char at 200°F and flash ignite (burn) at 500°F.
Excessive heat will distort the plastic liner.
NOTE
Some products come equipped with an Electronic Defrost Control. To initiate defrost,
depress the fresh food light switch 5 times in 6 seconds (light bulb must be working). To
terminate defrost, depress the fresh food light switch 5 times in 6 seconds.
PERFORMANCE DATA
NO LOAD & NO DOOR OPENINGS AT MID-POINT CONTROL SETTING
Capacitor Run or Induction Run
65°F (18°C) Ambient
90°F (32°C) Ambient
Operating Time
25 to 35%
45 to 55%
Freezer Temperature
2° to 8°F (-17° to -13°C)
0° to 5°F (-18° to -15°C)
Refrigerator Temperature
35° to 40°F (2° to 4°C)
35° to 40°F (2° to 4°C)
Low Side Pressure (cut-in)
8 to 16 psig ( 55 to 110
kPa)
8 to 16 psig (55 to 110 kPa)
Low Side Pressure (cut-out)
1 to 4 psig (7 to 28 kPa)
1 to 4 psig (7 to 28 kPa)
High Side Pressure (last 1/3
cycle)
110 to 120 psig (758 to
827 kPa)
150 to 175 psig (1034 to 1207
kPa)
Wattage (last 1/3 cycle)
140 to 185
140 to 185
Amps (running)
1.1 to 1.6
1.1 to 1.6
Base Voltage
115 vac (127 vac max)
115 vac (127 vac max)
DEFROST SPECIFICATIONS
Cabinet Size
Thermostat
Heater
Cut-in
Cut-out
Watts
Ohms
18’ & 21’
25°F
(-4°C)
47°F (8°C)
375
35
14’, 15’ & 17’
25°F (-4°C 47°F (8°C)
325
41
Mechanical Timer - Defrost 30 minutes every 10 hours of compressor run time.
Electronic Timer (ADC) - Defrost up to 24 minutes every 6-72 hours of compressor run time.
CONDENSER FAN MOTOR
Watts
RPM
Amps
2.3
1100 CW Opposite
Shaft
0.15 Running
ICE MAKER SPECIFICATIONS
Electrical
115 vac (127 vac max)
60 Hertz
Thermostat
Opens at 48°F (9°C)
Closes at 15°F ( -9°C)
Models with Orange wire close
at 8.96°F (-12.8°C)
Heater Voltage
165 vac
ICE MAKER CONNECTOR PLUG CONNECTIONS
Wire Number
Wire Color
Connects to:
1
Green / Yellow
Ground
2
Yellow
Water Valve
3
Black
Line
4
Light Blue
Neutral
IMPORTANT
PLEASE RETURN THIS SHEET TO ITS ORIGINAL LOCATION.
ICE MAKER INFORMATION
Test Cycling:
Remove cover by inserting screwdriver in notch at bottom and prying
cover from housing. Use screwdriver to rotate motor gear counterclockwise until hold-
ing switch circuit is completed. All components of ice maker should function to com-
plete the cycle.
Water Fill Volume:
The water fill adjustment screw will change the fill time. One
full turn is equal to 20cc (.68 oz.). The correct fill is 95 to 105cc (3.2 to 3.6 oz.). When
a water valve is replaced, the fill volume must be checked.