FGGF301DN F/ W/ B    

30" Gas

Freestanding Range Specifications

 Product Shipping Weight (approx.) – 260 Lbs.

 Voltage Rating – 120V / 60 Hz / 15 Amp

 Connected Load (kW Rating) @ 120 Volts = 1.8 kW  

(For use on adequately wired 120V, dedicated circuit having 2-wire 

service with a separate ground wire. Appliance must be grounded  

for safe operation.)

 Amps @ 120 Volts = 15 Amps

 Always consult local and national electric and gas codes.

 Make sure wall coverings around range can withstand heat generated 

by range.

 Linoleum or any other synthetic floor covering located beneath range, 

must be capable of withstanding minimum heat of 90° F above room 

temperature without shrinking, warping or discoloring. Insulating pad 

or 1/4"-thick plywood required between range and a carpeted floor.

 Do not obstruct flow of combustion air at oven vent nor around base 

or beneath lower front panel of range. Range requires fresh air for 

proper burner combustion.

 Do not install range beneath any downward-blowing, overhead vent 

hood or air curtain.

 Range ships with 1/2" NPT factory regulator.

 LP Gas Conversion Kit supplied.

 Overhead cabinetry should not exceed a 13" maximum depth.

 Allow 30" minimum clearance between top of cooking surface and 

bottom of unprotected wood or metal overhead cabinet; or 24" 

minimum clearance when bottom of wood or metal overhead cabinet 

is protected by not less than 1/4" flame-retardant millboard covered 

with not less than No. 28 MSG sheet steel, 0.015" stainless steel, 

0.024" aluminum or 0.020" copper.

 Absolute minimum horizontal distance between overhead cabinets 

installed to either side of appliance must be no less than maximum 

width of appliance.

 Range can be installed flush to wall with 0" minimum rear clearance.

 Minimum 7" clearance required from edge of rangetop to nearest 

combustible wall on either side of range above 36" height.

 To reduce risk of fire when using overhead cabinetry, install vent hood 

that projects horizontally a recommended minimum of 5" beyond 

bottom of cabinets.

 Follow all dimension requirements provided to prevent property 

damage, potential fire hazard, and incorrect countertop and  

cabinet cuts.

Note:  For planning purposes only. Refer to Product Installation Guide  

on the web at frigidaire.com for detailed instructions.

30" Gas Freestanding Ranges with Double Ovens (Upper)

Gallery

Summary of Contents for FGGF301DN F

Page 1: ...0 Depth Including Handle 28 5 16 More Easy To Use Features Keep Warm Setting Keep food warm until everything and everyone is ready Smudge Proof Stainless Steel1 Real Stainless Steel with a protective coating reduces fingerprints and smudges so it s easy to clean Even Baking Technology Our latest technology ensures even baking every time Even Broil Greater flame coverage means you can broil food mo...

Page 2: ... Convection Quick Preheat Effortless Temperature Probe My Favorite Chicken Nugget Button Pizza Button Keep Warm Add a Minute Delay Start Self Clean Quick Clean Option Delay Clean Kitchen Timer Timed Cook Option Auto Oven Shutoff Oven Lock Out Cooktop Features Right Front Burner BTU Right Rear Burner BTU Left Front Burner BTU Left Rear Burner BTU Center Extra Zone Burner BTU Oven Features Upper Low...

Page 3: ... proper burner combustion Do not install range beneath any downward blowing overhead vent hood or air curtain Range ships with 1 2 NPT factory regulator LP Gas Conversion Kit supplied Overhead cabinetry should not exceed a 13 maximum depth Allow 30 minimum clearance between top of cooking surface and bottom of unprotected wood or metal overhead cabinet or 24 minimum clearance when bottom of wood o...

Page 4: ... 1 800 265 8352 frigidaire ca INSTGDLNS_SSR FR 02 12 2012 Electrolux Home Products Inc General Installation Guidelines with Side by Side Refrigerator Top Use these dimensions and clearance instructions for planning purposes only For detailed installation instructions refer to installation guide packed with product or on the web at frigidaire com Front Top Front ...

Page 5: ...4 1 800 265 8352 frigidaire ca INSTGDLNS_TMR FR 02 12 2012 Electrolux Home Products Inc Use these dimensions and clearance instructions for planning purposes only For detailed installation instructions refer to installation guide packed with product or on the web at frigidaire com Front Top Front Top General Installation Guidelines with Top Mount Refrigerator ...

Page 6: ... 1 800 265 8352 frigidaire ca INSTGDLNS_FDR FR 02 12 2012 Electrolux Home Products Inc Top Use these dimensions and clearance instructions for planning purposes only For detailed installation instructions refer to installation guide packed with product or on the web at frigidaire com Front Top Front General Installation Guidelines with French Door Refrigerator ...

Reviews: