LIST OF MATERIALS

LIST OF MATERIALS

 

Parts included in your hood

4 - 0.45 x 1.3 cm mounting screws

” x 10” (8.3 x 25.4 cm) rectangular metal vent

 

  system. 

NOTE:

 An optional 7” round duct kit is available. 

You can 

order this kit as part number 5304487139

.

Parts Needed

2 - UL listed wire connectors

1 - 75W max, 120V incandescent light bulb

Wall or roof cap with damper to match vent system

Vent clamps/duct tape as required 

UL listed or CSA approved ½” strain relief

 

Tools/Materials required

Drill

1¼” (3.0 cm) drill bit

⅛” (0.3 cm) drill bit for pilot holes

Pencil

Wire stripper or utility knife

Tape measure or ruler

Caulking gun and weatherproof  

  caulking compound

Flat-blade screwdriver

Phillips screwdriver

Saber or keyhole saw 

 

For cabinets with recessed bottoms:

Two 2” (5.1 cm) wide filler strips. Length and

 

  thickness determined by recess dimensions.

Four flat head wood screws or machine screws

 

  with washers and nuts (to attach filler strips).














ELECTRICAL REQUIREMENTS 

 

Observe all governing codes and ordinances.

Ensure that the electrical installation is adequate and in 

conformance with National Electrical Code, ANSI/NFPA 

70 (latest edition), or CSA Standards C22.1-94, Canadian 

Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edi-

tion) and all local codes and ordinances.

If codes permit and a separate ground wire is used, it is 

recommended that a qualified electrician determine that 

the ground path is adequate.

A copy of the above code standards can be obtained 

from:

National Fire Protection Association

One Batterymarch Park

Quincy, MA 02269

CSA International

8501 East Pleasant Valley Road

Cleveland, OH 44131-5575

A 120 volt, 60 Hz., AC only, 15-amp, fused  

  electrical circuit is required.

If the house has aluminum wiring, follow the  

  procedure below:

Connect a section of solid copper wire to the  

  pigtail leads.

Connect the aluminum wiring to the added 

  section of copper wire using special co 

 

  nectors and/or tools designed and UL listed 

  for joining copper to aluminum.

Follow the electrical connector manufacturer’s recom-

mended procedure. Aluminum/copper connection must 

conform with local codes and industry accepted wiring 

practices.

Wire sizes and connections must conform with 

  the rating of the appliance as specified on the

 

  model/serial rating plate. 

  The model/serial plate is located on the left side of 

  the range hood.

Wire sizes must conform to the requirements of 

  the National Electrical Code, ANSI/NFPA 70 (la 

  est edition), or CSA Standards C22. 1-94, Canad 

  an Electrical Code, Part 1 and C22.2 No. 0-M91 

  (latest edition) and all local codes and ordinances.

1.

.

Summary of Contents for FHWC3025

Page 1: ...USA 1 800 944 9044 www frigidaire com Canada 1 800 265 8352 www frigidaire ca LI30KC 316902495 May 13 ...

Page 2: ...ome common problems that might occur If you do need service help is only a phone call away Call Frigidaire Customer Services at 1 800 944 9044 Product Registration Registering your product with Frigidaire enhances our ability to serve you You can register online at www frigidaire com or by dropping your Product Registration Card in the mail Serial Plate Location Serial plate location Find it on th...

Page 3: ...facturer If you have questions contact the manufacturer Before servicing or cleaning the unit switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Installation Work and Electrical Wiring Must...

Page 4: ...fingers and loose clothing The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation maintenance and suitable use of the product The manufacturer further declines all respon sibility for injury due to negligence and the warranty of the unit automatically expires due to improper mainte nance a b c d 1 2 3 4 IMPORTANT SAFETY INSTRUCT...

Page 5: ...Code Part 1 and C22 2 No 0 M91 latest edi tion and all local codes and ordinances If codes permit and a separate ground wire is used it is recommended that a qualified electrician determine that the ground path is adequate A copy of the above code standards can be obtained from National Fire Protection Association One Batterymarch Park Quincy MA 02269 CSA International 8501 East Pleasant Valley Ro...

Page 6: ...the Manufactured Home Construction Safety Standards Title 24 CFR Part 328 formerly the Federal Standard for Mobile Home Construction and Safety Title 24 HUD Part 280 or when such standard is not applicable the stan dard for Manufactured Home Installation 1982 Manu factured Home Sites Communities and Setups ANSI A225 1 NFPA 501A or latest edition or with local codes Cabinet Dimensions A 66 167 cm s...

Page 7: ...up Air Local building codes may require the use of makeup air systems when using ventilation systems greater than specified CFM of air movement The specified CFM varies from locale to locale Consult your HVAC professional for specific requirements in your area Venting Methods Vent system can terminate either through the roof or wall Use 3 x 10 8 3 x 25 4 cm rectangular with a maximum vent length o...

Page 8: ... mark a vertical centerline on the wall and cabinet bottom 1 4 1 A A Centerline Wood filler strips recessed cabinet bottoms only Wall Cabinet bottom 3 7 6 cm 3 7 6 cm 4 5 x 13 mm mounting screws VENTING REQUIREMENTS 3 x 10 8 3 cm x 25 4 cm Vent System Vent Piece 3 x 10 8 3 cm x 25 4 cm 5 0 ft 90 elbow 1 5 m 3 x 10 8 3 cm x 25 4 cm 12 0 ft flat elbow 3 7 m 3 x 10 8 3 cm x 25 4 cm 0 0 ft wall cap 0 ...

Page 9: ...m Roof Venting To make a 4 x 10 10 16 cm x 26 7 cm rectangular cutout on the underside of cabinet top and bottom Mark lines 1 3 cm and 4 12 1 cm from the back wall on the centerline of the underside of cabinet Mark lines 5 13 3 cm to the right and left of the centerline on the underside of cabinet Use saber or keyhole saw to cut a rectangular opening for vent Repeat steps 1 3 for the underside of ...

Page 10: ... LOCATION Style 3 Cut Openings for 3 x 10 8 3 x 25 4 cm Rectangular Vent Transition to Round Vent Roof Venting To make a circular vent opening on the underside of the cabinet top Mark a centerline on the underside of the top of cabinet Mark a line 5 12 7 cm from the back wall on the underside of the top of cabinet Use a compass or a circle template to draw a circle with a diameter of 7 19 cm Use s...

Page 11: ...er supply cable according to the National Electric Code or CSA standards and local codes and ordinances There must be enough wiring from the fused disconnect or circuit breaker box to make the connection in the hood electrical terminal box NOTE Do not reconnect power until the installation is complete Remove the screw from the terminal box cover Remove terminal box cover and set aside Remove the p...

Page 12: ...rical Shock Hazard Disconnect power before servicing Replace all parts and panels before operating Failure to do so can result in death or electrical shock 1 Disconnect power 2 Use UL listed wire connectors and connect white wires A together 3 Use UL listed wire connectors and connect black wires B together WARNING Fire Hazard Electrically ground the blower Use copper wire Connect ground wire to g...

Page 13: ...ver NOTE For installations which are venting out the roof or wall the recirculating vent cover must remain in place Do not remove as unit will not perform properly To complete the installation go to Make Electrical Connection section on page 11 4 RANGE HOOD USE The range hood is designed to remove smoke cooking vapors and odors from the cooktop area For best results start the hood before cooking a...

Page 14: ... Replace the old charcoal filter with a new charcoal filter 4 1 4 A A Filter screw RANGE HOOD CARE A B A Light bulb socket B Lens cover Cleaning WARNING To Reduce The Risk Of Fire Or Electrical shock disconnect from power supply before cleaning IMPORTANT Clean the hood and grease filters frequently according to the following instructions Replace grease filter before operating hood IMPORTANT Exteri...

Page 15: ...ed in place 3 Check the installation of the hood The motor is working but the lights are not 1 Defective bulb 1 Change the bulb 2 The light bulb is loose 2 Tighten the light bulb 3 The wires on the light switch are loose 3 Make sure the wires on light switch are connected properly The hood is not venting out properly 1 The hood might be hanging to high from the cook top 1 Adjust the distance betwe...

Page 16: ...ding the state of Alaska 13 14 Damages caused by services performed by unauthorized service companies use of parts other than genuine Electrolux parts or parts obtained from persons other than authorized service companies or external causes such DISCLAIMER OF IMPLIED WARRANTIES LIMITATION OF REMEDIES CUSTOMER S SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY SHALL BE REPAIR OR REPLACEMENT AS...

Page 17: ...printed in Mexico ...