8
PREPARE THE LOCATION
NOTE
Before making cutouts, make sure there is
proper clearance within the ceiling or wall.
Disconnect power.
Select a flat surface for assembling the range hood.
Place covering over that surface.
Lift the range hood and set it upside down onto covered
surface.
If cabinet has recessed bottom, add wood filler strips
on each side. Install screws to attach filler strips in
locations shown.
Determine Wiring Hole Location
Determine and clearly mark a vertical centerline on
the wall and cabinet bottom.
1.
.
.
4.
1.
A
A Centerline
Wood filler strips
(recessed cabinet
bottoms only)
Wall
Cabinet
bottom
3” (7.6 cm)
3” (7.6 cm)
4.5 x 13 mm
mounting screws
VENTING REQUIREMENTS
¼
” x 10” (8.3 cm x 25.4 cm) Vent System
Vent Piece
3¼
” x 10” (8.3 cm x 25.4 cm)
5.0 ft
90° elbow
(1.5 m)
3¼
” x 10” (8.3 cm x 25.4 cm)
12.0 ft
flat elbow
(3.7 m)
3¼
” x 10” (8.3 cm x 25.4 cm)
0.0 ft
wall cap
(0.0 m)
Example Vent System
Maximum Recommended Length
= 35 ft (10.7 m)
1 - 90° elbow
= 5.0 ft (1.5 m)
8 ft (2.4 m) straight
= 8.0 ft (2.4 m)
1 - wall cap
= 0.0 ft (0.0 m)
Length of 3¼
” x 10”
= 13.0 ft (3.9 m)
(8.3 cm x 25.4 cm) system
2 ft
(0.6 m)
3¼
” x 10”
(8.3 x 25.4 cm)
elbow
6 ft (1.8 m)
Wall Cap
Summary of Contents for FHWC3025
Page 17: ...printed in Mexico ...