30" GAS RANGE INSTALLATION INSTRUCTIONS

(For gas venturi models with electric ignition)

 

Do not use flame to check for gas leaks.

Checking Manifold Gas Pressure

Disconnect the range and its individual shut-off valve from the
gas supply piping system during any pressure testing of that
system at test pressures greater than 14" of water column
pressure (approximately 1/2" psig).

The appliance must be isolated from the gas supply piping
system by closing its individual manual shut-off valve during
any pressure testing of the gas supply piping system at test
pressures equal to or less than 14" of water column pressure
(approximately 1/2" psig).

If it should be necessary to check the manifold gas pressure,
connect manometer (water gauge) or other pressure device to
the top burner right rear orifice.  Using a rubber hose with inside
diameter of approximately 1/4," hold tubing down tight over
orifice.  Turn burner valve on.

For an accurate pressure check have at least two (2) other top
burners burning. Be sure the gas supply (inlet) pressure is at
least one inch above specified range manifold pressure. The
gas supply pressure should never be over 14" water column.
When properly adjusted for Natural Gas the manifold pressure
is 4." (For LP/Propane Gas the manifold pressure is 10.")

 DO NOT allow regulator to turn on pipe

when tightening fittings.

a)

Install an external manual gas shut-off valve to gas supply
line in an accessible location outside of the range. Be sure
you know where and how to shut off the gas supply to the
range.

b)

Install 1/2" flare union adapter to pressure regulator using

NO MORE THAN 15ft./lbs.

 of torque

NOTE:

 Be sure to 

stabilize

 the left side of the pressure

regulator with  adjustable wrench before tightening  ANY
fittings to the pressure regulator (Refer to Fig. 4d).

c)

Tighten the gas supply fitting and/or appliance conduit to
flare union on the right side of the pressure regulator  using

NO MORE THAN 15ft./lbs.

 of torque.Be sure to 

stabilize

“ ON ”

Fig. 4d

Fig. 4e

Fig. 4f

the 1/2" flare union adapter with an adjustable wrench
before tightening  the gas supply fitting and/or appliance
conduit (Refer to Fig. 4e).

d)

Install flare union adapter to external manual shut-off valve.

e)

Attach appliance conduit to flare union on shut-off valve.

f)

Make sure service shut-off valve on pressure regulator
is in the "ON" position 

(See Fig. 4f).

g)

Check for leaks. Turn the gas supply on to the range and
use a liquid leak detector at all joints and conduits to
check for leaks in the system.

Summary of Contents for FGF303LW

Page 1: ...iththerangeorobtainedfromyourdealer Follow all instructions provided with the LP Conversion Kit Español Páginas9 16 If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or death FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YO...

Page 2: ...children alone or unattended in the area where an appliance is in use As children grow teachthemtheproper safeuseofallappliances Neverleave the oven door open when the range is unattended Stepping leaning or sitting on the doors ordrawersofthisrangecanresultinseriousinjuriesand can also cause damage to the range Do not store items of interest to children in the cabinets above the range Children co...

Page 3: ...ip brackets must also be moved and installed with the range Instructions are provided for installation in wood or cement fastened to either the floor or wall When installed to the wall make sure that screws completely penetrate dry wall and are secured in wood or metal When fastening to the floor or wall be sure that screws do not penetrate electrical wiring or plumbing A LocatetheBracketUsingtheT...

Page 4: ...nd ventilation air For proper operation the maximum inlet pressure to the regulator should be no more than 14 inches of water column pressure The inlet pressure to the regulator must be at least 1 inch greater than regulator manifold pressure Examples If regulator is set for natural gas 4 inch manifold pressure inlet pressure must be at least 5 inches if regulator has been convertedforLP Propanega...

Page 5: ...ever be over 14 water column WhenproperlyadjustedforNaturalGasthemanifoldpressure is 4 For LP Propane Gas the manifold pressure is 10 DO NOT allow regulator to turn on pipe when tightening fittings a Installanexternalmanualgasshut offvalvetogassupply lineinanaccessiblelocationoutsideoftherange Besure you know where and how to shut off the gas supply to the range b Install1 2 flareunionadaptertopre...

Page 6: ...s Becauseofpotentialsafetyhazardsundercertainconditions we strongly recommend against the use of any extension cord However if you still elect to use an extension cord it is absolutely necessary that it be a UL listed 3 wire grounding type appliance extension cord and that the current carrying rating of the cord in amperes be equivalent to or greater than thebranchcircuitrating Suchextensioncordsa...

Page 7: ...s the electrically controlled oven valve will open and flame will appear at the oven burner There is a time lapse from 30 to 60 seconds after the thermostat is turned ON before the flame appears at the oven burner When the oven reaches the dial setting the glowing igniter will go off The burner flame will go out in 20 to 30 seconds after the igniter goes OFF To maintain any given oven temperature ...

Page 8: ...d expense The list includes common occurrences that are not the result of defective workmanship or materials in this appliance Refer to the warranty in your Owner s Guide for our toll free service number and address Please call or writeifyouhaveinquiriesaboutyourrangeproductand or need to order parts Care Cleaning and Maintenance Refer to the Owner s Guide for operating and cleaning instructions I...

Reviews: