background image

Specifications  

subject to change.

Meets  

requirements of  

ASSE 1006

USA

 • 

10200 David Taylor Drive

 • 

Charlotte, NC 28262

 • 

1-800-FRIGIDAIRE

 • 

frigidaire.com

CANADA

 • 

5855 Terry Fox Way

 • 

Mississauga, ON L5V 3E4

 • 

1-800-265-8352

 • 

frigidaire.ca

*Height only adjustable to 35

3

/

4

" max. when installed in 35

3

/

4

" max.

standard cabinetry cutout. (Dimensions do NOT include insulation – 
insulation blanket may be compressed during installation.)

 33

3

/

4

// "

Adjustable

to 35

3

/

4

// "

*

Front

23

3

/

3

4

// "

Left

24

1

/

4

// "

Power supply & water inlet location 
(bottom rear)

50

1

/

4

// "

Right

 Door in 90

°

open position

27

3

/

4

// "

22

1

/

2

// "

3

1

/

2

// "

min.to 

4

1

/

2

// " max.

1"

2

1

/

4

// "

2

1

/

4

// "

**

NOTE: 

35

3

/

3

4

// "

max.

height for standard 

cabinetry cutout.

(

5

/

5

16

// " min. clearance 

required from unit to 

underside of countertop.)

3"

18"

 24"
min.

Electrical, water, 

 water

 water

and drain lines

must  be confined 

to shaded area

1

1

/

4

// "

24"

3"

90°

90°

Preferred 

drain areas

3"

 34"

min. to 

 35

3

/

3

4

// "    

  max.

  max.

**

FGCD2456Q 05/14

© 2014 Electrolux Home Products, Inc.

Dishwashers

FGCD2456Q FV/VWV/VB    

24" Built-In

Dishwasher Specifications

• 

Product Shipping Weight (approx.) – 91 Lbs.

• 

Voltage Rating – 120V>/>60 Hz>/>15 Amps 

(maximum 20 Amps if 

connected with disposer)

• 

Connected Load (kW Rating) @ 120 Volts = 1.44>kW 
(For use on adequately wired 120V, dedicated circuit having 2-wire 
service with a separate ground wire. Appliance must be grounded  
for safe operation.)

• 

Amps @ 120V = 15 Amps

• 

Always consult local and national electric & plumbing codes. 
Meets requirements of ASSE 1006>—>integral air gap on supply.

• 

Water Pressure – Hot water line to dishwasher must provide  
between 20 and 90 pounds per square inch (psi) with at least 120°>F 
hot water temperature.

• 

Make sure location has correct drain, water and electrical outlets  
to make connections.

• 

Electrical and water supplies should enter cabinet opening on floor,  
or through back or side walls, as shown in shaded areas.

• 

Keep back free of drain, water & electrical supply.

• 

Connections preferably located toward left side of dishwasher.  
Do not cross drain, water or electrical lines in front of motor, blower 
or frame.

• 

If connecting drain hose to sink trap, local code may require 
installation of Air Gap Kit 

(not included)

.

• 

Leveling legs supplied to adjust height. 

(Note: Height only adjustable 

to 35-3/4" max. when installed in 35-3/4" max. standard cabinetry 
cutout. 5/16" min. clearance required from top of unit to underside 
of countertop. Dimensions do NOT inlcude insulation — insulation 
blanket may be compressed during installation.)

• 

When installing adjacent to wall, cabinet or other obstruction that 
extends beyond front edge of unit, allow 2" minimum clearance 
between opened door and obstruction.

• 

Floor should be flat and free of obstructions with carpet removed  
to provide motor clearance.

• 

When installing at end of cabinet line, sides and back must be  
fully enclosed.

• 

Do not install unit under a cooktop, damage will occur.

• 

Recommended to seal cabinets, enclosing all sides of dishwasher, 
including underside of countertop, with oil-based paint or moisture-
proof polyurethane to prevent possible steam/moisture damage.

Note:  For planning purposes only. Refer to Product Installation Guide  

on the web at frigidaire.com for detailed instructions.

Summary of Contents for FGCD2456Q F

Page 1: ...re Hot water line to dishwasher must provide between 20 and 90 pounds per square inch psi with at least 120 F hot water temperature Make sure location has correct drain water and electrical outlets to make connections Electrical and water supplies should enter cabinet opening on floor or through back or side walls as shown in shaded areas Keep back free of drain water electrical supply Connections...

Page 2: ...delines with Side by Side Refrigerator Top Use these dimensions and clearance instructions for planning purposes only Use these dimensions and c Use these dimensions and c learance instructions for planning purposes only learance instructions for planning purposes only For detailed installation F F instructions refer to installation guide packed with product or on the web at frigidaire com Front T...

Page 3: ...ducts Inc Use these dimensions and clearance instructions for planning purposes only Use these dimensions and c Use these dimensions and c learance instructions for planning purposes only learance instructions for planning purposes only For detailed installation F F instructions refer to installation guide packed with product or on the web at frigidaire com Front Top Front Top General Installation...

Page 4: ...ucts Inc Top Use these dimensions and clearance instructions for planning purposes only Use these dimensions and c Use these dimensions and c learance instructions for planning purposes only learance instructions for planning purposes only For detailed installation F F instructions refer to installation guide packed with product or on the web at frigidaire com Front Top Front General Installation ...

Page 5: ...s Inc Use these dimensions and clearance instructions for planning purposes only Use these dimensions and c Use these dimensions and c learance instructions for planning purposes only learance instructions for planning purposes only For detailed installation F F instructions refer to installation guide packed with product or on the web at frigidaire com Front Top Front Top General Installation Gui...

Reviews: