Specifications  

subject to change.

30" Electric Single Wall Oven Specifications

 Single phase 3- or 4-wire cable, 120 / 240 or 120 / 208 Volt, 60 Hertz 

AC only electrical supply with ground required on separate circuit 

fused on both sides of line.

 For detailed electrical requirements, refer to model-specific product 

page and installation guide on web.

 Full oven base of solid plywood or similar material required, capable 

of supporting 200 Lbs.

 To adapt oven to fit cutout height greater than 28-1/8", add one 

2"-wide wood shim of appropriate height to each side of opening 

under oven side rails. Lifting oven will hide larger cutout opening 

at top and oven’s 1"-high bottom trim will hide shims at bottom. 

(Standard 1"- High Bottom Trim included.)

 To adapt oven to fit cutout height greater than 28-5/8", optional  

3"- High Bottom Trim available. 

Note:  For planning purposes only. Refer to Product Installation Guide  

on the web at frigidaire.com for detailed instructions.

30" Combination Installation Specifications

 Always consult local and national electric codes.  

(Refer to product-specific electrical specifications on this page.)

 Minimum 23-1/2" deep cutout dimension is critical for proper 

combination installation, to ensure that each built-in product’s 

faceplate will fit flush against cabinet front.

 Bases must be level and cabinet front must be square.

 Minimum 4-1/2" required distance from bottom of Wall Oven cutout 

to floor, 31" suggested.

 Respect critical dimensions as noted for proper installation of  

built-In products.

 Minimum 21" clearance needed for Wall Oven door depth when open.

30" Built-In Microwave Specifications

 For built-in installation, microwave MUST be installed with optional 

30" Trim Kit which includes Bottom Duct Assembly – shipped in 

separate box, ordered by individual part number. 

 Voltage Rating – 120V / 60 Hz / 15 or 20 Amps

 Connected Load (kW Rating) @ 120 Volts = 1.7 kW  

(For use on adequately wired 120V, dedicated circuit having 2-wire 

service with a separate ground wire. Appliance must be grounded  

for safe operation.)

 Amps @ 120 Volts = 14.3 Amps

 Full oven base of solid plywood or similar material required, capable 

of supporting 100 Lbs.

 Minimum 2-7/8" clearance required from bottom of Built-In Microwave 

cutout to top edge of Wall Oven’s faceplate, leaving a 2" visible gap 

between both product faceplates.  

USA

 • 

10200 David Taylor Drive

 • 

Charlotte, NC 28262

 • 

1-800-FRIGIDAIRE

 • 

frigidaire.com

CANADA

 

 5855 Terry Fox Way 

 Mississauga, ON L5V 3E4 

 1-800-265-8352 

 

frigidaire.ca

MOSS_EW 30INST FR 12/10 

© 2010 Electrolux Home Products, Inc. 

Printed in the U.S.A.

Summary of Contents for FGEW3045KB - 30IN SINGLE OVEN 3RD ELEMENT CONVECTION TRUE HIDDEN BAKE 8 P

Page 1: ...esswork out of convection cooking our oven does the converting for you Even Baking Technology Our latest technology ensures even baking every time Auto Oven Shut Off As an extra safety measure the oven will automatically shut off after six hours Power Broil Added power means you can broil food more evenly One Touch Self Clean Start the self cleaning cycle with just the touch of a button Quick Clea...

Page 2: ...ct Accessibility Guidelines as published by the United States Access Board on June 23 2004 as amended August 5 2005 Cutout Dimensions Height Min Max Width Min Max Depth Min 27 1 4 28 5 8 28 1 2 29 23 1 2 Product Dimensions A Height B Width C Depth D Height Wrapper E Width Wrapper Depth with Door Open 90 29 30 24 1 2 27 3 16 28 1 4 44 1 2 E D B C A Spacer Single Electric Wall Ovens Frigidaire Basel...

Page 3: ...te height to each side of opening under oven side rails Lifting oven will hide larger cutout opening at top and oven s 1 high bottom trim will hide shims at bottom Standard 1 High Bottom Trim included To adapt oven to fit cutout height greater than 28 5 8 optional 3 High Bottom Trim available Full oven base of solid plywood or similar material required capable of supporting 200 Lbs Base must be le...

Page 4: ...lectric Single Wall Oven Specifications All Frigidaire Electric Single Wall Ovens are approved to be used beneath any approved Frigidaire Gas Cooktop This installation page excludes approved wall oven model GLEB27Z7H For model specific installation details refer to Gas Cooktop Installation Over 27 Electric Single Wall Oven GLEB27Z7H Specifications pages on web For detailed Gas Cooktop installation...

Page 5: ...ommodate the depth of approved electric cooktop models To route armored cable to junction box cut minimum 4 x 4 opening in right side filler panel Allow 4 1 2 maximum height from oven base to floor if cooktop is installed directly over wall oven Note For planning purposes only Refer to Product Installation Guide on the web at frigidaire com for detailed instructions excludes side swing wall oven C...

Page 6: ... dimension is critical for proper combination installation to ensure that each built in product s faceplate will fit flush against cabinet front Bases must be level and cabinet front must be square Minimum 4 1 2 required distance from bottom of Wall Oven cutout to floor 31 suggested Respect critical dimensions as noted for proper installation of built In products Minimum 21 clearance needed for Wa...

Page 7: ...ension is critical for proper combination installation to ensure that each built in product s faceplate will fit flush against cabinet front Bases must be level and cabinet front must be square Minimum 4 1 2 required distance from bottom of Warmer Drawer cutout to floor Respect critical dimensions as noted for proper installation of built In products Minimum 21 clearance needed for Wall Oven door ...

Page 8: ...8352 frigidaire ca INSTGDLNS_SSR FR 10 10 2010 Electrolux Home Products Inc Printed in the U S A General Installation Guidelines with Side by Side Refrigerator Top Use these dimensions and clearance instructions for planning purposes only For detailed installation instructions refer to installation guide packed with product or on the web at frigidaire com Front Top Front ...

Page 9: ...5 8352 frigidaire ca INSTGDLNS_TMR FR 10 10 2010 Electrolux Home Products Inc Printed in the U S A Use these dimensions and clearance instructions for planning purposes only For detailed installation instructions refer to installation guide packed with product or on the web at frigidaire com Front Top Front Top General Installation Guidelines with Top Mount Refrigerator ...

Reviews: