background image

Use & care guide

Guia de uso y cuidado

Guide d’utilisation et d’entretien

30” and 36” Range Hood

FHWC3 FHWC3660LSA

00-Elux FHWC3060LSA-Range hood-Book-01.indd   1

6/16/11   13:49 PM

316902443   Rev A   February 2012

Summary of Contents for FHWC3060LSA

Page 1: ...Use care guide Guia de uso y cuidado Guide d utilisation et d entretien 30 and 36 Range Hood FHWC3060LSA FHWC3660LSA 316902443 Rev A February 2012 ...

Page 2: ...o serve you You can register online at www frigidaire com or by dropping your Product Registration Card in the mail Questions For toll free telephone support in the U S 1 800 944 9044 or Canada 1 800 265 8352 For online support and Internet production information visit http www frigidaire com Important safety instructions Do not attempt to install or operate this appliance until you have read the ...

Page 3: ...ntended by the manufacturer If you have questions contact the manufacturer Installation work and electrical wiring must bedonebyqualifiedperson s inaccordance with a ll applicable codes standards including fire rated construction Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equi...

Page 4: ...er or the electric element Be careful to prevent burns If the flames do not go out immediately evacuate and call the fire department Never pick up a flaming pan you may be burned Do not use water including wet dishcloths or towels a violent steam explosion will result Use an extinguisher only if You know you have a class ABC extinguisher and you already know how to operate it The fire is small and...

Page 5: ...rotection Association Batterymarch Park Quincy Massachusetts 02269 CSA International 8501 East Pleasant Valley Road Cleveland Ohio 44131 5575 Power requirement 120V 60Hz 15 or 20A branch circuit Intended use Yourrangehoodisintendedforexhaustoperation only This range hood is not recommended to be used over indoor grills Do not use it to exhaust hazardous or explosive materials or vapors Parts suppl...

Page 6: ... at the exterior opening not delivered This can be installed by the professional that performs the wall breakthrough If open are operated in the same room ask your local chimney sweeper about the local regulations prior to installation If you are renting then approval must be obtained from the owner of the property Attention In order for the range hood to reach optimal performance install it over ...

Page 7: ...all two horizontal supports at least 1 x 6 between two wall studs at the bottom and top mounting holes installation location fig The horizontal support must be flush with the room side of the studs Use cleats behind both sides of the support to secure to wall studs Reinstall drywall and refinish fig IMPORTANT Framing must be capable of supporting 100 lbs Step 1 Make sure that no cables or pipes wi...

Page 8: ...rews depending on the wall type Wall type Required screws Wood 4 wood screws 14 Brick Concrete 4 long screws 10 Insert 2 screws 10 or 14 in the top location but do not fully insert the screws fig Mount the range hood 1 to the wall and tighten the screws Insert and tighten the 2 remaining screws on the bottom location of the range hood fig Attach the collar 6 to the range hood 1 Secure with 2 short...

Page 9: ... fig fig Connect the incoming positive neutral and ground cables to the respective terminals The ground cable is already pre assembled onto the junction box to provide grounding fig fig L live Black ground Green N neutral White L N Mount the junction box onto the range hood using 2 short screws 15 fig fig Step 6 Insert the upper chimney 3 into the lower chimney 3 from top to bottom fig Mount upper...

Page 10: ... burning gas or other fuels not applicable to appliances that only discharge the air back into the room The air must not be discharged into a flue that is used for exhausting fumes from appliances burning gas or other fuels not applicable to appliances that only discharge the air back into the room Air recirculation operation Recirculated air Kitchen fumes are removed and after purification are fe...

Page 11: ...s grease smoke and dust so the filter is directly affecting the efficiency of the range hood If not cleaned the grease residue potential flammable will saturate on the filter Clean it with household cleaning detergent The filter is dishwasher safe Recirculator clean the ventilation openings on the top sides every 4 6 months Charcoal filters If the model is not vented to the outside the air will be...

Page 12: ...n but fan does not work The fan blade is jammed The motor is damaged Both light and fan do not work Light bulb broken Replace with a bulb with correct rating Problem with electrical connection Check the electrical connection with an electrician Suction performance is not good Distance between the appliance and the cooking place too large Readjust the distance page 7 fig and table below Metallic an...

Page 13: ...ons other than authorized service companies or external causes such as abuse misuse inadequate power supply accidents fires or acts of God Warranty information USA 1 800 944 9044 Electrolux Major Appliances North America 10200 David Taylor Drive Charlotte NC 28262 Canada 1 800 265 8352 Electrolux Canada Corp 5855 Terry Fox Way Mississauga Ontario Canada L5V 3E4 DISCLAIMER OF IMPLIED WARRANTIES LIM...