CONNECTOR HOOKUP
Pressure
regulator
Gas Flow into Cooker
Gas Flow into Cooker
Flex
connector
(6
ft.
max.)
Adapter
Installer: Inform the consumer of the location of the gas shut-off valve.
1/2”
or
3/4”
Gas pipe
Adapter
Gas
shut-off
valve
Pressure
regulator
Elbow
Elbow
Nipple
Union
Nipple
Gas
shut-off
valve
1/2” or 3/4”
Gas pipe
Flexible
Option
Rigid Pipe
Option
1
GAS SUPPLY
Fire Hazard: Do not use a
flame to check for gas leaks.
Explosion Hazard: Do not
exceed 25 ft-lbs of torque when making gas
line connections. Overtightening may crack
the pressure regulator resulting in fire or
explosion hazard.
Gas Pressure Regulator
You must use the gas pressure regulator supplied
with this cooker. For proper operations the inlet
pressure to the regulator should be as follows:
Natural Gas:
Minimum pressure:
6”
of Water Column
Maximum pressure:
13”
of Water Column
LP Gas:
Minimum pressure:
11”
of Water Column
Maximum pressure:
13”
of Water Column
If you are not sure about the inlet pressure
contact local gas supplier.
Shut off the main gas supply valve before
disconnecting the old cooker and leave it off
until the new hook-up has been completed.
Don’t forget to relight the pilot on other gas
appliances when you turn the gas back on.
Because hard piping restricts movement of
the cooker, the use of a CSA International-
certified flexible metal appliance connector is
recommended unless local codes require a hard-
piped connection.
If the hard piping method is used, you must
carefully align the pipe; the cooker cannot be
moved after the connection is made.
To prevent gas leaks, put pipe joint compound on,
or wrap pipe thread tape with Teflon* around, all
male (external) pipe threads.
A. Install a manual shut-off valve in the gas line
in an easily accessed location outside of the
cooker. Make sure everyone operating the
cooker knows where and how to shut off the
gas supply to the cooker.
B.
Install male 1/2” flare union adapter to the 1/2”
NPT internal thread at inlet of regulator. Use a
backup wrench on the regulator fitting to avoid
damage.
C.
Install male 1/2” or 3/4” flare union adapter to
the NPT internal thread of the manual shut-off
valve, taking care to back-up the shut-off valve
to keep it from turning.
D. Connect flexible metal appliance connector
to the adapter on the cooker. Position cooker to
permit connection at the shut-off valve.
E. When all connections have been made, make
sure all cooker controls are in the off position
and turn on the main gas supply valve.
Use a liquid leak detector at all joints and
connections to check for leaks in the system.
When using pressures greater than 1/2 psig
to pressure test the gas supply system of the
residence, disconnect the cooker and individual
shut-off valve from the gas supply piping. When
using pressures of 1/2 psig or less to pressure
test the gas supply system, simply isolate the
cooker from the gas supply system by closing the
individual shut-off valve.
When checking for proper operation of the
regulator, the inlet pressure must be at least 1”
greater than the operating (manifold) pressure as
given on rating label of product.
*Teflon: Registered trademark of DuPont